Contact Us

HXN40011

Brand: Hisiwell
Hisiwell HXN40011 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXN40011 — Discrete & Power Semiconductors | Superb Automation

HXN40011

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXN40011 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXN40011: 56 dBm from a 50 V rail in 1 ms pulses

The HXN40011 is the top of the 1.2 to 1.4 GHz ladder in this vendor's table. It delivers at least 56 dBm of saturation power, at least 13 dB of gain and 50 per cent efficiency marked as a typical rather than a floor, from a 50 V drain, with plus or minus 0.8 dB of flatness and 1 ms pulses at 10 per cent duty. Fifty six dBm is 398.1 W, which is four hundred watts from a single internally matched device.

Fifty volts is what makes four hundred watts possible at a sane current. At 50 per cent efficiency the DC input at saturation is 796.2 W, the drain current is 15.92 A and the heat is 398.1 W. At 10 per cent duty the average DC input is 79.6 W, the average drain current is 1.59 A and the average dissipation is 39.8 W, which is a heatsink problem rather than a cooling plant problem. Compare that with a 126 W continuous wave member on 32 V, whose average dissipation is the full 126 W: the pulsed 50 V part dissipates less on average than a continuous wave part at a third of the output.

Fifty volts is also the number that decides the DC feed. A 400 W pulse at 15.92 A needs a supply with enough stored energy to hold the rail for a millisecond without droop, and a 50 V rail has 100 microfarads at 0.6 J of stored energy, against a pulse that draws 0.8 J. The capacitor bank, not the supply, delivers a pulse of this size, and that fact shapes the whole power distribution of the transmitter.

The drive for 56 dBm at 13 dB of gain is 43 dBm, or 19.95 W. That is above the 40 dBm saturation output of the smallest member of the family, so a 400 W stage is driven by a 48 or 51 dBm device, and the chain to a 400 W output is three power stages. Efficiency printed as a typical rather than a floor means the 50 per cent should be read as what a good part does, not as what every part guarantees.

The parameter rows the vendor publishes

Part classGallium nitride power transistor with internal matching
Frequency range1.2 to 1.4 GHz
Saturation power as publishedat least 56 dBm
Saturation power in watts, calculated398.1 W
Gain as publishedat least 13 dB
Efficiency as published50 per cent typical
Output at 1 dB compressionnot published
Input impedance50 ohm
Output impedance50 ohm
Drain voltage50 V
Flatness across the bandplus or minus 0.8 dB
Operating modepulsed, 1 ms at 10 per cent duty
DC input at saturation during the pulse, calculated796.2 W
Dissipation during the pulse, calculated398.1 W
Drain current during the pulse, calculated15.92 A
Average DC input at 10 per cent duty, calculated79.6 W
Average dissipation at 10 per cent duty, calculated39.8 W
Average drain current at 10 per cent duty, calculated1.59 A
Energy drawn per 1 ms pulse, calculated0.8 J
Drive power for rated output, calculated43 dBm, 19.95 W
Droop across the pulsenot published
Maximum pulse width and duty cycle1 ms at 10 per cent as published
Matching technologyin-plane matching synthesis on a film hybrid carrier
Stated applicationRF and microwave systems
Package and flangenot published on the parameter page
Thermal resistancenot published
Transient thermal impedancenot published
Scattering parametersnot published
Orderable addendumnot published
Member below, same band, pulsedHXN40010 at 53 dBm from 28 V
Member below, same band, continuous waveHXN40009 at 51 dBm from 32 V
Same output, higher bandHXN40023 at 56 dBm over 1.9 to 2.1 GHz from 50 V
Same output, lower bandHXN40005 at 56 dBm over 0.9 to 1.2 GHz from 50 V

Where 400 W in a millisecond goes

Inside the pulse the die has to move 398 W of heat, and a millisecond is long enough for that heat to reach the die attach and the flange. The transient thermal impedance at 1 ms for a device of this size is typically a few degrees per watt, which at 398 W is a rise of several hundred degrees if the die heats alone. The real number comes from the pulse width and the area of the die, and the vendor publishes neither, so a 400 W pulse cannot be cleared on this page.

The average is the part that can be computed. At 10 per cent duty the dissipation is 39.8 W, and a carrier plus interface plus heatsink of 1.2 C per watt gives 48 C of rise, so a 60 C cabinet holds the average junction at 108 C and leaves room for the pulse transient on top. That is how these devices are normally specified: an average junction well below the limit so that the peak inside the pulse lands inside it.

There is a second thermal path that is easy to forget. The internal match sits on the same carrier as the die, and it dissipates a share of the output that grows with frequency. At 400 W and 1.4 GHz the match loss is a real term in the heat budget and it is included in the 50 per cent efficiency row rather than added to it, which is why the measured carrier temperature at the band edges often runs higher than the centre frequency arithmetic predicts.

Where the datasheet stops and the bench starts

No transient thermal impedance, no droop, no compression point and no small signal data, as on every member of the family, and for a 400 W pulsed part the missing transient impedance is the difference between a cleared build and a guess. No bias information is given either, and at 50 V the gate sequencing and the drain clamp are not optional details.

There is also no statement of what happens when the load reflects. A 400 W stage feeding an antenna sees a mismatch in the field, and a part with no published load mismatch tolerance has to be protected by an isolator or a circulator, which at this power level is a substantial piece of hardware that belongs in the mechanical budget from the start.

The efficiency is marked typical, which is a fair description of a 50 V GaN device at 1.4 GHz, but it means the 50 per cent cannot be used as a guaranteed floor in a thermal calculation. Planning at 45 per cent adds 88 W of DC input at the same output and changes the capacitor bank and the average heat.

Where a 400 W pulsed L band part still fits

It fits a high power pulsed transmitter with a 50 V rail: a radar or a long range data link, a ground based illumination source, or a laboratory amplifier for high power testing. It fits any system where the 10 per cent duty is fixed by the waveform, because at that duty the average heat is only 40 W and a conventional heatsink is enough.

It does not fit a continuous wave system at all, and it does not fit a system whose waveform can drift above 10 per cent duty, since the average heat scales directly with duty and there is no derating curve to consult. It does not fit a 28 V platform, where the 53 dBm member is the correct part, and it does not fit a linear application with a high peak to average ratio.

Our RF power transistor cross reference work keeps the rail, the duty cycle, the flange and the drive level per approved alternate, and at 400 W the flange row is as important as the electrical ones. A device that normally enters a programme with a specified screening level also needs a traceability route, which we quote with the part rather than after a first article.

Questions we answer before an order is placed

The first is the rail and the stored energy, since a 1 ms pulse at 15.92 A draws 0.8 J and the capacitor bank, not the supply, delivers it. The second is the drive chain, at 43 dBm, which is a 20 W stage and therefore two power stages below the final device. The third is the load mismatch protection, because a 400 W stage without an isolator is one antenna fault away from a failure.

The fourth is the screening and the documentation. At this power level a part normally enters with a specified screening level, a serialised record and a thermal data sheet, and none of that is on the vendor page. Our incoming inspection plan records what each delivered lot actually carries against the purchase order, and the kit for a stage this size, with the circulator, the coupler and the capacitors, is quoted together with the device.