HXC50125
Product Specifications
HXC50125
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HXC50125 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HXC50125: 500 W per side on HF to 300 MHz and the first row where the window starts to bite
The HXC50125 is an LDMOS RF power transistor from Hisiwell on the HF table with a 0.3 GHz top frequency and a 500 times two output row. One kilowatt total, 60.00 dBm exactly, from a 50 V rail in CW. It is the middle rung of the pair ladder on that table: below the 1.5 kW and 2 kW parts, above the 350 W pair and the single ended rows.
300 MHz is the point on this table where the top of the window is no longer a small fraction of the bottom. An HF to 0.3 GHz part is asked to work from a few megahertz, where the matching network is a transformer the size of a fist, up to 300 MHz, where a quarter wavelength is 250 mm and printed lines are practical. No single network does both well, so the row describes a class and the buyer has to state the sub band.
That is not a defect of this part. It is how a wideband HF table works, and every row on it carries the same instruction implicitly. What makes the HXC50125 worth a separate page is the arithmetic at one kilowatt, which is the power level where a single pair stops being a bench amplifier and starts being a transmitter module.
The HXC50125 rows as the vendor publishes them
| Part class | LDMOS RF power transistor, push pull pair |
| Frequency range, index row | HF to 0.3 GHz |
| Top frequency in MHz, calculated | 300 MHz |
| Wavelength at the top of the window, calculated | 1.0 m in air |
| Saturated output, index row | 500 W times two |
| Pair total, calculated | 1000 W, 60.00 dBm |
| Per side, calculated | 500 W, 56.99 dBm |
| Step below the 2 kW pair, calculated | 3.01 dB |
| Step above the 350 W pair at 500 MHz, calculated | 4.56 dB |
| Drain rail, index row | 50 V |
| Load voltage at 1000 W into 50 ohm, calculated | 223.6 V rms, 316.2 V peak |
| Peak against the rail, calculated | 6.32 times |
| Load voltage per side at 500 W, calculated | 158.1 V rms, 223.6 V peak, 4.47 times the rail |
| Peak at a two to one mismatch, calculated | 632.4 V |
| DC input at 55 per cent, calculated | 1818 W, 36.4 A at 50 V, 818 W of heat |
| DC input at 65 per cent, calculated | 1538 W, 30.8 A at 50 V, 538 W of heat |
| Output per megahertz of window, calculated | 3.3 W |
| Gain | Not published |
| Drain efficiency | Not published |
| Mode, index row | CW |
| Package and flange | Not published |
| Thermal resistance, junction to case | Not published |
| Load impedance | Not published, no load pull table |
| Data sheet | None reachable for this row |
One kilowatt, six rail heights and a 36 A supply
1000 W into 50 ohm is 223.6 V rms and 316.2 V peak, so the load peak sits 6.32 times above the 50 V rail. That is the middle of the range on this table: less extreme than the 2 kW pair at 8.94 times and more extreme than the 350 W pair at 3.74 times. If a buyer is moving a build between rows, the transformer turns ratio has to move with it, and a 6.32 to 1 ratio is close enough to 6 to 1 that an existing transformer can sometimes be reused with a tap change rather than replaced.
The supply side is a 36.4 A draw at 55 per cent efficiency, falling to 30.8 A at 65 per cent. At these currents the resistance of the feed becomes visible. A 10 milliohm path from the bus to the flange drops 0.36 V at 36 A, which is 0.7 per cent of the rail and costs about 0.03 dB, small enough to ignore. A 100 milliohm path drops 3.6 V, which is 7 per cent of the rail and enough to move the operating point, so the wiring and the connector are part of the electrical budget on this part.
The heat is 818 W at 55 per cent and 538 W at 65 per cent. At 300 MHz that heat is spread over a die that is still reasonably large compared with a 2 GHz part, so the flux per square millimetre is moderate and a well coupled cold plate with a 0.2 K per watt interface is usually enough. The number that decides it is the thermal resistance of the package, which the vendor does not publish for this row.
The window: what HF to 300 MHz actually means at both ends
At the bottom of the window the transistor sees an impedance that is very low in real terms, because 1000 W into a low impedance means a large current. The output network at that end is a transformer with a ferrite core, and the core loss and saturation margin are part of the build of the amplifier rather than of the device. A buyer who intends to operate near the bottom of the window should say so, because the device is the same but the network is not.
At the top of the window, 300 MHz, the network is short enough to be built as printed lines on a board with a dielectric constant in the usual range, and the loss per unit length starts to matter. A 300 MHz stage built with a low cost laminate can lose 0.3 to 0.5 dB in the output network, which at 1 kW is 70 to 120 W of heat in the board. That loss is invisible in the device efficiency figure and it is one of the reasons a transmitter that meets its transistor numbers still runs hotter than expected.
Between the two ends, the row is a compromise. The vendor does not publish a gain against frequency curve for this part, so a buyer cannot know where the gain rolls off inside the window without measuring it. On a first article, take gain at five or six frequencies and build the drive budget from the measurement, not from a single number.
Where the HXC50125 sits and what it replaces
Below it in power are the 175 W pair and the 700 W pair, both on a 500 MHz window, and the single ended 250, 170 and 80 W rows. Above it are the 1.5 kW and 2 kW pairs. A buyer who needs 1 kW at 300 MHz has no other row on this table that covers the frequency with that power, so the HXC50125 is the default rather than a choice.
Buyers often ask whether two 500 W single ended parts would be cheaper than one pair. On this table the single ended rows stop at 250 W, so the answer requires four parts and a 4 way combiner, which is 6 dB of combining loss budget and four times the assembly work. At 1 kW the pair is almost always the cheaper route. The drive, output and rail comparison across the family is on the RF power transistor cross reference page.
What the pair does not give is redundancy. A single device failure takes the whole 1 kW stage down. A system that must stay on air needs either two stages combined or a spare module on the shelf, and both are decisions made above the transistor line.
Buying the HXC50125: what the order has to state
State the sub band inside HF to 300 MHz, the rail, the mode, the flange and body, the quantity, and the gain and efficiency the factory will guarantee. State also whether the output network and the balun come from the buyer, because on this row the answer decides the price of the module more than the price of the device does.
The incoming test should include gain at three frequencies, output at the rated drive, and a balance check between halves. Record the drive level at each point, because a part that reaches 500 W per side with 1 dB more drive has changed the stage in front of it. The record structure is set out on the incoming inspection plan page.
For a module build, the device, the balun, the output capacitors, the current sensor and the cold plate can be consolidated on one purchase against one date, which is what the one stop RF supply page covers. At this power level the cold plate and the balun are on the critical path more often than the transistor is.
Questions buyers ask about the HXC50125
Is 1 kW from one device? It is 500 W times two, so 1 kW is the pair total at 60.00 dBm. Each half is 56.99 dBm.
Can it run at 430 MHz? No. The row stops at 300 MHz. For the 500 MHz band take the 700 W pair or the 350 W pair.
What is the current draw? 36.4 A at 55 per cent efficiency and 30.8 A at 65 per cent, both calculated on a 50 V rail.
Does it need a circulator? Not stated by the vendor, but at 1 kW output and a 632 V peak under mismatch, protection is normally part of the amplifier rather than of the device.
How much gain? Not published. Measure it on the first article, since the drive budget depends on it and a 5 dB error there changes the driver chain.