MAX8969EWL42+T
Product Specifications
MAX8969EWL42+T
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The MAX8969EWL42+T from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
MAX8969EWL42+T: 1 A From One Cell and Three Different Quiescent States
The MAX8969EWL42+T is a synchronous step-up converter from Analog Devices for single-cell lithium-ion equipment. Input range is 2.5 V to 5.5 V and the published output options run 3.3 V to 5.7 V, so the converter can hold a 5 V rail up from a cell that is already at 3.0 V. Output current is up to 1 A, switching frequency is 3 MHz, and efficiency is quoted above 90 percent with the internal synchronous rectifier. The package is a 9-bump wafer level package 1.25 mm by 1.25 mm on a 0.4 mm pitch, which is the reason the part exists: at 3 MHz the inductor and the output capacitor are small enough to sit beside it. Protection covers input undervoltage lockout, short circuit and overtemperature shutdown, and the output is disconnected from the inductor in shutdown so no current flows from OUT to LX.
One amp at 5 V from 3.3 V asks the cell for 1.68 A
Five watts out at 90 percent is 5.56 W in, and at a 3.3 V input that is 1.68 A of cell current. At 3.7 V it is 1.50 A, and a 3.0 V input on a 3.3 V output is 1.22 A. The output rating is 1 A in every case; the input current is what the cell, the protection circuit and the connector see, and on a single cell it is the larger of the two numbers. A board that quotes 1 A and then puts a 1.5 A rated battery protection FET in the path has sized the protection to the output rather than to the input, and the 3 MHz switching makes the peak current higher than the average by the inductor ripple. The honest way to read the headline is that it is an output current at a stated input, and the input current is the number the rest of the system has to carry.
Three quiescent figures are three different jobs
The data sheet gives 45 microamps in step-up mode, 30 microamps in track mode and 60 microamps in automatic track mode. Track mode disables the boost circuits and lets a p-channel MOSFET pass the input to the output as a current limited switch, so the rail follows the cell down; automatic track mode keeps the boost alive and moves into boost when the input falls to 95 percent of the target output. At 3.7 V the 45 microamp figure is 167 microwatts, and a year at that current is 0.394 Ah. Track mode at 30 microamps is 0.263 Ah over a year and automatic track at 60 microamps is 0.526 Ah. In a product that sleeps for months, the difference between those three modes is a third of the energy budget, and it is set by a pin rather than by a part change.
What the 42 in the order code decides
The suffix in this family is the fixed output option, and the family table spans 3.3 V to 5.7 V. The 42 code belongs to that table rather than to the package, so two reels with different suffixes are not interchangeable on a board that has no feedback divider. Buyers who are replacing a part on an existing board should read the suffix off the old reel or off the assembly drawing rather than from a distributor description, because the package and the pinout are the same across the options and only the internal divider differs. That is also why a cross reference entry that matches on package alone is not a match.
| Parameter | Published value | What it decides |
|---|---|---|
| Input range | 2.5 V to 5.5 V | One Li+ cell, 3.0 V end of discharge included |
| Output options | 3.3 V to 5.7 V | The order code suffix picks one |
| Output current | Up to 1 A | 1.68 A of input current at 3.3 V in |
| Quiescent, step-up | 45 uA | 0.394 Ah over a year at 3.7 V |
| Quiescent, track | 30 uA | 0.263 Ah over a year |
| Quiescent, automatic track | 60 uA | 0.526 Ah over a year |
| Shutdown | 1 uA | 0.0088 Ah over a year |
| Soft start inrush limit | 480 mA | 104 us to charge 10 uF to 5 V |
| Switching frequency | 3 MHz | 333 ns period, small inductor and capacitor |
| Package | 9-bump WLP, 1.25 by 1.25 mm, 0.4 mm pitch | Board area, and a 0.4 mm stencil |
Does the 480 mA inrush limit slow a 1 A startup?
It limits the current the converter is allowed to draw while the output rises, not the current it can deliver afterwards. Charging 10 microfarads to 5 V at 480 mA takes 104 microseconds, so the ramp is short compared with the time a processor needs before it enables its own rails, and the limit is there to keep the cell voltage from collapsing under a large output capacitor. A board with 22 microfarads would take about 229 microseconds, still short, and the number that matters is whether the cell's internal resistance plus the protection FET can hold the input above the undervoltage lockout during that window. If the rail drops below the lockout during startup, the answer is a smaller output capacitor rather than a larger inductor.
Which mode keeps a stand-by module alive longest?
Track mode, because the boost is off and only the pass device and its control are biased, at 30 microamps. The cost is that the output follows the input down, so any circuit behind the rail sees a falling supply and has to tolerate it or be shut off before the cell reaches its end voltage. Automatic track mode keeps full regulation and spends 60 microamps for it, which is the right trade when the load wakes without warning. Step-up mode at 45 microamps sits between the two and does not follow the input. The choice is a system decision, and it belongs in the same table as the sleep current of the processor. Related parts across the range are indexed on the power management cross reference, the lead time side of a second source is covered on the component lead time page, and the full category is the analog and mixed-signal index.
Request Quote — In Stock, 100% New & Original, Full Warranty