Contact Us

MAX8212CPA+

Brand: Analog Devices
Analog Devices MAX8212CPA+ is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

MAX8212CPA+ — Analog & Mixed-Signal ICs | Superb Automation

MAX8212CPA+

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The MAX8212CPA+ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

MAX8212CPA+: A 5 uA Voltage Detector Whose Divider Costs as Much as the Part

The MAX8212CPA+ is a CMOS micropower voltage detector in an 8-pin plastic DIP that warns a microprocessor of a power failure. It contains a comparator, a 1.15 V bandgap reference with plus or minus 3.5 percent accuracy, which is plus or minus 40 mV, and an open-drain n-channel output driver. Two external resistors set the trip voltage against the internal reference, a separate hysteresis output allows positive feedback for noise free switching, the supply range is 2.0 V to 16.5 V, and the quiescent current is 5 uA. The MAX8211 and MAX8212 differ in output behaviour: the MAX8211 sinks a current limited 7 mA when the threshold pin falls below 1.15 V, while the MAX8212 turns its output on when the threshold pin rises above 1.15 V and has no current limit.

This is the cheapest way to add a power-fail warning to a product that already has a supervisor for its main rail. The part itself draws 5 uA, and the board decision that decides whether it stays at 5 uA is the resistor divider, not the integrated circuit.

The divider spends 4.48 uA to set a 4.5 V trip, which is 90 percent of the part

For a 4.5 V trip the divider has to put 1.15 V on the threshold pin, a ratio of 0.2556. With 750 kOhm and 255 kOhm the trip lands at 4.53 V and the divider draws 4.48 uA at 4.5 V, which is 90 percent of the 5 uA the part itself uses. The total for the function is therefore 9.5 uA, and a resistor pair chosen for a lower current would need megohms, where the threshold pin bias current and board leakage start to dominate the ratio. That trade is the real engineering in a micropower voltage detector, and it is why the divider current should be a line in the power budget rather than an afterthought.

The trip accuracy is set by the reference and the resistors together. The plus or minus 3.5 percent on the reference is 158 mV at a 4.5 V trip, so the threshold is somewhere between 4.34 V and 4.66 V before resistor tolerance is counted. That is a wide window, and it is the reason this part is used for a warning rather than for a precision cutoff: the system has to be able to act on a warning that arrives anywhere in a 320 mV band.

Quiescent current5 uA, plus 4.48 uA in a 750 kOhm and 255 kOhm divider
Reference1.15 V bandgap, plus or minus 3.5 percent, plus or minus 40 mV
Trip accuracy at 4.5 VPlus or minus 158 mV from the reference alone
Supply range2.0 V to 16.5 V, so a 12 V rail has 4.5 V of headroom
OutputOpen drain n-channel, behaviour differs between the MAX8211 and MAX8212
PolarityThis part turns on above 1.15 V, the MAX8211 sinks below it
Current limit7 mA on the MAX8211, none on the MAX8212
HysteresisSeparate hysteresis output for positive feedback
Second sourceImproved replacement for the ICL8211 and ICL8212
Package8-pin plastic DIP as CPA, also SOIC and ceramic DIP in the same family

Sixteen and a half volts is the ceiling, and a 24 V rail is outside it

The supply range stops at 16.5 V, so a 12 V industrial rail at plus 10 percent is 13.2 V and sits 3.3 V inside the limit, which is comfortable. A 24 V rail is not: the part would need a pre regulator or a divider ahead of its own supply pin, and a divider on the supply changes the very current the part was chosen for. Any product above 16.5 V therefore uses a different detector, and the family's low current is not available there.

The open-drain output is what allows the warning to be wired to a line that other sources also drive, and it is the reason the polarity difference between the two members matters. A MAX8211 in a socket built for a MAX8212 inverts the warning: the line that should go low on a power failure goes low while the supply is good. Both parts are 8-pin, both draw 5 uA, and the difference is one word in the order code.

Two questions buyers ask

Can the hysteresis output be used to drive something else?
It is intended as positive feedback into the divider, which is why it exists: it moves the trip point after the output changes state and stops the detector from oscillating on a slowly falling rail. Using it as a second output is possible but the drive capability is limited to the feedback function, and a load on that pin changes the hysteresis window itself.

Can it drive a relay or an optocoupler?
The MAX8212 output has no current limit and the MAX8211 limits at 7 mA, so a small optocoupler LED or a high impedance logic input is within reach and a relay coil is not. Where a relay has to be driven, the detector drives a transistor and the transistor drives the coil, which also keeps the relay's switching noise away from the threshold pin.

Ordering and supply

The CPA suffix is the 8-pin plastic DIP. Traps in this family are the output polarity, the current limit and the supply ceiling. A part that is pin compatible and 5 uA but inverts its output produces a warning that arrives when the supply is healthy, and a part with a 16.5 V ceiling fitted to a 24 V rail fails on the first transient. Both are order code differences, not family differences.

We hold and source this family for production and for repair lots. Start at the analog mixed signal ICs family page, compare a candidate against the power management cross reference, and where a detector has to be replaced in an existing instrument, the order in how to verify a drop in replacement puts the polarity and the divider ratio ahead of the socket check.

Request Quote — In Stock, 100% New & Original, Full Warranty