MAX811LEUS+T
Product Specifications
MAX811LEUS+T
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The MAX811LEUS+T from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
MAX811LEUS+T: 4.63 V Means a Legal 5 V Rail Can Sit Exactly at the Trip Point
The MAX811LEUS+T is the L threshold option of the MAX811 four-pin voltage monitor from Analog Devices, 4.63 V nominal, in the 4-pin SOT143 package on tape and reel. It watches a 5 V rail, holds the active-low reset output down while the rail is below the threshold and for at least 140 ms after it recovers, and adds a debounced manual reset input with a 20 kohm typical internal pull-up. The published table gives 6 uA typical and 10 uA maximum supply current, a 4.50 V to 4.75 V threshold window over -40 C to +85 C, 40 us from a rail 125 mV below threshold to the reset asserting for the L and M options, and a 10 us minimum manual reset pulse.
A zero margin against a five percent rail
The L window is 4.54 V to 4.72 V at 25 C, which is plus or minus 1.94 percent, and 4.50 V to 4.75 V over temperature. A 5 V rail at minus five percent is 4.75 V, which is exactly the upper limit of the window. There is no margin: a unit whose threshold sits at the top of the table and a rail sitting at the bottom of its tolerance meet at the same voltage, and the board resets depending on temperature and on which unit was fitted. At minus ten percent the rail is 4.50 V, which is exactly the lower limit, so the entire window is above the rail and every unit trips on a rail that is still within a common ten percent tolerance.
The M option at 4.38 V is the conventional choice for a five percent 5 V rail, because 4.50 V of window top leaves 250 mV below the 4.75 V rail floor. The L option is a 5 V rail with tight tolerance, or a rail whose low limit is above 4.85 V. Buying the L option because the rail is nominally 5 V is the mistake this table prevents.
The manual reset input on a 5 V rail
The MR logic high threshold is 0.7 times VCC, which is 3.5 V at a 5 V rail. A 3.3 V microcontroller output reaches 3.3 V at best and typically 3.2 V under load, so it never crosses 3.5 V: the monitor sees a permanent press and the board stays in reset. Drive the pin with an open-drain output to ground, or use a small N-channel device, and the 20 kohm internal pull-up brings it back up without an external resistor. The 100 ns glitch immunity and 10 us minimum pulse mean a 10 nF capacitor gives a 0.2 ms time constant that debounces a mechanical switch without making the press feel slow.
The 40 us rail to reset delay is twice the 20 us of the T, S and R options, which follows from the higher threshold and the same comparator. On a 5 V rail falling at 100 V per second, 125 mV takes 1.25 ms, so the reset arrives 40 us after the rail has already passed the trip point.
What the L option does not do
It does not protect a 5 V rail from a slow brownout that stays between 4.75 V and 4.50 V, because that band is inside the threshold window. It also does not monitor the 3.3 V rail, which needs the S or T option. And it does not replace a supervisor with a watchdog: there is no time-out on the processor, only a time-out on the rail, so a firmware hang on a healthy rail is invisible to this part.
| Parameter | Published value | What it decides |
|---|---|---|
| Threshold, L option | 4.63 V nominal | A 5 V rail part with tight tolerance |
| Window at 25 C | 4.54 V to 4.72 V | Plus or minus 1.94 percent |
| Window, -40 C to +85 C | 4.50 V to 4.75 V | Zero margin against a 5 V rail at minus five percent |
| M option for comparison | 4.38 V nominal, 4.25 V to 4.50 V | 250 mV of margin on the same rail |
| MR threshold | 0.7 x VCC high, 0.25 x VCC low | 3.5 V at 5 V, so 3.3 V logic cannot drive it |
| MR pull-up | 20 kohm typical, 10 to 30 kohm | A 10 nF capacitor gives 0.2 ms of debounce |
| Rail to reset delay | 40 us at 125 mV below threshold | Twice the delay of the lower threshold options |
| Supply current | 6 uA typical, 10 uA maximum | 20 uW at 3.3 V, 30 uW at 5 V |
Questions buyers ask before they order this part number
Will the L option work on a 5 V rail from a USB supply? USB allows 4.75 V at the far end of the cable, which is the exact top of the L window, so the answer is no without checking the threshold of the units in hand. The M option is the one that tolerates a USB rail.
Is the RESET output push-pull? Yes, on both the MAX811 and MAX812, with the MAX811 active low and the MAX812 active high, so a processor whose reset is active high needs the MAX812 number. Two push-pull outputs cannot share one net, which is the case for an open-drain MAX803 and a single pull-up instead.
The part is listed in analog and mixed-signal IC category. Supervisory chains on new boards are compared on power management cross reference, and boards being verified after a substitution start from how to verify a drop in replacement.
Request Quote — In Stock, 100% New & Original, Full Warranty