LTM8058EY#PBF
Product Specifications
LTM8058EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8058EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8058EY: the isolated plus LDO module for a 0 to 125 degree specification
The LTM8058EY#PBF is the commercial grade of the isolated flyback with post regulator: 3.1 V to 31 V in, 2.5 V to 13 V at up to 440 mA on the isolated output, 1.2 V to 12 V at up to 300 mA after the LDO, 2 kVAC barrier tested at 3 kVDC, in an 11.25 mm by 9 mm package. The E grade is guaranteed from 0 to +125 degrees internal, with the -40 degree end assured by characterisation rather than test. For isolated analogue front ends inside heated cabinets, that is the same part at a shorter qualification trail.
Published values
| Parameter | Value |
|---|---|
| Input range | 3.1 V to 31 V |
| First output | 2.5 V to 13 V at up to 440 mA |
| Post regulator output | 1.2 V to 12 V at up to 300 mA |
| Sum rule | VIN plus VOUT1 limited to 36 V |
| Isolation | 2 kVAC, tested at 3 kVDC for one second |
| Post regulator dropout | 0.25 V at 10 mA, 0.34 V at 100 mA, 0.43 V at 300 mA |
| Post regulator noise | 20 microvolts RMS over 100 Hz to 100 kHz |
| Guaranteed range | 0 to +125 degrees internal by test; -40 to +125 assured by characterisation |
| Quiescent current | 1 microamp with RUN at 0 V, 850 microamps not switching |
| Package | 11.25 mm by 9 mm by 4.92 mm BGA, 1.1 g |
| Thermal | 23.2 degrees per watt to ambient |
| Finish | SAC305 RoHS, tin lead under the same device code |
Grades in this family behave differently from the step-down modules
On the 40 V step-down modules the E grade is a genuinely narrower window: 0 to 125 degrees against -40 to 125. On this isolated family the order table lists both E and I across -40 to +125, and the note explains why: the E grade is tested from 0 degrees, and the rest of the range is assured by characterisation and statistical correlation. The distinction is about evidence, not about the window printed on the reel.
So a purchase decision here is about documentation. If the product specification claims -40 and a customer audits the test data, the I grade is the clean answer. If the product is a heated cabinet instrument that never sees below 0, the E grade carries the same operating numbers with a shorter data pack.
The LDO is the thermal decision, not the flyback
At 300 mA the post regulator dissipates the difference between VOUT1 and VOUT2, which at 5 V to 3.3 V is 0.51 W inside the same package as the flyback. That single term is larger than the flyback's own loss at this power level, and it is what makes a 300 mA load a thermal question while a 100 mA load is not.
Lowering VOUT1 towards the LDO output is the fix. At 3.8 V first output, the LDO loss at 300 mA falls to 0.15 W and the 0.43 V dropout is still respected. The cost is that the flyback now runs a step down ratio closer to the sum rule, which is where its efficiency is best anyway.
Where this part is the shortest route to a certified rail
A discrete isolated supply needs a transformer with a recognised insulation system, a controller, an opto or a third winding for feedback, and its own emissions testing. This module brings the transformer and the controller inside a part that is already recognised, which turns a two week exercise into a line on the BOM.
The qualification is still the system's: the enclosure, the creepage to the chassis and the production hipot routine are outside the module. What the module does is remove the uncertain part, the transformer and its insulation paperwork.
For a board that has to keep running while a reel runs out, medical device components is where the family alternatives sit, the power management cross reference is the check list before a substitute goes in, and component lead time solutions is how a gap is covered without a new line item.
Two questions buyers ask about the E grade
Does the E grade cover -40 degrees at all? The order table prints -40 to +125, but the guarantee note says the E grade is tested from 0 degrees and the rest of the range is assured by characterisation. If a customer asks for test evidence at -40, the I grade is the answer.