The LTM8049EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8049EY: two SEPIC rails for equipment that starts at room temperature
The LTM8049EY#PBF is the commercial grade of the dual SEPIC and inverting module: 2.6 V to 20 V in, plus or minus 2.5 V to 24 V out on two independent halves, 1 A at 5 V from a 12 V input, and a switching range of 200 kHz to 2.5 MHz. The electrical table is shared with the industrial code, including the 1.204 V feedback reference on a positive rail and the 7 mV reference on a negative one. The single line that moves is the guarantee, which starts at 0 degrees instead of -40, and for a rack unit or a bench instrument that is the whole difference.
Published values
| Parameter | Value |
|---|---|
| Input range | 2.6 V to 20 V per side |
| Output range | 2.5 V to 24 V or -2.5 V to -24 V |
| Output current | 1 A at plus or minus 5 V from 12 V in; 0.25 A at plus or minus 24 V |
| Switching frequency | 200 kHz to 2.5 MHz, one resistor per side |
| Feedback reference | 1.204 V positive output, 7 mV negative output |
| Guaranteed range | 0 to +125 degrees internal; -40 assured by characterisation |
| Quiescent current | 10 mA at no load, 2 microamps shut down |
| Line and load regulation | 0.1 percent and 0.3 percent |
| Power good | one open drain output per half, for event based sequencing |
| Thermal | 16.2 degrees per watt to ambient, 3.8 to the board |
| Package | 77 lead BGA, 15 mm by 9 mm by 2.42 mm, MSL 3, 0.8 g |
| Assembly | not recommended for second side reflow |
The zero degree line, read against a real cabinet
A 0 to 125 degree guarantee covers every rack product, every bench instrument and every mains powered box that is only ever started in a room. It does not cover the cabinet on a pole, the unit in an unheated store that is switched on in January, or the vehicle product that cranks at minus 30. The storage rating is -55 to +125, so nothing is damaged by the cold, but the regulated behaviour while cold is not what the E grade promises.
Because the order table lists both codes over the same -40 to +125 window, the part marking is identical and the grade shows only on the reel label. That is worth writing into the incoming inspection record for this family, since a mixed reel cannot be sorted by looking at the parts.
What two rails from one package actually saves
Two separate single modules at this current level take two footprints, two sets of input capacitors and two placements. The dual module takes 15 mm by 9 mm and one set of input ceramics, which on a dense analogue board is often the difference between fitting the bipolar supply and moving it to a second board. The two halves also share a clock output, so they can be locked together instead of beating against each other.
What it does not save is the output side. A SEPIC and an inverting rail each need their own output capacitor and their own divider, and the negative rail needs a divider computed against 7 mV rather than 1.204 V. The saving is in the input and the placement, not in the passives around the outputs.
Where the current falls off, and how to quote it
The headline is 1 A at 5 V from 12 V. At 24 V the same module delivers 0.25 A, and the fall is set by the conversion ratio rather than by the package: at 0.25 A and 24 V the output is 6 W, and the 16.2 degrees per watt path would allow 2.47 W of loss at an 85 degree ambient, which is a 71 percent efficiency floor the part meets comfortably. The limit is the switch current and the ripple inside the module.
So a request for plus and minus 15 V at half an amp from a 5 V bus is not this part, and the honest answer is a pair of larger inverting modules or a transformer based approach. A request for plus and minus 5 V at 1 A, or plus and minus 12 V at a few hundred milliamps, is squarely inside the curve.
Sourcing notes for this family: OEM procurement holds the cross references, the power management cross reference is the pre substitution check, and vendor consolidation is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask about the dual E grade
Is the E grade the same silicon as the I grade? Yes, same die and same package, and the order table gives both the same -40 to +125 window. The difference is that the I grade carries guaranteed limits across the whole window while the E grade is guaranteed from 0 degrees and characterised below it.
Can this module make a negative rail without a second part? Yes. Ground the positive output rail of that half and it runs as an inverting converter with the negative feedback reference, so a single module produces one positive and one negative rail.