LTM8003IY#PBF
Product Specifications
LTM8003IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8003IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8003IY#PBF: 3.5 A from 40 V, 25 uA at no load, and the 125 degree C junction behind the I grade
The LTM8003IY#PBF is a 40 V input, 3.5 A continuous and 6 A peak step-down module in a 6.25 mm by 9 mm by 3.32 mm ball grid array, built around the Silent Switcher arrangement that keeps the emissions low at switching frequencies up to 3 MHz. The output range is 0.97 V to 18 V, the quiescent current is 25 uA at a 5 V output, and the I grade is limited to a 125 degree C internal temperature where the H grade in the same family is rated to 150 degree C. The difference between those two numbers is power, not marketing: it is the loss budget a board can spend at a given ambient.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 3.4 V to 40 V, 42 V absolute maximum |
| Output voltage | 0.97 V to 18 V, 3.3 V fixed version available |
| Output current | 3.5 A continuous, 6 A peak |
| Switching frequency | 200 kHz to 3 MHz, set by one resistor |
| Frequency setting | 232 k for 200 kHz, 41.2 k for 1 MHz, 10.7 k for 3 MHz |
| Quiescent current | 25 uA at 5 V out |
| Feedback voltage | 950 mV to 980 mV, 970 mV typical |
| Power good thresholds | 1.05 V rising and 0.89 V falling at FB |
| Thermal resistance | 24.7 degree C per W |
| I grade maximum junction | 125 degree C |
| H grade maximum junction | 150 degree C |
| Emissions | CISPR25 Class 5 compliant, Silent Switcher architecture |
Duty cycle at 40 V is where the switching frequency stops being free
Forty volts in and 5 V out is a 12.5 percent duty cycle, which at 1 MHz is 125 ns of on time and at 3 MHz is 41.7 ns. The 3 MHz setting is what shrinks the inductor and the output capacitor, and it is also what makes a 40 V to 3.3 V conversion an 8.25 percent duty cycle and a 27.5 ns pulse. Below a certain pulse width the loop cannot regulate cleanly, so the top of the frequency range and the top of the input range cannot both be used with a low output.
The arithmetic for a given build is the same three numbers every time: duty cycle is output divided by input, on time is duty divided by frequency, and the resulting pulse has to be longer than the minimum on time of the part plus the rise and fall of the switch node. A 40 V to 12 V rail at 3 MHz is a 30 percent duty and 100 ns, which is comfortable; a 40 V to 1.5 V rail at the same setting is 3.75 percent and 12.5 ns, which is not.
Twenty five microamps at no load is a battery figure
At 5 V out and no load the module draws 25 uA from the input, which is 0.125 mW from a 5 V rail and 0.219 mAh over a year from a battery. That is what makes the part usable on a rail that has to stay alive while the rest of the product sleeps, and it is why the mode changes at light load rather than holding a fixed frequency. The price is burst behaviour and a slightly higher output ripple at no load, which the data sheet shows in its efficiency curves rather than in a table.
At 3.5 A and 5 V the output is 17.5 W; at 90 percent that is 19.4 W in, or 486 mA from a 40 V rail, and the 1.94 W of loss at 24.7 degree C per W is a 48 degree C rise. With an 85 degree C ambient that is 133 degree C, which is over the I grade limit and inside the H grade one. The same board with 2 A of load has 1.1 W of loss and a 27 degree C rise, which is where the I grade is comfortable. That is the calculation that decides IY or HY.
Power good, tracking and the fixed 3.3 V version
The power good comparator trips at 1.05 V rising and 0.89 V falling on the adjustable version's feedback pin, which is 8 percent high and 8 percent low around the 970 mV reference. On the fixed 3.3 V version the window is 3.57 V and 3.03 V at the output, the same plus or minus 8 percent. A sequencer that treats power good as a precise threshold is therefore reading a window, not a point, and a rail that sits at 3.2 V never asserts it.
The TR/SS pin sets the ramp with a capacitor and pulls the output down when taken to ground, so the same pin does soft start and shutdown. The LTM8003-3.3 version adds a pinout that stays at or below the regulation voltage if an adjacent pin is shorted or left floating, which is the variant an automotive or medical build wants when a single point failure has to be non hazardous.
Where a customer needs a second position on this part, the power management cross reference is the starting point, medical device components sets out the checks a substitution has to pass, and component lead time solutions is the short lead time route we quote against.
Two questions buyers ask
Is the 6 A figure a continuous rating? No. Three and a half amps is the continuous output and 6 A is the peak the switch and inductor will pass, which is a transient allowance and not a dc rating. A load that sits at 5 A continuous is outside the part even though it is inside the peak number, and the thermal arithmetic at 5 A gives more than 2.7 W of loss in a package rated 24.7 degree C per W.
What is the minimum input for a 3.3 V output? 3.4 V is the input where the part starts and the fixed 3.3 V version needs headroom above that, so a 3.3 V rail at minus five percent (3.135 V) is below the start threshold. A build that has to run from a 3.3 V backplane uses the adjustable version with a lower output or a different module in the family rather than relying on the dropout of this one.