Contact Us

LTM8003IY#PBF

Brand: Analog Devices
Analog Devices LTM8003IY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8003IY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8003IY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8003IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8003IY#PBF: 3.5 A from 40 V, 25 uA at no load, and the 125 degree C junction behind the I grade

The LTM8003IY#PBF is a 40 V input, 3.5 A continuous and 6 A peak step-down module in a 6.25 mm by 9 mm by 3.32 mm ball grid array, built around the Silent Switcher arrangement that keeps the emissions low at switching frequencies up to 3 MHz. The output range is 0.97 V to 18 V, the quiescent current is 25 uA at a 5 V output, and the I grade is limited to a 125 degree C internal temperature where the H grade in the same family is rated to 150 degree C. The difference between those two numbers is power, not marketing: it is the loss budget a board can spend at a given ambient.

Published values

ParameterValue
Input voltage3.4 V to 40 V, 42 V absolute maximum
Output voltage0.97 V to 18 V, 3.3 V fixed version available
Output current3.5 A continuous, 6 A peak
Switching frequency200 kHz to 3 MHz, set by one resistor
Frequency setting232 k for 200 kHz, 41.2 k for 1 MHz, 10.7 k for 3 MHz
Quiescent current25 uA at 5 V out
Feedback voltage950 mV to 980 mV, 970 mV typical
Power good thresholds1.05 V rising and 0.89 V falling at FB
Thermal resistance24.7 degree C per W
I grade maximum junction125 degree C
H grade maximum junction150 degree C
EmissionsCISPR25 Class 5 compliant, Silent Switcher architecture

Duty cycle at 40 V is where the switching frequency stops being free

Forty volts in and 5 V out is a 12.5 percent duty cycle, which at 1 MHz is 125 ns of on time and at 3 MHz is 41.7 ns. The 3 MHz setting is what shrinks the inductor and the output capacitor, and it is also what makes a 40 V to 3.3 V conversion an 8.25 percent duty cycle and a 27.5 ns pulse. Below a certain pulse width the loop cannot regulate cleanly, so the top of the frequency range and the top of the input range cannot both be used with a low output.

The arithmetic for a given build is the same three numbers every time: duty cycle is output divided by input, on time is duty divided by frequency, and the resulting pulse has to be longer than the minimum on time of the part plus the rise and fall of the switch node. A 40 V to 12 V rail at 3 MHz is a 30 percent duty and 100 ns, which is comfortable; a 40 V to 1.5 V rail at the same setting is 3.75 percent and 12.5 ns, which is not.

Twenty five microamps at no load is a battery figure

At 5 V out and no load the module draws 25 uA from the input, which is 0.125 mW from a 5 V rail and 0.219 mAh over a year from a battery. That is what makes the part usable on a rail that has to stay alive while the rest of the product sleeps, and it is why the mode changes at light load rather than holding a fixed frequency. The price is burst behaviour and a slightly higher output ripple at no load, which the data sheet shows in its efficiency curves rather than in a table.

At 3.5 A and 5 V the output is 17.5 W; at 90 percent that is 19.4 W in, or 486 mA from a 40 V rail, and the 1.94 W of loss at 24.7 degree C per W is a 48 degree C rise. With an 85 degree C ambient that is 133 degree C, which is over the I grade limit and inside the H grade one. The same board with 2 A of load has 1.1 W of loss and a 27 degree C rise, which is where the I grade is comfortable. That is the calculation that decides IY or HY.

Power good, tracking and the fixed 3.3 V version

The power good comparator trips at 1.05 V rising and 0.89 V falling on the adjustable version's feedback pin, which is 8 percent high and 8 percent low around the 970 mV reference. On the fixed 3.3 V version the window is 3.57 V and 3.03 V at the output, the same plus or minus 8 percent. A sequencer that treats power good as a precise threshold is therefore reading a window, not a point, and a rail that sits at 3.2 V never asserts it.

The TR/SS pin sets the ramp with a capacitor and pulls the output down when taken to ground, so the same pin does soft start and shutdown. The LTM8003-3.3 version adds a pinout that stays at or below the regulation voltage if an adjacent pin is shorted or left floating, which is the variant an automotive or medical build wants when a single point failure has to be non hazardous.

Where a customer needs a second position on this part, the power management cross reference is the starting point, medical device components sets out the checks a substitution has to pass, and component lead time solutions is the short lead time route we quote against.

Two questions buyers ask

Is the 6 A figure a continuous rating? No. Three and a half amps is the continuous output and 6 A is the peak the switch and inductor will pass, which is a transient allowance and not a dc rating. A load that sits at 5 A continuous is outside the part even though it is inside the peak number, and the thermal arithmetic at 5 A gives more than 2.7 W of loss in a package rated 24.7 degree C per W.

What is the minimum input for a 3.3 V output? 3.4 V is the input where the part starts and the fixed 3.3 V version needs headroom above that, so a 3.3 V rail at minus five percent (3.135 V) is below the start threshold. A build that has to run from a 3.3 V backplane uses the adjustable version with a lower output or a different module in the family rather than relying on the dropout of this one.