LTM8003HY#PBF
Product Specifications
LTM8003HY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8003HY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8003HY#PBF: the 25 degree C of junction the H grade adds, and what it is worth in watts
The LTM8003HY#PBF is the H grade of the 40 V, 3.5 A Silent Switcher module: the same 6.25 mm by 9 mm by 3.32 mm ball grid array as the I grade, the same 0.97 V to 18 V output range and the same 25 uA of quiescent current at 5 V out, with a maximum internal temperature of 150 degree C instead of 125. That difference is only useful if it can be converted into a loss budget, so the question a buyer should ask is how many watts of dissipation the extra 25 degree C buys at the ambient the product actually sees.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 3.4 V to 40 V, 42 V absolute maximum |
| Output voltage | 0.97 V to 18 V |
| Output current | 3.5 A continuous, 6 A peak |
| Switching frequency | 200 kHz to 3 MHz |
| Maximum junction, H grade | 150 degree C |
| Maximum junction, I grade | 125 degree C |
| Thermal resistance | 24.7 degree C per W |
| Quiescent current | 25 uA at 5 V out |
| Emissions | CISPR25 Class 5 compliant |
| Storage range, H grade | minus 50 degree C to 150 degree C |
| Package | BGA, 6.25 mm x 9 mm x 3.32 mm |
| Reflow note | not recommended for second side reflow |
Twenty five degrees is about one watt of extra loss at 85 degree C ambient
At 24.7 degree C per W, 25 degree C of junction headroom is 1.01 W of additional dissipation. In output terms at 5 V that is roughly 10 W more load if the conversion runs near 90 percent, which is nearly three times the difference between 2 A and 3.5 A of output. That is the honest way to read the suffix: at a fixed 85 degree C ambient the H part carries about 3.5 A where the I part is limited to a little over 2 A, and at 105 degree C ambient the H part is the only one of the two that can carry the full rating at all.
The arithmetic in the other direction is the reason an H grade is not automatic. It costs more, and if the board runs at 50 degree C ambient with 1.5 A of load, the loss is under 1 W, the rise is under 25 degree C, and the I grade has over 50 degree C of margin. Buying the H grade for that build spends money on a limit that is never reached.
Where the 3.5 A rating meets the 3.32 mm package
The package is 6.25 mm by 9 mm, which is 56 square millimetres of board area, and the thermal path is the ball array into the copper under it plus a small amount through the top. At 3.5 A and 5 V the output is 17.5 W, so at 90 percent there is 1.94 W to remove, most of it through the balls. The data sheet's own 24.7 degree C per W is measured on a defined test board, and a real board with two layers and thin copper is worse than that: the 24.7 figure assumes a copper area the board has to provide.
At 3 MHz the switching loss rises and the inductor ripple falls, which is why the efficiency curves show the frequency trade rather than a single number. Forced continuous operation at 3 MHz into a 1.8 V load is where the part is happiest; a 40 V to 5 V conversion at 200 kHz is where the inductor and the output capacitor are largest but the loss is lowest.
The second side reflow note and what it means for assembly
The ordering table carries a note that this product is not recommended for second side reflow, which is a statement about the module's moisture sensitivity and mass, not about its electrical ratings. A double sided assembly has to place this part on the side that is reflowed once, or use a selective process for the second pass. Getting that wrong shows up as cracked balls or an open under the module after thermal cycling rather than as a failure at first test.
The H grade also has a storage range of minus 50 degree C to 150 degree C where the I grade is narrower, and that matters for a product that is stored in an uncontrolled location before installation. Neither grade changes the 42 V absolute maximum on the input, so a 36 V rail with a load dump still needs a clamp in front of the module.
The pages that answer this most often are the power management cross reference for the family alternatives, defense grade components for the acceptance test, and component lead time solutions for the case where a replacement has to be fitted before the next build.
Two questions buyers ask
Is the H grade a different die? It is the same module with a wider guaranteed temperature range and a different test flow, and the ordering table lists it separately with its own part marking and finish code. The electrical numbers on the front page are shared, so the substitution question is whether the application needs the 150 degree C junction limit, not whether the part behaves differently at 25 degree C.
Can the module be run at 3 MHz and 40 V in at the same time? It can be clocked at 3 MHz, but the duty cycle at 40 V to 3.3 V is 8.25 percent, which is 27.5 ns of on time, and the loop needs a pulse wider than its minimum controllable width. In practice the high input and the high frequency are used with output voltages of 5 V and above, and a 1.2 V output from 40 V is run at a lower frequency so the pulse stays usable.