Contact Us

LTM8001EY#PBF

Brand: Analog Devices
Analog Devices LTM8001EY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8001EY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8001EY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8001EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8001EY#PBF: the E grade of the five rail module, and the four rails that never come from the buck

The LTM8001EY#PBF is the E grade of the 36 V module that combines a 5 A step-down regulator with five 1.1 A linear regulators in a 15 mm by 15 mm by 3.42 mm package. The E and I suffixes on this part carry the same minus 40 degree C to 125 degree C range in the ordering table, so the choice between them is about the guarantee rather than the window, and the decision that actually shapes a build is how the five linear rails are split between the buck output and the separate input.

Published values

ParameterValue
Input voltage, buck6 V to 36 V
Buck output1.2 V to 24 V at 5 A
Linear railsfive at 1.1 A, 0 V to 24 V
Rails from buck outputthree
Rails from separate inputtwo
Output noise90 uV RMS, 100 Hz to 1 MHz
Reference2 V
Current limit accuracy10 percent
Thermal resistance16.1 degree C per W
E grade rangeminus 40 degree C to 125 degree C
PackageBGA, 15 mm x 15 mm x 3.42 mm
Terminal finishSnPb or RoHS

Splitting the rails is a heat decision before it is an electrical one

With 16.1 degree C per W and a 125 degree C junction, a 60 degree C ambient leaves 4.04 W of total dissipation and a 40 degree C ambient leaves 5.3 W. Spread across five rails the 4.04 W is 0.81 W each, which at 1.1 A is a drop of under 0.74 V per regulator. Any rail with more headroom than that at full current takes more than its share, and three such rails use the whole budget before the other two are counted.

The way out is to feed the two dedicated rails from a lower input, or to run the buck output down close to the highest linear output. A 3.3 V buck feeding 2.5 V and 1.8 V rails drops 0.8 V and 1.5 V, which is 0.88 W and 1.65 W at full current, and the sum of the five rails then fits. A 5 V buck feeding the same outputs does not.

A 5 A buck behind 5.5 A of linear capacity is a deliberate mismatch

The buck is rated 5 A and the five linear rails together are 5.5 A, so a build that loads all five at 1.1 A asks the buck for more current than it can deliver, and the buck current limit becomes the system limit. In practice the rails are not all at full load at once, and the 5 A figure is the dc rating while the buck has its own peak capability, but the sum has to be checked rather than assumed: this is the one place where the module's two halves are not sized to match.

The buck also has a 10 percent accurate adjustable current limit in constant current constant voltage mode, which is used when the buck output feeds a battery or a capacitive load rather than a set of linear rails. In that mode the buck behaves as a charger and the linear array is unused, which is a legitimate configuration of the same part and a different thermal case: all the loss is in the switch, none of it in the linear pass devices.

What the E grade means on a module this size

Both the E and the I parts are listed at minus 40 degree C to 125 degree C in the ordering table, with the same 1.8 g weight and the same 15 mm body, and the difference between them is the guarantee and the test flow rather than the ambient range. A build with a 105 degree C ambient needs to look at the junction rise rather than at the suffix: at 5 W of internal loss the rise alone is 80 degree C and no suffix on this part survives that ambient.

The 15 mm square body is the other constraint. It has to sit on copper that can take the heat out of the ball array, and the data sheet's thermal number assumes a test board with a defined copper area. On a four layer board with a solid ground plane under the module the number is achievable; on a two layer board with thin copper the same 5 W gives a much higher rise and the rail budget has to come down.

Two pages worth reading before a purchase order goes out are the power management cross reference and vendor consolidation; the first lists what else fits the socket, the second is the test sequence for a drop in, and component lead time solutions covers the case where the shortage is already on the line.

Two questions buyers ask

Can the buck output be used on its own without the linear rails? Yes. The buck is a complete 5 A regulator and the linear array is a separate section of the same package, so a build that only needs the buck leaves the five outputs unconnected. The linear sections still draw their own quiescent current from their inputs, so the unused rails are tied off rather than left floating.

Does the 36 V maximum input apply to the linear rails too? The two dedicated linear inputs have their own absolute maximum of 25 V on VIN45 and BIAS45, while the buck input is rated to 40 V absolute maximum. So a 36 V rail can feed the buck but cannot feed the two separate linear inputs directly, and those two have to come from a lower rail or from the buck output.