LTM4671IY#PBF
Product Specifications
LTM4671IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4671IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4671IY#PBF: The -40 C Version of the Asymmetric Quad Module
The LTM4671IY#PBF is the I grade of the asymmetric quad module: two 12 A channels at 0.6 V to 3.3 V and two 5 A channels at 0.6 V to 5.5 V, from 3.1 V to 20 V in, plus or minus 1.5 percent total DC error, dual differential sense, burst mode and tracking, in a 9.5 mm by 16 mm by 4.72 mm BGA at 1.94 g. The I grade is guaranteed over the full -40 C to 125 C internal range. It is the same part as the E code with a wider guarantee, and the same assembly notes apply: MSL 3 and not recommended for second side reflow.
Published values
| Parameter | Value |
|---|---|
| Input range | 3.1 V to 20 V, 2.9 V after start up |
| Outputs | two channels at 12 A, 0.6 V to 3.3 V, and two at 5 A, 0.6 V to 5.5 V |
| Total DC error | plus or minus 1.5 percent, 1.482 V to 1.518 V on a 1.5 V rail at 12 A |
| Current limit | 14 A on the 12 A channels, 6 A on the 5 A channels |
| Line and load regulation | 0.001 percent per volt and 0.2 percent typical on the 12 A channels |
| Switching frequency | 600 kHz default on the 12 A channels, external sync |
| Load step | 50 mV deviation and 50 us settle on a 12 A channel at 1.5 V |
| Thermal | 12 C/W junction to ambient, 1.5 C/W junction to case bottom |
| Package | 9.5 mm x 16 mm x 4.72 mm BGA, 209 balls, 1.94 g, MSL 3 |
| Temperature | I grade guaranteed -40 C to 125 C internal |
| Assembly | not recommended for second side reflow, 245 C peak body temperature |
Four rails with a 1.5 percent window each
The tighter published window on this part is on the 12 A channels: 1.482 V to 1.518 V at 1.5 V, which is 18 mV either side, and a load regulation of 0.2 percent typical with 0.5 percent maximum. Line regulation of 0.001 percent per volt is effectively nothing across 3.1 V to 20 V. The result is a rail whose DC error is dominated by the reference and the internal resistor, not by the operating point.
That matters on a core rail where the load specification is plus or minus 2 percent: this part leaves most of the budget for the copper and the sense point. On the 5 A channels the reference window is wider, 0.592 V to 0.608 V, which is 1.3 percent of 0.6 V, so the light rails are the ones to check if a customer needs the same accuracy everywhere.
The 3.1 V input floor, and what happens below it
Three point one volts is a low input floor for a module that also accepts 20 V, and it is what makes this part usable from a 3.3 V intermediate bus with only 200 mV of headroom. Once the part has started it will run down to 2.9 V, so a bus that sags during a load step keeps the rail alive. Below 2.9 V the undervoltage lockout takes over and the rails drop in sequence.
The catch is that a 3.3 V bus cannot produce a 3.3 V output. At 3.1 V in the duty cycle for a 1.2 V rail is 39 percent, and for 0.9 V it is 29 percent, both comfortable. A 2.5 V rail from a 3.1 V bus is 81 percent duty, which is the case where the minimum off time and the switch resistance start to matter.
Thermal reality on a 209 ball package
The junction to case bottom figure of 1.5 C/W is the reason this package can dissipate watts: the balls are the path, and 1.5 C/W means 7 W lifts the junction 10.5 C above the copper. The junction to ambient figure of 12 C/W describes a board with the copper already in place, so the two numbers are not alternatives, they are the same path measured at two points.
A 34 A array at 1.5 V is 51 W of delivered power. Even at 90 percent that is 5.7 W inside the package, which is inside the 7 W ceiling but only just, and it assumes 200 LFM of air at a 60 C ambient. A sealed enclosure with no airflow is outside that, and the honest answer for that case is fewer loaded rails or a heatsink on the case top.
Grade, quotation and the assembly constraint
Two order codes exist, EY and IY, both SAC305 on the same 209 ball package. The difference is the guarantee, 0 C against -40 C, and the price. For a card that ships indoors the E code is the cheaper answer; for anything that has to cold start, the I code is the only one that covers it.
Both codes carry the same two assembly notes: MSL 3 and not recommended for second side reflow. Those are the constraints that shape a build plan, and they are worth raising before a purchase order rather than after, because a board that has to go through reflow twice needs a different sequence, not a different part number.
Where a customer needs a second position on this part, component obsolescence management is the starting point, defense grade components sets out the checks a substitution has to pass, and one stop BOM sourcing is the short lead time route we quote against.
Two questions buyers ask
Is the E code usable at -40 C? It is guaranteed from 0 C to 125 C internal and the wider range is assured by characterisation rather than tested. For a specification that names -40 C, the I code is the one that can be documented.
Can the module be placed on the second side of a board? The datasheet says it is not recommended for second side reflow, so the practical answer is no on a double sided reflow process. A selective or single sided process is a different question, and it should be confirmed with the vendor rather than assumed.