LTM4651IY#PBF
Product Specifications
LTM4651IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4651IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4651IY#PBF: a negative rail where the input plus the output cannot exceed 58 V
The LTM4651IY#PBF is a 58 V, 24 W inverting module that produces a negative output from a positive input, in a 15 mm by 9 mm by 5.01 mm ball grid array. It regulates from minus 0.5 V to minus 26.5 V at up to 4 A, meets EN55022 Class B radiated emissions, and holds plus or minus 1.67 percent of total dc error from minus 40 degree C to 125 degree C. Its one hard rule is the safe operating area: the input voltage plus the magnitude of the output voltage cannot exceed 58 V, and that single line rules out most of the configurations a buyer first thinks of.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 3.6 V to 58 V |
| Output voltage | minus 0.5 V to minus 26.5 V |
| Safe operating area | input plus the magnitude of the output, 58 V maximum |
| Output current | up to 4 A, falling with output magnitude |
| Output power | 24 W from 12 V in to minus 24 V out |
| Switching frequency | 250 kHz to 3 MHz, 400 kHz default |
| DC output error | plus or minus 1.67 percent over line, load and temperature |
| Radiated emissions | EN55022 Class B compliant |
| Thermal resistance | 20.8 degree C per W |
| Package | BGA, 15 mm x 9 mm x 5.01 mm |
| Weight | 1.8 g |
| Pin referencing | RUN, PGOOD and CLKIN are referenced to ground |
Twelve volts to minus 24 V is 36 V of switch stress and 5 W of loss
The vendor's 24 W figure comes with its conditions printed: 12 V in, minus 24 V out, 5 W of loss, 60 degree C ambient, a 60 degree C rise and 200 linear feet per minute of airflow. Twenty four watts out with 5 W of loss is 82.8 percent, and 5 W at 20.8 degree C per W is a 104 degree C rise, which is why the airflow is in the condition rather than in a footnote. Without the airflow the same build is at 164 degree C and outside the part.
The 4 A rating is at the low end of the output range. At minus 24 V the output is limited to about 1 A by the 24 W figure, and the output current capability curve in the data sheet falls as the output magnitude rises. A buyer who sizes the load from the 4 A headline and then asks for minus 24 V is outside the part twice: by power and by the safe operating area.
The 58 V rule is what decides whether a 48 V telecom rail can be used
Input plus output magnitude is capped at 58 V. A 48 V telecom rail leaves 10 V for the negative output, so minus 12 V is outside the part and minus 10 V is at the limit with no margin for a tolerance. A 24 V rail leaves 34 V, which covers the whole minus 26.5 V range. That is the first question to ask of any inverting application, and it is asked before efficiency or current.
The same rule at the low end is generous: a 3.6 V input can produce minus 26.5 V because 3.6 plus 26.5 is 30.1 V, well inside 58. A battery rail inverting to a high negative voltage is therefore a natural fit for this part, while a telecom rail is not, which is the opposite of what the 58 V headline suggests to most readers.
No level shift circuitry, because the control pins sit at ground
An inverting regulator usually needs the feedback and the enable to be referenced to the negative output, which costs an op amp and a divider. On this module the RUN, PGOOD and CLKIN pins are referenced to ground, so the part connects to ordinary 3.3 V logic without any translation. That is the feature that makes it usable in a system where the negative rail is one of several and the sequencer is a standard part.
The 400 kHz default switching frequency and the 250 kHz to 3 MHz range are set by a resistor on the fSET pin, and the module can be synchronized to an external clock. A build with several rails that must not beat against each other uses one clock, and the inverting module follows it like any other converter.
Where a customer needs a second position on this part, the power management cross reference is the starting point, defense grade components sets out the checks a substitution has to pass, and component lead time solutions is the short lead time route we quote against.
Two questions buyers ask
Can it make minus 28 V from a 30 V input? No. Thirty volts in plus 28 V out is 58 V exactly, which is the boundary of the safe operating area with no allowance for input tolerance, and a 30 V rail at plus five percent is 31.5 V. The part needs the sum to stay below 58 V under all conditions, so minus 24 V from a 30 V input is the practical limit.
Is the 4 A output rating available at every output voltage? No. Four amps is the top of the current range at the low end of the output range, and the limit falls as the output magnitude rises because the 24 W power figure arrives first. At minus 24 V the output is about 1 A, and the data sheet's output current capability curve is the place to read the number for a specific voltage.
Duty cycle in an inverting regulator is not output over input
In an inverting topology the switch duty cycle is the output magnitude divided by the sum of the output magnitude and the input voltage, not output over input. At 12 V in and minus 24 V out that is 24 divided by 36, or 66.7 percent, which at the 400 kHz default is 1.67 microseconds of on time. At 250 kHz the same duty cycle is 2.67 microseconds, and at 3 MHz it is 222 ns.
That is why the part stays efficient at high step down ratios in a way a buck would not: a 12 V to minus 24 V conversion runs at two thirds duty rather than at 200 percent of an impossible number, and the switch stands off 36 V rather than 24. The 58 V safe operating area is the same statement from the other direction, since it is the total voltage the switch sees during the off time.