Contact Us

LTM4650IY#PBF

Brand: Analog Devices
Analog Devices LTM4650IY#PBF is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4650IY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4650IY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4650IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM4650IY#PBF: A Core Rail at 25 A per Channel, Priced by the Guarantee

The LTM4650IY#PBF is the I grade of the base LTM4650: two channels of 25 A, or one of 50 A, from 4.5 V to 15 V in, 0.6 V to 1.8 V out, plus or minus 1.5 percent total DC error, 35 A typical current limit per channel, differential remote sense and multiphase sharing to 300 A. The package is a 16 mm by 16 mm by 5.01 mm BGA with SAC305 balls, 3.2 g, MSL 3. The I grade is guaranteed over -40 C to 125 C internal, which is the whole rated range, so this is the code to quote when the rail has to start outdoors.

Published values

ParameterValue
Input range4.5 V to 15 V
Output range0.6 V to 1.8 V per channel
Output current25 A per channel, 50 A single output
Total DC errorplus or minus 1.5 percent at 1.2 V, 1.182 V to 1.218 V
Reference0.600 V typical, 0.594 V to 0.606 V over temperature
Current limit35 A typical per channel
Bias current240 mA continuous, 25 mA pulse skip, 4.5 mA burst, 35 uA shutdown
Switching frequency500 kHz nominal, 400 kHz to 780 kHz operating
Sync capture400 kHz to 780 kHz
Load step30 mV deviation, 20 us settle
Thermal7 C/W junction to ambient, 1.5 C/W junction to case bottom
Package16 mm x 16 mm x 5.01 mm BGA, 144 balls, 3.2 g, MSL 3
TemperatureI grade guaranteed -40 C to 125 C internal

A 1.2 V core rail, worked through

At 12 V in the duty is 10 percent, at 500 kHz the on time is 200 ns, and the 15 mV of published ripple is 1.25 percent of the rail. The 1.5 percent window is 36 mV at 1.2 V, which is the number that gets shared with the processor specification, the sense point and the copper between them. A customer who measures 40 mV of total variation at the load usually has 10 mV of it in the sense connection rather than in the module.

Load regulation is 0.5 percent typical, 0.75 percent maximum, which at 1.2 V is 9 mV from no load to 25 A. Line regulation is 0.01 percent per volt, so the 10.5 V span from 4.5 V to 15 V adds about 0.1 percent. Both are inside the 1.5 percent window with room left for the reference tolerance, which is why the total error figure is quoted as one number rather than assembled from the parts.

The bias current is the figure that sizes the standby budget

240 mA at 12 V is 2.88 W with both channels switching continuously. That is 9.6 percent of a 30 W channel, so on a rail that spends its life at low current the mode setting changes the answer more than the efficiency curve does. Burst mode drops it to 4.5 mA, 54 mW, at the cost of more output ripple at light load. Pulse skip sits between the two at 25 mA.

The module also exposes a temperature diode, a PNP with a -2.2 mV per C coefficient running at 100 uA. On a card that has no other way to see the junction, that pin plus a cheap comparator is a thermal trip that costs almost nothing, and it measures the module rather than the air around it.

Multiphase, and what 300 A really means

Six modules in multiphase reach 300 A, with the phases staggered through PHASMD and the current sharing handled inside the parts. The constraint is not the modules, it is the board: 300 A through the output copper, and a sense point that has to be moved to the load so the amplifier does not regulate the bus bar. At that current the difference between a sense trace on the load and a sense trace 10 mm away is millivolts that matter.

At more modest scale, two modules give 100 A, and that is the configuration where the phase angle between channels decides the input ripple. Setting the two modules 180 degrees apart halves the input capacitor current at the switching frequency, which is usually worth more than the extra parts.

Ordering, grade and finish

The code is family, grade I, package Y (BGA), RoHS #PBF with SAC305 balls. The E grade of the same package is cheaper with a 0 C guarantee, the MP grade is dearer with a -55 C guarantee, and the SnPb finish drops the #PBF suffix. Every one of those variants is the same converter, and the difference is what a qualification document can claim.

For a customer moving a rail from an older discrete solution, the useful comparison is not the module against a controller plus FETs on cost, it is the module against the board area, the four to six weeks of loop tuning and the passive count. A 25 A rail built from discretes usually needs 15 to 25 passives around the controller; this part needs a handful of ceramics, two set resistors and a soft start capacitor.

The pages that answer this most often are BOM shortage recovery for the family alternatives, component lead time solutions for the acceptance test, and how to reduce component cost for the case where a replacement has to be fitted before the next build.

Two questions buyers ask

Can the module be run at 1.8 V and 50 A continuously? 1.8 V at 50 A is 90 W, which at 90 percent is 10 W of loss and a 70 C rise at 7 C/W. That is beyond what the package does in still air; the published derating curves show where each input and output combination lands. A single 50 A output is realistic at the low end of the output range.

Why is the total error 1.5 percent when the reference is 0.5 percent? Because the total figure includes the internal feedback resistor tolerance, line regulation over the whole input range and load regulation from no load to 25 A. The reference on its own is 0.594 V to 0.606 V, which is 1 percent, and the rest of the budget goes on the resistor and the regulation.