Contact Us

LTM4644IY#PBF

Brand: Analog Devices
Analog Devices LTM4644IY#PBF is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4644IY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4644IY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4644IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM4644IY#PBF: A 16 A Point of Load Array and the Numbers That Set Its Board Area

The LTM4644IY#PBF is the I grade of the quad 4 A module: four channels of 4 A, 5 A peak, 4 V to 14 V in, 0.6 V to 5.5 V out, 16 A as a paralleled array, plus or minus 1.5 percent total DC error, in a 9 mm by 15 mm by 5.01 mm BGA at 1.9 g. The I grade is guaranteed over -40 C to 125 C internal. Around the module a board needs a handful of ceramics, four bottom set resistors, four soft start capacitors and nothing else, because the top feedback resistor is inside at 60.4 k and 0.5 percent.

Published values

ParameterValue
Input range4 V to 14 V, 2.375 V to 14 V with an external bias
Output range0.6 V to 5.5 V per channel
Output current4 A continuous, 5 A peak per channel, 16 A as an array
Total DC errorplus or minus 1.5 percent, 1.477 V to 1.523 V at 1.5 V
Feedback reference0.600 V typical, 0.592 V to 0.608 V over -40 C to 125 C
Current limit6 A minimum, 7 A typical per channel
Switching frequency1 MHz default, external sync
Minimum on and off time40 ns on, 70 ns off
Load step160 mV deviation, 40 us settle
Thermal10 C/W junction to ambient, 2.75 C/W junction to case top
Package9 mm x 15 mm x 5.01 mm BGA, 77 balls, 1.9 g, MSL 3
TemperatureI grade guaranteed -40 C to 125 C internal

The 40 ns on time and the 5.5 V top of the range

At 1 MHz the period is 1 us, so 40 ns of minimum on time is 4 percent duty. A 0.6 V rail from a 14 V input is 4.3 percent, which is 43 ns, just above the limit. A 5.5 V rail from 14 V is 39 percent, far away from it. The part is therefore comfortable at the top of its output range and tight at the bottom, which is the opposite of what most people expect from a wide range module.

For a 0.6 V rail the practical answer is to drop the frequency below 1 MHz or to run from a lower intermediate bus. Neither is a compromise on the module, they are what the minimum on time requires, and the same arithmetic applies to any of the four channels because they share the architecture.

Accuracy budget on a 1.5 V rail

The published window at 1.5 V is 1.477 V to 1.523 V, 23 mV either side, and the reference alone spans 0.592 V to 0.608 V over temperature, which is 1.3 percent of 0.6 V. The remainder of the 1.5 percent is the internal resistor tolerance and the regulation: 0.04 percent per volt of line and 0.5 percent of load, typical, with 1 percent as the load regulation maximum.

For a load that needs 1 percent total, this part is not the answer without a trim. For a load that accepts 2 to 3 percent, the module includes everything and the customer's own error budget only has to cover the sense point and the copper. That distinction decides more boards than the current rating.

Where the heat goes

The junction to case top figure is 2.75 C/W, the junction to case bottom 11 C/W and the junction to ambient 10 C/W. The top path is the good one, which is the opposite of a large module, and it means a thermal pad or a heatsink on top of this package is worth more than extra copper underneath. For a quad array at 16 A and 1.2 V, 19.2 W at 80 percent is 4.8 W, which on the top path is 13 C of rise.

The 5.5 W dissipation figure at a 60 C ambient with 200 LFM is the published ceiling, and it assumes airflow. In a sealed box at 70 C with no airflow the same 4.8 W is outside that envelope, and the derating curves are the place to check what the real ceiling is rather than the headline number.

Sourcing a quad module against four single modules

Four 4 A single modules take four times the board area and four times the placement, and they do not share phases unless they are synchronized. One quad module with a 16 A array takes 135 square mm and does the phase interleaving internally. The trade is that a failure takes out all four rails rather than one, and that a single channel cannot be swapped for a different current rating.

The LTM4644-1 codes exist for boards that need a PMBus controller to trim each rail. If a customer's specification calls for margining, the -1 has to be chosen before the board is laid out, because the external top resistor changes the feedback network on every channel.

Sourcing notes for this family: how to verify a drop in replacement holds the cross references, vendor consolidation is the pre substitution check, and component obsolescence management is what we use when the part on the drawing is not on the shelf.

Two questions buyers ask

Can one channel be left unconnected? Each channel has its own RUN pin, so unused channels are shut down individually and draw only their shutdown current. The inputs and outputs of an unused channel are still connected to the same rails, so the input capacitor for that channel is still worth fitting.

Is the -1 code a drop in replacement for this one? Not on an existing board. The -1 moves the top feedback resistor outside, so the feedback network per channel changes. On a new board the two are interchangeable in function; on an existing one they are not.