LTM4643MPV#PBF
Product Specifications
LTM4643MPV#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4643MPV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4643MPV#PBF: The -55 C Grade of the Ultrathin Quad 3 A Module
The LTM4643MPV#PBF is the MP grade of the quad 3 A module in the 1.82 mm LGA: 4 V to 20 V in, 0.6 V to 3.3 V out, 3 A per channel, 12 A as an array, plus or minus 1.5 percent total DC error, 0.70 g, MSL 3. The MP grade is tested and guaranteed over -55 C to 125 C internal, 15 C further down than the I grade and 55 C further than the E. On an ultrathin module that guarantee is the whole reason to select this code, because the electrical behaviour and the package are identical to the E and I parts next to it.
Published values
| Parameter | Value |
|---|---|
| Input range | 4 V to 20 V, 2.375 V to 20 V with an external bias |
| Output range | 0.6 V to 3.3 V per channel |
| Output current | 3 A per channel, 12 A as an array |
| Total DC error | plus or minus 1.5 percent, 1.477 V to 1.523 V at 1.5 V |
| Current limit | 3.5 A minimum, 5 A typical per channel |
| Bias current | 6 mA switching, 11 uA shutdown |
| Switching frequency | 1.2 MHz default, external sync |
| Thermal | 10 C/W junction to ambient, 2.75 C/W junction to case bottom, 17 C/W junction to case top |
| Package | 9 mm x 15 mm x 1.82 mm LGA, 77 lands, Au finish e4, 0.70 g, MSL 3 |
| Reflow | 260 C peak package body temperature |
| Temperature | MP grade tested and guaranteed -55 C to 125 C internal |
| Absolute maximum | 22 V on the input pins, output to input or 6 V, 125 C junction |
What -55 C means for the parts around the module
A cold start at -55 C is a test of the whole rail, not of the module. The module is guaranteed, the capacitors are not: a ceramic bank can lose more than half of its capacitance and its ESR can rise by a factor of several, so the load step deviation grows well past the 160 mV published at 25 C. The failure that shows up in a chamber is usually a rail that starts cleanly and then trips on the first load step because the bank is not there.
The second cold start issue is sequencing. The tracking pin sets the ramp and the module follows it, but if a second rail is sequenced from this one through a resistor divider, the divider's tolerance at the cold end decides whether the second rail comes up early or late. Four channels on one package make that easier to control, because all four ramps are driven from the same die temperature.
Power and heat on a 1.82 mm package
Four channels at 1.5 V and 3 A is 18 W. At 83 percent, which is what the published 0.45 A input current at 12 V works out to per channel, the loss is about 3.1 W in the package, and on the 2.75 C/W junction to case bottom path that is an 8.5 C rise over the copper under the lands. The top of the package is 17 C/W, so the same loss through the top would be 53 C. On a thin module the board is the heatsink, and a four layer board with a ground plane under the lands is worth more than any airflow.
The 5 W of dissipation the datasheet allows at a 60 C ambient with 200 LFM is the ceiling for the family, and the derating curves show how it falls with ambient. A sealed enclosure at 70 C with no airflow is outside that envelope, and the honest answer for that case is a taller package with a thermal path out of the top, not a thinner one.
The 3.5 A limit and a 3 A rating
Seventeen percent of headroom between the rating and the guaranteed minimum limit is the tightest in this family, and it shows up in two situations. A channel that has to ride through a 3 A step from a load that switches fast will come close to the limit while the loop responds. A genuine fault pulls the typical 5 A until the protection acts, which is 67 percent above the rating.
For a load that is characterised and quiet, that is fine. For a rail feeding an FPGA bank that can inrush, the limit is the number to check against the inrush, not the 3 A rating. The same arithmetic applies across the four channels because they share the architecture, and it is worth doing once for the whole array.
Order code and the quotation
MP grade, V is the LGA with Au lands, #PBF is RoHS. The BGA MP code would be MPY at 2.42 mm and 0.83 g with SAC305 balls, and the SnPb variants drop the #PBF suffix. For a customer whose specification names the MP grade, the code has to be quoted exactly, because the E and I parts are visually identical and the grade is only on the label and the paperwork.
The MP volume is the smallest of the three grades, so lead time is the risk rather than unit price. A second position on the I grade, priced and dated separately, is the standard way to keep a build on schedule when the MP code goes on allocation.
Where a customer needs a second position on this part, defense grade components is the starting point, vendor consolidation sets out the checks a substitution has to pass, and one stop BOM sourcing is the short lead time route we quote against.
Two questions buyers ask
Does the MP grade change anything about the package or the pins? No. All grades of the LTM4643 share the 77 land package and the same pin functions; the MP part differs in the guarantee and the test, which is why the order code is the only place the grade appears.
What is the output current at -55 C? The 3 A per channel rating is a DC current rating and the derating curves cover the ambient. At the cold end the limit is usually the load and the capacitors rather than the module, and the current limit stays at 3.5 A minimum across the guaranteed range.