Contact Us

LTM4627EV#PBF

Brand: Analog Devices
Analog Devices LTM4627EV#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4627EV#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4627EV#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4627EV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTM4627EV#PBF: the 15 A module in the BGA body, E grade

What this order code is

LTM4627EV#PBF is the 15 A step-down power module from the LTM4627 family in the ball grid array body, E temperature grade, RoHS finish. The package contains the switching controller, the power FETs, the inductor and the compensation network, so the parts left outside are the input capacitors, the output capacitors and one resistor that sets the output between 0.6 V and 5 V.

The letter after the family name is doing two jobs. V is the BGA body at 15 mm by 15 mm by 4.92 mm, and E is the temperature grade. The same silicon in the land grid array body is the Y code at 4.32 mm, which is 0.6 mm thinner and has pads instead of balls. Both bodies are pin and function compatible, and both are 15 mm square, so a board can take either one only while the paste and the reflow profile are treated as two separate processes.

Parameters as published

ItemValue
Output current15 A continuous
Input voltage range4.5 V to 20 V
Output voltage range0.6 V to 5 V, one external resistor
Total DC output errorplus or minus 1.5 percent
Efficiencyup to 93 percent at 12 V in, 3.3 V out
Controlcurrent mode, fast transient response
Remote sensedifferential amplifier
Parallel operationup to four modules, 60 A total
Frequencysynchronisation to an external clock, multiphase
Light loadselectable pulse skipping or burst mode
Sequencingsoft start and output voltage tracking
Protectionovercurrent foldback, output overvoltage
Body15 mm by 15 mm by 4.92 mm BGA
FinishRoHS

Numbers that decide the application

At 3.3 V and 15 A the output is 49.5 W. The published 93 percent for that exact operating point puts the input at 53.2 W, which is 4.44 A from a 12 V rail, and leaves 3.73 W to be removed. Those 3.73 W leave through 2.25 square centimetres of body, so the loss density is 1.66 W per square centimetre against 22 W per square centimetre of delivered power. The duty cycle is 27.5 percent, which is a comfortable number for a current mode stage and leaves room for the input to fall to its 4.5 V floor.

Remote sense is not a feature on a list here, it is a number. Fifteen amps through one milliohm of trace, connector and via is 15 mV, which is 0.45 percent of a 3.3 V rail and nearly a third of the total error budget the part is specified to. A board that leaves the sense pins at the module output and measures at the load has already spent that third before the module is asked to regulate anything.

Transient behaviour is arithmetic as well. A 15 A step held for one microsecond discharges 100 uF by 150 mV, and the same step held for ten microseconds discharges it by 1.5 V. The second number is why the module is bought for its loop rather than its capacitors: the loop has to take over inside the first few microseconds, and the bulk capacitors cover the rest.

Where it fits and where it does not

It fits a 12 V to 3.3 V intermediate rail on a line card, a 5 V rail at the same current, a core rail at 1 V where the current is high and the voltage is low, and any point of load where 60 A has to come from four identical bodies. It does not fit a 12 V output, because 5 V is the ceiling, and it does not fit a 24 V bus at the top of tolerance, because 20 V is the input ceiling and an unregulated 24 V adapter is already past it.

The BGA body is the taller of the two at 4.92 mm and the one with a measured standoff, so it is the easier of the two to clean under, and it is the one that allows an X-ray check of every joint. The cost is that paste volume and ball collapse have to be controlled as a process rather than inspected as a fillet.

Supply and second source questions

The family has two body letters and more than one grade, and stock is usually quoted by order code rather than by family, so a cross reference exercise has to start from the code on the line. The regulators and their protection differences are compared on the power management cross reference page.

Sourcing notes and next step

We quote the EV code as written, with the BGA body and the E grade called out, and we will say so when the only stock is the thinner Y body, because that is a process change for the assembly line and not a substitution. Send the line items and required date through the BOM shortage recovery page and we will answer with availability and alternatives. The wider power module range sits on the analog and mixed signal IC page.

LTM4627EV#PBF: four modules for 60 A is a sharing question, and a 15 A step into 500 microfarads is 450 mV

The module is a complete regulator with its own inductor and its own control loop, so paralleling is not the same exercise as paralleling a controller. Four modules share 60 A through a current share bus, and the error between them, the output capacitance and the height of the body are the three things a board built around this part has to settle. This block works the sharing error, the load step and the joint that carries the current.

One point five percent of 3.3 V is 49.5 mV, and that is the sharing error budget

The total DC output error of plus or minus 1.5 percent is 49.5 mV on a 3.3 V rail, and in a parallel arrangement that tolerance is what sets how far one module can sit from another before the share bus has to correct it. Four modules at 60 A total share 15 A each when the loop is balanced, and a 10 percent imbalance at full load is 6 A more in one module, which is a thermal question before it is an accuracy one. That is why the share bus has to be a real connection between the modules rather than a nominal one, and why the modules are placed so that the share traces are the same length.

Fifteen amps of load step into 500 microfarads is 450 mV

A 15 A step with a 1 A per microsecond slew takes 15 microseconds, and during that time the output capacitance supplies the difference. At 500 microfarads the droop is 450 mV, which is 13.6 percent of a 3.3 V rail, so the loop has to respond well before the capacitor is exhausted. The module's fast transient response is what makes the difference: a loop that recovers in 5 microseconds leaves the capacitor with 15 percent of the droop, and the capacitance value in the bill can then be chosen for ripple rather than for the step.

4.92 mm of height and a ball grid that carries 15 A

The body is 15 by 15 by 4.92 mm, and at 15 A the output current leaves through a set of balls whose combined resistance has to stay below a milliohm to keep the drop inside the error budget. Fifteen amps through one milliohm is 15 mV, which is 0.45 percent of the rail and a third of the total error. That is the same argument as remote sense, seen from the package side: a board that measures at the module output instead of at the load loses that third of the budget in the copper between them, and the sense lines have to be routed as a pair to the point of load.

Modules in parallelTotal currentPer moduleShare error at 1.5 percent
115 A15 A49.5 mV on the rail
230 A15 A49.5 mV, 3 A of imbalance at 10 percent
460 A15 A49.5 mV, 6 A at 10 percent

The module family and its current ratings are compared on power management cross reference, the checks before a second module type is paralleled into a qualified rail are on how to verify a drop in replacement, and the capacitors and connectors around it are quoted through one stop BOM sourcing.

Request Quote — In Stock, 100% New & Original, Full Warranty