LTC4364IDE-2#TRPBF
Product Specifications
LTC4364IDE-2#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC4364IDE-2#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC4364IDE-2#TRPBF: A Surge Stopper That Holds the Output Up While the Input Falls
The LTC4364IDE-2#TRPBF is a surge stopper with an integrated ideal diode controller, operating over 4 V to 80 V, withstanding surges above 80 V when the supply is clamped, an adjustable output clamp voltage, an ideal diode function that holds the output up during input brownouts, reverse input protection to minus 40 V, reverse output protection to minus 20 V, overcurrent protection, a 10 uA shutdown current at 12 V, an adjustable fault timer, and a retry duty cycle of 0.1 percent during faults on this -2 option. It is available in a 4 mm by 3 mm 14-lead DFN, a 16-lead MSOP and a 16-lead SO, is AEC-Q100 qualified for automotive applications, and is recommended for new designs.
A surge stopper is not a TVS diode and not a fuse. It sits in series with the supply, passes the current the load needs, and when the input rises above a set level it holds its output at that level by dropping the excess across an external MOSFET. The load therefore never sees the surge, which is the difference between protecting a regulator downstream and hoping the regulator survives.
Holding the output at 27 V while the input goes to 80 V is 53 V across one FET
The clamp voltage is set by a divider, and the excess appears across the pass MOSFET. A 12 V load protected at 27 V during an 80 V surge has 53 V across the FET and the load current through it, so a 2 A load means 106 W for the duration of the surge. That number sets the FET, the copper and the fault timer: the timer has to be short enough that the FET's transient thermal impedance survives, and long enough to ride through the specified surge. This is the calculation that decides whether a surge stopper is a two component or a six component answer, and it is the reason the fault timer is adjustable rather than fixed.
The ideal diode function is the second half of the part and does a different job. When the input browns out below the output, the controller holds the output up by keeping the FET on rather than allowing reverse current, so a downstream converter rides through a brief input dip without resetting. That behaviour is what a diode would do, but with 10 mOhm instead of 0.5 V of drop, and it is why this part is used in automotive and industrial supplies where the input is expected to dip rather than to disappear.
| Function | Surge stopper with ideal diode controller in one part |
| Operating range | 4 V to 80 V, surges above 80 V with the supply clamped |
| Output clamp | Adjustable, so the load never sees the surge |
| Example clamp | 27 V output from an 80 V surge leaves 53 V across the pass FET |
| Fault timer | Adjustable, sized to the FET transient thermal impedance |
| Retry | 0.1 percent duty on this -2 option, 1 ms on per second of timer |
| Reverse protection | Input to minus 40 V, output to minus 20 V |
| Shutdown current | 10 uA at 12 V, 120 uW, 88 mAh over a year |
| Qualification | AEC-Q100 for automotive applications |
| Packages | 14-lead 4 mm by 3 mm DFN as IDE, 16-lead MSOP and SO in the family |
The -2 retry option is a thermal decision made in the order code
During a persistent fault the -1 option latches off and the -2 option retries at a 0.1 percent duty cycle, which with a one second timer is one millisecond of conduction per second. Retrying means the load comes back by itself when the fault clears, which matters for equipment in an inaccessible location, and it also means the pass FET is stressed once per second for as long as the fault lasts. The average dissipation in that case is 0.1 percent of the fault dissipation, so a 106 W surge event becomes 106 mW of average heat, and the FET survives indefinitely. Latching off has no stress but needs a person or a controller to reset it.
The 10 uA shutdown current is what allows the protection to sit in front of a product that is otherwise off. At 12 V it is 120 uW, and over a year it is 88 mAh, which is a real number in a battery product and negligible in a mains one. A protection stage that draws a milliamp defeats the purpose of a low power product, which is why the shutdown current is specified at the top of a part like this.
Two questions buyers ask
Does it replace a TVS diode?
No, it complements one. A TVS clamps a transient by conducting it to ground and is the right answer for a short, high energy event; the surge stopper holds the output at a safe level for a longer event by dropping the excess in series. Where an input can see both, the TVS handles the leading edge and the stopper handles the sustained overvoltage.
What sets the maximum input voltage?
The 80 V operating range and the external FET's ratings together. The controller can withstand more with a clamped supply, but the FET sees the difference between the input and the clamped output, so the FET's drain source rating and its safe operating area decide the real limit rather than the controller's own figure.
Ordering and supply
The IDE suffix is the 14-lead 4 mm by 3 mm DFN and the -2 suffix is the 0.1 percent retry option rather than the latching one. Traps are the retry behaviour, the clamp voltage setting and the FET choice: a -1 part in a socket specified for -2 latches off after the first fault and the equipment stays down, and a clamp set too high puts the excess across the load instead of the FET.
We hold and source this family for production and for repair lots. Start at the analog mixed signal ICs family page, compare a candidate against the power management cross reference, and where a protection stage has to be replaced on a built board, the order in how to verify a drop in replacement puts the retry option and the clamp setting first.
Request Quote — In Stock, 100% New & Original, Full Warranty