LTC3765EMSE#TRPBF
Product Specifications
LTC3765EMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC3765EMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC3765EMSE#TRPBF: The Start-Up Half of a Secondary Side Controlled Forward Converter
The LTC3765EMSE#TRPBF is a start-up controller and gate driver for a self-starting secondary side controlled forward converter. Paired with the LTC3766 secondary side synchronous forward controller it forms a complete isolated supply from a small number of discrete parts. Gate drive signals and bias power are multiplexed across the isolation barrier through a small pulse transformer, and an on-chip bridge rectifier extracts the gate drive bias from that transformer, so no separate bias supply is needed. The part includes an active clamp output for driving an external PMOS with an adjustable delay, a Direct Flux Limit function that guarantees the transformer cannot saturate, a precision undervoltage lockout with adjustable hysteresis, overcurrent and overtemperature protection, an adjustable start-up frequency and soft start, and it runs from 8 V and up with the top limited only by the external components. The package is a 16-lead MSOP, and the vendor lists it as recommended for new designs.
Isolated supplies are usually built with the controller on the primary side, which means an optocoupler for the feedback and a separate bias winding for the gate drive. This pair moves the control to the secondary side, where the output voltage is measured directly, and uses the pulse transformer for both the drive signals and the bias, which removes the optocoupler and the bias winding at once.
Why the active clamp is worth the extra PMOS
In a forward converter the main switch sees the input voltage plus the reset voltage of the transformer. A clamped reset holds that at a defined level instead of letting it ring to twice the input, so the switch can be a lower voltage device with lower on resistance, and the energy stored in the leakage inductance is recovered instead of dissipated. The LTC3765 drives the clamp PMOS with an adjustable delay, and that delay is the knob that trades circulation loss against voltage stress.
The Direct Flux Limit function is the safety net. A forward converter saturates if the volt seconds applied in one direction are not balanced by the reset, and saturation takes the primary current to a destructive level in a few cycles. The part limits the flux directly rather than relying on a current sense alone, which is what lets it claim no saturation without giving up transient response.
8 V and up, with the ceiling set by the components around it
The input supply floor of 8 V is the only fixed limit; above it the maximum voltage is whatever the external MOSFETs, the transformer and the clamp can take. That is a different way of specifying a controller, and it means the same part serves a 24 V industrial input, a 48 V telecom input and a 400 V offline front end, with a different set of power components in each case.
The on-chip bridge rectifier is the detail that removes the most parts. Without it the gate drive bias for the primary side devices has to come from an auxiliary winding, a bias regulator and a start-up resistor chain, each of which is a line on the bill and a failure mode. Here it comes from the pulse transformer that is already carrying the drive signals.
| Function | Start-up controller and gate driver for a secondary side controlled forward converter |
| Pairing | LTC3766 secondary side synchronous forward controller |
| Isolation | Gate drive and bias multiplexed over a small pulse transformer |
| Bias | On-chip bridge rectifier, no separate bias supply |
| Clamp | Active clamp output for an external PMOS, adjustable delay |
| Protection | Direct Flux Limit, overcurrent, overtemperature, precision UVLO with hysteresis |
| Input | 8 V and up, limited only by external components |
| Start-up | Adjustable start-up frequency and soft start, linear regulator controller |
| Package | 16-lead MSOP |
| Vendor status | Recommended for new designs |
Two questions buyers ask
Can this part run the converter on its own?
No. It is the start-up and primary side half; the regulation loop lives in the LTC3766 on the secondary side, and the two are bought together. A board that fits only this device has no feedback path and no synchronous rectifier control.
What sets the maximum input voltage?
The external components. The controller itself has an 8 V floor and no upper limit in its own specification, so the input ceiling is the voltage rating of the MOSFETs, the clamp device, the transformer and the snubber. An offline converter at 400 V is possible, and every part around the controller then has to be rated for it.
Ordering and supply
The EMSE suffix is the 16-lead MSOP body on the industrial grade, and TRPBF is tape and reel, lead free. The family has eight part models, and because this device only makes sense next to the LTC3766, the two codes belong on the same purchase order and the same life cycle plan. A repair kit that carries one without the other is incomplete.
We supply this family for production and for repair. Start at the analog mixed signal ICs family page, compare a candidate against the power management cross reference, and where an isolated supply is being rebuilt against a schedule, the lead time arithmetic in component lead time solutions is the place to check the transformer as well as the controller.
LTC3765EMSE#TRPBF: the pulse transformer is a specified part, not an afterthought
The controller multiplexes gate drive signals and bias power across the isolation barrier through a small pulse transformer, and an on-chip bridge rectifier extracts the drive bias from that transformer. The consequence is that a separate bias supply for the secondary side disappears from the bill of materials, and the transformer becomes a component with a specification of its own: turns ratio, interwinding capacitance, isolation rating and the pulse fidelity that carries the gate signals. Two suppliers of otherwise identical forward converters can differ only in that part, and a substitute chosen on price alone is the usual reason a rebuilt unit fails its isolation test.
Start-up is a sequence, and the parts around it are in the sequence
The device carries a linear regulator controller for fast start-up, an adjustable start-up frequency, soft start, a precision undervoltage lockout with adjustable hysteresis, overcurrent protection and thermal protection. The 8 V floor in the specification is the controller's own supply, and the ceiling is set entirely by the external components: the MOSFETs, the clamp device, the transformer and the snubber. That is why the same order code appears in a 48 V telecom converter and in a 400 V offline supply, and why a question about maximum input voltage has to be answered by naming those parts rather than by quoting the controller.
| Function | On the controller | Still a discrete part |
|---|---|---|
| Primary gate drive | High speed drivers with delay adjustment | The MOSFETs and their gate resistors |
| Active clamp | Drive with adjustable delay | The clamp MOSFET, its capacitor and the snubber |
| Barrier crossing | Multiplexed drive and bias through a pulse transformer | The pulse transformer itself |
| Bias for the far side | On-chip bridge rectifier | Nothing, which is the point of the arrangement |
| Flux control | Direct flux limit to prevent saturation | The transformer's saturation margin and the timing components |
| Secondary control | Not in this part | The LTC3766 controller and the synchronous rectifiers |
Direct flux limit is the protection that keeps the transformer out of saturation
A forward converter saturates when the volt second product across the primary exceeds what the core can hold, and a start-up transient or a short circuit on the secondary is exactly when that happens. The active clamp with delay adjustment resets the core, and the flux limit stops the drive before the reset budget is exhausted. In practice that turns a fault from a destroyed transformer and a shorted primary switch into a converter that stops and restarts, which is the difference between a field replacement and a repair. The protection is inside the controller, but it is only as good as the clamp capacitor and the delay set around it.
Isolated supply parts share long lead times with their transformers, which is worked through on component lead time solutions; the family index is on the analog and mixed-signal ICs page and the nearby regulator options are on the power management cross reference.
Request Quote — In Stock, 100% New & Original, Full Warranty