The LTC3615MPUF#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC3615MPUF dual 3 A converter across the extended range
The LTC3615MPUF is the MP temperature letter of the dual 3 A synchronous buck in the 4 by 4 mm QFN-24 or eTSSOP-24: 2.25 V to 5.5 V of input, outputs to 0.6 V, plus or minus 1 percent accuracy, up to 4 MHz, phase shift selectable at 0, 90 or 180 degrees, and 130 uA of quiescent current in Burst Mode. The MP letter buys the widest guaranteed window in the family, and that window is the only reason to specify this code over the I version.
What the letter changes and what it does not
The electrical table stays the same across the temperature letters: the same 3 A per channel, the same 0.6 V minimum output, the same 4 MHz ceiling and the same 1 uA shutdown. What moves is the range over which those numbers are guaranteed. A rail pair that has to start at minus 40 C and hold at 105 C is a different requirement from one that runs in a cabinet, and the MP letter is the answer when the enclosure is not the whole story.
The multiplier that follows from the currents
| Condition | Figure | Note |
|---|---|---|
| Dual 3 A through 1 mohm of copper | 3 mV per channel | the copper has to be sized for current, not drop |
| 1.8 V and 1.2 V at 3 A each | 9.0 W out, 1.0 W loss at 90 percent | one body, one pad |
| Quiescent, Burst Mode | 130 uA | 1.14 Ah over a year |
| Shutdown | at or below 1 uA | 0.009 mAh over a year |
| DDR mode | 1.5 A per channel each way | half the buck rating |
The 1 W of loss in a 4 by 4 mm body is the thermal specification of the whole board section, and the MP letter does not change it. What the letter changes is whether the part is guaranteed to keep the loop stable and the reference accurate at the ends of the range, which on a cold start from minus 40 C is the difference between a rail that comes up and one that hiccups.
Frequency and interleaving in a cold start
At 4 MHz the period is 250 ns and a 5 V to 1.2 V channel runs 60 ns of on time, so the duty is close enough to the minimum on time that the frequency deserves a second look at the low output voltage. At 180 degrees of phase shift the two channels interleave, which halves the input ripple current and lets a smaller input capacitor meet the same ripple target. That saving is usually worth more than the last 500 kHz of switching frequency, because it removes copper and components rather than adding them.
Where this code fits
Industrial and outdoor equipment with a wide ambient range, dual rail analog sections that have to start cold, and any product where the datasheet window rather than the enclosure temperature is the binding constraint. The dual channel with interleaving suits a processor core plus an I/O rail from a 3.3 V or 5 V backplane.
Cold start and the 0.6 V floor
At minus 40 C the parts that move are the reference, the oscillator and the FET on resistance, and the one that matters first is whether the rail comes up at all. The output floor is 0.6 V and the input range starts at 2.25 V, so a 0.6 V rail from a 3.3 V backplane is an 18.2 percent duty, which at 2 MHz is a 90.9 ns on time and at 4 MHz is 45 ns. Both are workable, but the higher frequency leaves less room for the minimum on time and for the gate drive delay at cold, so a board build that has to start at the bottom of the temperature range should be checked at the frequency it will actually run rather than at the highest one the part allows. The MP letter is what guarantees the loop and the reference across that range; it does not change the duty cycle arithmetic, and it does not make a 45 ns on time easier to hold.
Sourcing notes and next step
Ask for the full code including the temperature letter and the package suffix, since the same die appears in the QFN and the eTSSOP with different thermal behaviour. Our ADI second source page lists what we can quote, the lead time page covers the schedule case, and the analog and mixed signal category holds the rest of the family.