Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC2864HDD-1#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC2864HDD-1#TRPBF: Full Duplex RS485 That Survives 60 V on the Line

The LTC2864HDD-1#TRPBF is a full duplex RS485 and RS422 transceiver with a driver enable, operating from 3 V to 5.5 V and rated to 20 Mbps. The interface pins survive faults to plus or minus 60 V in every mode including power down, the input common mode range is plus or minus 25 V guaranteed, ESD is plus or minus 15 kV on the interface pins and plus or minus 8 kV on the others, the receiver is fully fail safe so an open, shorted or terminated but undriven line gives a defined output, and the input impedance supports 256 nodes on one bus. The part is pin compatible with the LT1785 and LT1791, comes in DFN and leaded packages, and an MP grade option covers minus 55 to 125 C.

Sixty volts of fault protection is not a datasheet decoration. A transceiver on a building network sees the mains through a miswired cable, an inductive kick from a motor on the same tray, or a ground fault that puts 48 V of telecom battery on the pair. A part that survives that with the power off is the difference between a service call and a burned node.

20 Mbps is a 50 ns bit, and 60 V is 12 times the 5 V rail

At 20 Mbps one bit is 50 ns, so the driver, the cable and the receiver all have to settle inside that window. A 100 m twisted pair at about 5 ns per metre is 500 ns of flight time, which is ten bit periods, so the 20 Mbps rate belongs on short backplanes and not on long field buses. The 250 kbps version of the same family is the one for a 1000 m run, and it is 80 times slower on purpose.

The fault rating is 60 V against a 5 V rail, a factor of 12, and against a 3.3 V rail it is a factor of 18. The common mode range of plus or minus 25 V is five times the 5 V rail, which is what allows two nodes with a large ground potential difference to talk to each other. Both figures are quoted for all modes of operation, including power down, so a node that is unpowered still presents a high impedance and does not load the bus.

Full duplex with an enable, and 256 nodes

Full duplex means the driver and the receiver are independent, so a node can transmit and receive at the same time on a four wire bus. The -1 suffix is the enabled version at 20 Mbps; the same family carries a -2 suffix at 250 kbps, a half duplex LTC2862 and a full duplex LTC2863 without the enable, and a LTC2865 that adds a separate logic supply pin so a 1.65 V to 5.5 V processor can talk to a 5 V bus without level shifting.

256 nodes is 1/8 unit load each, eight times the 32 node loading of a standard RS485 receiver. On a retrofit where a segment already carries more than 32 devices, the higher input impedance is what allows another node to be added without a repeater.

FunctionFull duplex RS485 and RS422 transceiver with driver enable
Supply3 V to 5.5 V
Data rate20 Mbps, a 50 ns bit, on this suffix
Fault protectionPlus or minus 60 V on the line in all modes, including power down
Common modePlus or minus 25 V guaranteed, five times a 5 V rail
ESDPlus or minus 15 kV on interface pins, plus or minus 8 kV on the rest
ReceiverFully fail safe on open, shorted and terminated but undriven inputs
Loading256 nodes, 1/8 unit load each
CompatibilityPin compatible with LT1785 and LT1791
Package and gradeDFN on this code, leaded options, MP grade to minus 55 C

Two questions buyers ask

Does 60 V protection replace external transient protection?
No. It covers a sustained overvoltage on the line, which is what a miswire or a ground fault produces, and it survives ESD at 15 kV. A lightning induced surge on a long outdoor cable is a different event with a different energy, and a gas tube or a TVS at the connector is still part of the circuit. The internal protection is what keeps the part alive between the surge and the replacement of the external device.

Can I use the 20 Mbps part at 115.2 kbps?
Yes, a faster transceiver works at a slower rate, with one caveat: the edge rate is faster and the emissions are higher. The 250 kbps suffix exists because a slower edge radiates less, and on a long cable the slower part is often the one that passes emissions without ferrites.

Ordering and supply

The HDD-1 suffix is the DFN body on the high temperature grade with the 20 Mbps rate and the enable, and TRPBF is tape and reel, lead free. The rate, the duplex and the enable are all encoded in the suffix, so an order that says LTC2864 without the suffix does not identify a part. The 250 kbps version is a different code with the same pinout, which is convenient for a board that has to pass emissions late in a program.

We supply this family for production and for repair. Start at the analog mixed signal ICs family page, compare a candidate against the pin to pin cross reference, and where the transceiver sits in a medical or building system, the component list behind medical device components covers the isolation and protection parts around it.

Request Quote — In Stock, 100% New & Original, Full Warranty