Contact Us

LTC2054HVIS5#TRPBF

Brand: Analog Devices
Analog Devices LTC2054HVIS5#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC2054HVIS5#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC2054HVIS5#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC2054HVIS5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC2054HVIS5 for instrumentation that runs hot and cold

The LTC2054HVIS5 is the industrial letter of the high voltage single zero drift amplifier: 11 V total supply, common mode from the negative rail to 0.5 V below the positive rail, rail to rail output, 3 uV maximum offset, 30 nV per degree C maximum drift, 150 uA maximum supply current and a 500 kHz gain bandwidth. The HV part is what lets it sit on a plus and minus 5 V rail, and the I letter is what lets it do that in a cabinet rather than on a bench.

The two grades in one table

The data sheet carries separate columns per temperature grade, and the headline offset and drift figures are attached to the industrial column. A C grade board that runs at 60 C is inside its own column and fine; the same board specified with the C part but qualified at 85 C is being qualified outside the column it was bought in. That is the trap on this family, because the part number differs by one letter and the datasheet looks identical at a glance.

ItemFigureConsequence
Supply2.7 V to plus or minus 5.5 Vplus and minus 5 V rail with 0.5 V of headroom
Common modeV minus to V plus minus 0.5 Vplus 4.5 V of a plus 5 V rail is the top
Offset3 uV maximum0.16 LSB at 18 bits on 5 V
Drift30 nV per degree C maximum3.75 uV over 125 degrees
Supply current150 uA maximum1.31 Ah over a year

Rejection at a 10 V common mode

A common mode rejection ratio of 130 dB typical is a factor of 3.16 million, so 10 V of common mode becomes about 3.2 uV referred to the input. That is the same order as the offset, which is why a zero drift part holds its accuracy in a high side sensing circuit where the common mode moves. The number is typical, not guaranteed, so a worst case budget should use the guaranteed minimum from the specification table, and that minimum is a lower figure than 130 dB.

Where the current actually goes in a 4 to 20 mA loop

A loop powered transmitter has a total budget of 4 mA and the amplifier is a rounding error inside it: 150 uA is 3.75 percent of the budget, and a second amplifier doubles that. The reason to use this part in a loop is not the current, it is the offset stability over the ambient swing of a field enclosure, which is exactly the term that a general purpose amplifier with 10 uV per degree C drift cannot hold. At 10 uV per degree C over 85 degrees the drift alone is 850 uV, which is 11 codes of a 16 bit converter on 5 V.

Chopping and the noise floor

Zero drift means the offset is modulated and corrected continuously, and the price is a noise floor with a 1/f corner that sits at a very low frequency. The 0.01 Hz to 10 Hz figure is 1.6 uV peak to peak, which is the band that matters for a weighing scale or a thermocouple. Above 10 Hz the noise density is the relevant number and it is not the same as the peak to peak figure, so a channel that samples at 1 kHz should be budgeted from the density, not from the 0.01 Hz to 10 Hz number.

Multiplexed inputs and the recovery question

An instrumentation front end that switches between channels asks a question the DC specifications do not answer: how long after a large step does the amplifier settle back into its offset window. A chopper has to recover its correction loop after an overload, and that recovery is a specification rather than a rule of thumb. If a channel is switched from a 10 V common mode node to a millivolt thermocouple, the settling time of the amplifier plus the filter is what sets the scan rate. Budget it from the data sheet and measure it on the board, because the RC at the input is part of the answer and it is not in the data sheet.

Questions that come up on this part

What is the difference between this and the non HV part? Eleven volts total against six. Everything else is the same die and the same specifications, so the choice is entirely about the rail the board has.

Is 150 uA really the maximum? Yes, per amplifier, and it is a maximum rather than a typical. A four channel front end built from four singles is 600 uA, which is a real line in a loop powered budget.

How does the common mode rejection hold up over temperature? The 130 dB figure is typical. A worst case budget has to use the guaranteed minimum from the specification table, and that minimum is lower. At a 10 V common mode a 100 dB minimum would be 100 uV referred to the input, which is thirty times the offset, so the rejection term can dominate a high side measurement.

Can it drive a 16 bit converter directly? Only with an RC between them. The output is rail to rail but the amplifier has a finite output impedance at the chopping frequency, and a switched capacitor input samples that impedance as a charge error.

Sourcing notes and next step

Write the full order code on the purchase order, including the HV and the I, because the non HV part is a 6 V device and a substitution would put 10 V across it. Our medical device components page covers the long life and traceability route, the ADI second source page lists alternatives against a code, and the analog and mixed signal category holds the rest of the family.

Request Quote — In Stock, 100% New & Original, Full Warranty