Contact Us

LTC1562IG#PBF

Brand: Analog Devices
Analog Devices LTC1562IG#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC1562IG#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTC1562IG#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC1562IG#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC1562IG#PBF: Four Second Order Sections, No Clock, and 150 kHz of Continuous Time

The LTC1562IG#PBF is a quad universal filter: four independent second order sections in one package, each programmed by three external resistors for centre frequency, Q and gain, with a centre frequency range of 10 kHz to 150 kHz and no clock anywhere in the signal path. Lowpass and bandpass outputs come out of every section, a highpass response is available by replacing one resistor with a capacitor, and allpass, notch and elliptic responses can be built from the same blocks. The typical centre frequency accuracy is plus or minus 0.5 percent, the A grade tightens that to plus or minus 0.3 percent, and the part runs from a single 5 V supply or a plus or minus 5 V pair with rail to rail inputs and outputs.

Why a continuous time filter is still the right answer

A switched capacitor filter is smaller and tunes with a clock, and it also puts a sampling artefact into the signal path that has to be filtered again. This part does neither: the response is set by resistor ratios, the noise is set by the RC network and the internal amplifiers, and there is no clock feedthrough to appear as a spur in a spectrum. On a 16-bit or 18-bit acquisition channel ahead of a converter, that difference is the whole reason the part exists, because a spur at the clock frequency is indistinguishable from a real signal and no amount of averaging removes it.

The four sections cascade into any shape. All four in series is an eighth order filter with a 48 dB per octave roll off, two pairs is a dual fourth order for I and Q channels, and one section on its own is a single second order notch or a bandpass for a carrier. The signal to noise ratio is 103 dB from a plus or minus 5 V supply at a Q of 1, 97 dB from a single 5 V supply, and the signal to noise plus distortion is 96 dB at a 20 kHz input, which puts the part in the 16-bit class on its own without help from the converter.

SectionsFour independent second order blocks, cascadeable
Centre frequency10 kHz to 150 kHz, set by one resistor per section
AccuracyPlus or minus 0.5 percent typical, plus or minus 0.3 percent on the A grade
ResponsesLowpass, bandpass, highpass, notch, allpass, elliptic
Signal to noise103 dB at plus or minus 5 V, 97 dB at single 5 V, Q of 1
Signal to noise plus distortion96 dB at 20 kHz input, plus or minus 5 V
DC accuracy3 mV typical, 39 LSB at 16 bits on a 5 V span
SupplySingle or dual, 5 V to 10 V total
ShutdownZero power shutdown mode

Where 150 kHz stops, and what a sampling rate has to be

The 150 kHz ceiling is a property of the internal amplifiers rather than of the resistors, and a section programmed above it stops behaving like the equations say. That ceiling also sets the converter behind it: a 150 kHz corner needs a sampling rate of at least 300 kSPS for the corner to sit below Nyquist, and at 250 kSPS the top 25 kHz of the range folds back into the passband. A board that pairs this filter with a 250 kSPS converter and uses the top of the range has an aliasing path that no filter order fixes, because the fold happens before the converter rather than inside it.

The 3 mV of DC accuracy is the other number that has to be read in the right units. On a 16-bit converter with a 5 V span it is 39 least significant bits, which is fine for an AC channel and not fine for a DC one, so a channel that measures a static quantity needs either a servo loop around the filter or a separate DC path. The part is specified for AC performance, and using it as a DC amplifier and calling the offset an error is reading a filter data sheet as an amplifier data sheet.

Centre frequency tolerance is worth putting in the same frame. Plus or minus 0.5 percent at a 100 kHz corner is plus or minus 500 Hz, which matters when the corner sits next to a 50 Hz or 60 Hz line component or when two channels have to match for I and Q. The A grade halves the spread, and resistor tolerance and temperature coefficient add to it, so a channel that needs the corner within 100 Hz is trimmed at test rather than bought as a grade.

Programming the sections, and the parts that are not resistors

Each section takes three resistors for centre frequency, Q and gain, and the data sheet formulas give the values directly. The resistors set the transconductance of the internal integrators, which is why the corner is as accurate as the resistors and as stable as their temperature coefficient: 100 ppm per degree C resistors at a 100 kHz corner move it 10 Hz per degree C, which over 50 degrees is 500 Hz and the same size as the grade tolerance. A board that buys the A grade and fits 5 percent carbon resistors has paid for accuracy it cannot use.

The internal amplifiers are not ideal at the top of the range either. At 150 kHz the loop gain available for the Q setting is lower than at 10 kHz, so the achieved Q of a high Q section drifts from the programmed value and the passband gain moves with it. Sections that need a Q above about 10 belong at the low end of the range, and the eight order cascade is the way to get a steep skirt at the top rather than one high Q section.

Two questions buyers ask

Can it replace an LC filter module without a board change?
No. The pinout, the supply and the resistor programming are all different, and an LC module has no supply current and no maximum input level of this kind. The replacement is a board change with a smaller footprint and a repeatable response, not a socket swap.

Does it need an anti-aliasing filter in front of it?
The part is the anti-aliasing filter when it sits ahead of a converter, and it still needs a passive RC in front of its own inputs to keep out-of-band energy from reaching the input stage. That RC is a resistor and a capacitor at each input and it also sets the noise contribution of the source, so it belongs in the budget rather than being added at the end.

Ordering and supply

The LTC1562IG#PBF is the SSOP package, industrial temperature, lead free code. Cross references fail on the frequency range and on the programmability rather than on the package: a fixed frequency filter module with the same corner is not a substitute for a part whose Q and gain are set per section, and a switched capacitor part with the same corner brings a clock into a signal path that had none. The replacement also has to keep the rail to rail input range if the channel is single supply.

We hold and source this family for production quantities and for repair lots. Start from the family page for analog mixed signal ICs, check a proposed alternative against the ADC and DAC cross reference, and for instrument channels that carry a patient connection the parts and qualification route in medical device components is where the filter is checked against the isolation and approval requirements of the whole channel.

Request Quote — In Stock, 100% New & Original, Full Warranty