Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC1562IG-2#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC1562IG-2#TRPBF: Four Second Order Sections, No Clock, and 103 dB of Signal to Noise

The LTC1562IG-2#TRPBF is a continuous time filter with four independent second order sections in one package, a centre frequency range of 10 kHz to 150 kHz, and rail to rail inputs and outputs. Each section is programmed by three external resistors for centre frequency, Q and gain, and provides lowpass and bandpass outputs, with highpass available when one resistor is replaced by a capacitor. Centre frequency accuracy is plus or minus 0.5 percent typically, plus or minus 0.3 percent on the A grade, signal to noise ratio is 103 dB on a plus or minus 5 V supply at a Q of 1 and 97 dB on a single 5 V supply, signal to noise plus distortion is 96 dB with a 20 kHz input, direct current accuracy is 3 mV typical, the supply is 5 V to 10 V total, and a shutdown mode removes the supply current.

The feature that sells this part is the absence of a clock. A switched capacitor filter needs a clock, and that clock and its harmonics mix with the signal and with any switching supply on the board, which is exactly what a 16 to 18 bit channel cannot tolerate. A continuous time filter has no such mechanism, and its cutoff is set by resistor ratios rather than by a clock frequency.

One hundred and three decibels is 17.1 bits

A signal to noise ratio of 103 dB is 17.1 bits, and on a single 5 V supply the 97 dB figure is 16.1 bits. That is the dynamic range the filter leaves for the converter behind it, and it is why the part appears in 16 and 18 bit systems: a filter with 80 dB would be the limiting element in a 16 bit channel, and this one is not. The 96 dB of signal to noise plus distortion with a 20 kHz input is the figure that includes the distortion of the sections, and it is 3 dB below the noise alone, which tells you the distortion is at a similar level to the noise at that frequency.

Direct current accuracy of 3 mV is 19.7 LSB at 16 bits on a 10 V span, so the filter cannot be used as the direct current element of a 16 bit channel without an offset trim or an alternating current coupling capacitor. That is typical of a continuous time filter with an operational amplifier inside each section: the offset of the internal amplifiers appears at the output and is not trimmed.

SectionsFour independent second order blocks, cascadable to one eighth order or two fourth order
Centre frequency10 kHz to 150 kHz on the family, programmed by three resistors per section
AccuracyPlus or minus 0.5 percent typical, plus or minus 0.3 percent on the A grade
Signal to noise103 dB on plus or minus 5 V, 97 dB on a single 5 V supply, 17.1 and 16.1 bits
Distortion96 dB signal to noise plus distortion with a 20 kHz input
Offset3 mV typical, 19.7 LSB at 16 bits on a 10 V span
ResponsesLowpass and bandpass per section, highpass with a capacitor, notch and elliptic by combination
Supply5 V to 10 V total, single or dual, with a shutdown mode
Package16-lead SSOP and the wide body option

Half a percent at 100 kHz is 500 Hz, and that is the number to work against

At a 100 kHz centre frequency the plus or minus 0.5 percent tolerance is 500 Hz, and on the A grade it is 300 Hz. In a 20 kHz band that is 2.5 percent of the bandwidth, which is acceptable for an anti alias filter with a guard band; in a 10 kHz band it is 5 percent, and a filter that was specified to start rolling off at a particular frequency may be rolling off earlier or later than the calculation says. The tolerance is a ratio of resistors inside the part, not a trimmed absolute frequency, so it tracks with temperature better than an absolute reference would.

The Q also sets the bandwidth of each section, and a Q of 10 at 100 kHz is a 10 kHz bandwidth. Cascading sections multiplies the orders but leaves each section's own Q and centre frequency as separate settings, which is how a Butterworth, Chebyshev or elliptic response is built from the same four blocks. A second order section rolls off at 12 dB per octave, so an eighth order cascade is 48 dB per octave, which is what makes a 100 kHz anti alias filter practical for a 250 kSPS converter.

Two questions buyers ask

Does the -2 order code have the same frequency range?
The family figures quoted here are for the 10 kHz to 150 kHz member, and the -2 order code is a separate variant with its own data sheet. Its usable centre frequency range and its resistor equations have to be read from that document rather than assumed from this page, because the internal capacitor values differ between variants and the resistors that set 100 kHz on one will not set it on the other.

Why not use a switched capacitor filter?
Because of the clock. A switched capacitor filter aliases any input content near its clock frequency into the band, and a board with a 1 MHz converter clock and a 500 kHz switching supply has two sources that can land in the passband. A continuous time filter has no sampling mechanism, so its rejection is set by the analogue sections alone. The price is that the centre frequency is set by resistors and cannot be tuned by changing a clock.

Ordering and supply

The IG-2 suffix is the 16-lead SSOP in tape and reel. Substitution traps are the variant, the grade and the resistor network: a different variant needs different resistors for the same centre frequency, and a part without the A grade tolerance is 0.5 percent rather than 0.3 percent. Both differences show up as a shifted cutoff rather than as a dead channel.

We hold and source this family for production and repair lots. Start at the analog mixed signal ICs family page, compare a candidate against the ADC and DAC cross reference, and where a filter has to be replaced on an existing board, the order in how to verify a drop in replacement starts with the variant and the resistor values.