LT8650SHV#PBF
Product Specifications
LT8650SHV#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8650SHV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8650SHV#PBF: the dual 4 A regulator specified to a 150 C junction
The LT8650SHV#PBF is the H grade member of the dual channel Silent Switcher family: two 4 A synchronous step-down channels, 3.0 V to 42 V input, 6.2 uA burst mode quiescent current, in a 32-lead 4 mm by 6 mm laminate QFN, specified over minus 40 C to 150 C junction instead of the 125 C that the E and I grades carry. In the order table the H grade appears in both the standard column and the automotive column, and the difference between those two columns is the controlled process flow, not the temperature.
The numbers that come with the grade
| Grade on this code | H, minus 40 C to 150 C junction |
| Channels | two, 4 A each simultaneously, 6 A on either channel |
| Input range | 3.0 V to 42 V |
| Quiescent current | 6.2 uA burst mode, internal compensation |
| Quiescent current, external VC | 90 uA sleep plus 50 uA per channel |
| Minimum switch on time | 40 ns |
| Switching frequency | 300 kHz to 3 MHz |
| Efficiency | 94.6 percent at 2 A, 12 V to 5 V at 2 MHz |
| Thermal resistance | 16.18 C/W junction to ambient |
| Package | 32-lead 4 mm by 6 mm laminate QFN, MSL 3 |
| Automotive flow | available as LT8650SHV#WPBF |
What another 25 C of junction actually buys
The 25 C is not a marketing margin, it is the difference between a part that is inside its limits on a hot board and one that is not. Consider both channels loaded at 4 A from 12 V, one into 5 V and one into 3.3 V. At the published efficiencies the two together dissipate roughly 2.6 W, and against 16.18 C/W that is a 42 C rise over ambient. On an 85 C ambient board the junction lands near 127 C, which the E grade does not cover and the H grade covers with 23 C to spare. On a 105 C ambient, which is where a sealed automotive or industrial box can sit, the H grade is the only member of the family that is inside its rating at that load.
The other side of the same arithmetic is that the grade does not create thermal capacity. If the enclosure is already at 120 C ambient, the H part has 30 C of junction rise available and the same 2.6 W puts it over. The H grade moves the limit, it does not remove it, and a board that needs 2.6 W of dissipation inside a hot box still needs copper, vias and air, or a lower load, or a second chip sharing the work.
Where the 150 C figure changes component choices
A 150 C junction rating only helps if everything around the regulator also survives. The inductor is the first item: a 1 uH part that is rated to 125 C will be the limiting component long before the regulator reaches its own limit, and the saturation current has to hold at the hot end, not at 25 C. The output capacitor is the second: ceramic capacitance falls with temperature and with dc bias, so the 47 uF that gave 3 mV of ripple at room temperature is a smaller number of microfarads at 125 C, and the loop has to stay stable with the smaller value.
The third item is the feedback divider and the enable threshold. Both are resistor ratios and both drift with the resistor temperature coefficient, so a 0.1 percent divider at 25 C is not a 0.1 percent divider at 150 C unless the parts were chosen for it. None of this is in the regulator data sheet, and all of it decides whether the 150 C grade is doing any work in the product.
Two questions buyers ask
Is the H grade the same die as the E grade? It is the same part in the same package with a different temperature guarantee, and the order table lists them as separate order codes with the range printed against each line. The practical consequence is that an E part cannot be substituted where an H part was qualified, because the guarantee is the thing that was bought.
Which code do I need if the product is also automotive? LT8650SHV#WPBF. That is the H grade with the W suffix, which carries the controlled process flow the data sheet reserves for automotive applications. This code, without the W, is the industrial H part and it is the correct choice for an industrial build that simply runs hot.
Sourcing notes and next step
Give us the grade letter, the temperature the enclosure actually reaches and the load per channel, and the quote will be against a code that survives the arithmetic. Parts that are stocked as E grade cannot be released against an H grade requirement, which is a substitution question rather than a price question. The power management cross reference page explains how a grade change is handled, the component cost page covers what a grade step does to price, and the analog and mixed signal category holds the rest of the range.
Request Quote — In Stock, 100% New & Original, Full Warranty