LT8614HUDC#TRPBF
Product Specifications
LT8614HUDC#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8614HUDC#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8614HUDC#TRPBF: the 150 C grade of the 4 A Silent Switcher
The LT8614HUDC#TRPBF is the H grade of the 4 A, 42 V Silent Switcher in the 18-lead 3 mm by 4 mm QFN. The H suffix marks the higher junction temperature grade in this family, 150 C against the 125 C of the E and I grades. Everything else is the same converter: 3.4 V to 42 V input, 4 A output, 2.5 uA in burst mode, a 30 ns minimum on time, 125 mV of dropout at 1 A and 200 kHz to 3 MHz from one resistor.
What the 150 C grade is for
| Grade on this code | H, 150 C junction |
| E and I grades in the family | 125 C junction |
| Input range | 3.4 V to 42 V, unchanged by the grade |
| Output current | 4 A |
| Quiescent current | 2.5 uA in burst mode |
| Minimum on time | 30 ns |
| Dropout | 125 mV at 1 A |
| Package | 18-lead 3 mm by 4 mm QFN |
| Automotive | a separate W code, not this one |
A rating is not a thermal budget
The grade guarantees the part to a 150 C junction; it does not hold the junction there. At 94 percent efficiency a 5 V 4 A output is 21.3 W in and 1.28 W of loss in an 18-lead QFN, and that heat leaves through the exposed pad, so the copper under the part and the via field set the junction more than the grade letter does. The 18-lead body in this family is specified at 40 C/W junction to ambient and 12 C/W junction to the pad on a JEDEC board, which turns 1.28 W into a 51 C rise; a well coppered board does better and a two layer board does worse. In a 105 C ambient the junction lands near 156 C at 40 C/W: outside the H rating, which is the point at which the frequency and the copper have to change.
That last point is the one that separates a grade decision from a thermal decision. Operating life in this family is derated above 125 C junction, so a part that runs at 143 C continuously does not carry the same expected life as the same part at 110 C, even though both are inside the H guarantee. A product that needs the H grade to pass a temperature chamber test and then runs near the top of the range has moved the reliability question into the qualification report. The usual answers are a lower switching frequency, which cuts switching loss, or two phases sharing the load.
Hot enclosure, cold start, and the parts around it
An H grade part in a sealed enclosure is usually paired with capacitors that are not rated for the same temperature. A ceramic output capacitor with a high dielectric constant loses most of its capacitance at 125 C and its DC bias derating is worse at the top of the range; an aluminium electrolytic loses life far faster than the regulator. The 10 uF minimum the data sheet asks for is a floor at 25 C, and the value that matters is the one at the operating temperature and the operating voltage.
At the cold end the same board is starting at minus 40 C, where the input capacitors have more capacitance than at 25 C and the ESR is lower, so the input loop is not the problem. What does move is the reference and the enable threshold, which the H grade guarantees over the range. The 1 V enable threshold with its hysteresis is what sets the input undervoltage lockout, and a divider built at 25 C has to be checked against the threshold window at both ends of the range.
Two questions buyers ask
Can the H grade drop into an E grade footprint? Yes: same die, same pinout, same external components, same frequency resistor. A board qualified with the E part accepts the H part, and the reverse is a specification change even though the two parts are visually identical on the reel. The H code is a separate order line, so the swap has to go through the bill of materials rather than through the loader.
Is this the automotive part? No. Automotive availability comes from a W suffix on a controlled process flow, and those codes are listed separately in the order table. An H grade without the W is an industrial part with a 150 C guarantee; it carries no automotive reliability report and a tier one audit will reject it on that basis alone.
Sourcing notes and next step
Quote the grade letter explicitly and give the ambient the board actually sees, because the E, I and H codes have different lead times and one cannot be released against another. Our drop in replacement page explains how a grade substitution is verified, the power management cross reference page shows how a higher grade is matched when the H line is short, and the analog and mixed signal category holds the rest of the 42 V range.
Request Quote — In Stock, 100% New & Original, Full Warranty