LT8610EMSE#TRPBF
Product Specifications
LT8610EMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8610EMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT8610EMSE#TRPBF: the industrial E grade, and what it measures
LT8610EMSE#TRPBF is the E grade of the LT8610 in the 16-lead MSOP, on tape and reel, without the automotive release. It is the code most often quoted for instrumentation, point of load rails and general 12 V or 24 V industrial work, and its published efficiency and standby numbers are what make it a default.
Published values
| Parameter | Value |
|---|---|
| Grade | E, tested from 0 C to 125 C |
| Input voltage | 3.4 V to 42 V |
| Continuous output | 2.5 A |
| Feedback reference | 0.970 V, 0.964 V to 0.982 V |
| Minimum on time | 50 ns |
| Switching frequency | 200 kHz to 2.2 MHz |
| Efficiency at 1 A | 96 percent, 5 V out from 12 V |
| Efficiency at 1 A into 3.3 V | 94 percent, from 12 V |
| Quiescent current | 2.5 uA regulating |
| Dropout | 200 mV at 1 A |
| Power good | plus or minus 9 percent |
| Thermal resistance | 40 C/W |
| Burst Mode ripple | below 10 mV peak to peak |
| Package | 16-lead MSOP with exposed pad |
What 96 percent means in watts
At 2.5 A into 5 V the converter delivers 12.5 W. At 96 percent the input is 13.02 W, so the loss is 0.52 W and the junction rise on 40 C/W is 21 C. The number looks like a specification and behaves like a thermal budget line.
At 1 A the same part is at its best point, where the switching loss is spread over fewer watts of output. The efficiency falls at light load into Burst Mode and at full load as the conduction loss in the switches grows with the square of the current, so a rail that spends most of its life at 2.5 A should be sized from the full load figure rather than the 1 A headline.
The reference is 1.86 percent, and the divider is the rest
0.964 V to 0.982 V is an 18 mV window, 1.86 percent, which lands as 61 mV at 3.3 V and 93 mV at 5 V. The load regulation term in the electrical table is a fraction of that, so the reference is the dominant DC error in a two resistor divider.
A 0.1 percent divider pair costs a few cents more than a 1 percent pair and removes about 1.3 percent of the error at the midpoint. On a 5 V rail feeding a 3.3 V point of load that is the difference between a 3 percent and a 2 percent specification, without changing the converter.
Standby, shutdown and the divider that eats both
2.5 uA regulating is 21.9 mAh over a year and 1 uA in shutdown is 8.76 mAh. Those are the numbers that decide whether a product can sit on a shelf for two years and still wake up.
The divider across the output is usually the larger term. A 100 kohm pair across 5 V draws 25 uA, ten times the converter's standby current, so a product that measures badly in standby should look at the feedback network and the power good pull up before it looks at the regulator.
The pages that answer this most often are the power management cross reference for the family alternatives, how to verify a drop in replacement for the acceptance test, and one stop BOM sourcing for the case where a replacement has to be fitted before the next build.
Two questions buyers ask
Does the E grade work below 0 C? It works, and the vendor assures the wider range by characterisation rather than by test. A product with a contractual cold start limit should use the I or H grade so the limit is backed by test.
Can two of these be paralleled for more current? Not directly. There is no current sharing between regulators, and the loop of the faster one wins. Two rails with their own feedback dividers, or a single part rated for the total, are the two supported answers.