LT8610AEMSE-5#TRPBF
Product Specifications
LT8610AEMSE-5#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8610AEMSE-5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT8610AEMSE-5#TRPBF: the E grade fixed 5 V rail
LT8610AEMSE-5#TRPBF is the E grade of the fixed 5 V LT8610A in the 16-lead MSOP, tested from 0 C to 125 C with the cold end assured by characterisation. It is the cheapest way to get 3.5 A at 5 V with no divider, and it suits a product that is specified from 0 C upwards and does not need the 150 C junction of the H grade.
Published values
| Parameter | Value |
|---|---|
| Grade | E, tested from 0 C to 125 C |
| Output | 5 V fixed, 4.94 V to 5.06 V |
| Input voltage | 3.4 V to 42 V |
| Continuous output | 3.5 A |
| Minimum on time | 30 ns |
| Efficiency | 95 percent at 1 A, 5 V out from 12 V |
| Top switch current limit | 5 A minimum |
| Bottom switch current limit | 3.4 A minimum |
| Quiescent current | 2.5 uA |
| Power good | plus or minus 9 percent |
| Thermal resistance | 40 C/W |
| Package | 16-lead MSOP, VOUT on pin 16 |
| Release | industrial, no W suffix |
Where an E grade is the right buy
A bench instrument, a point of load rail inside a rack and a 5 V accessory bus all live between 0 C and 70 C in service. The E grade is tested over the range those products actually see, and the cold end being assured by characterisation is a documented statement rather than a gap.
Where it is the wrong buy is a product with a contractual -20 C or -40 C start, or one that ships into a vehicle. Those need the I or H grade, and the price difference is the temperature test rather than a difference in silicon.
A fixed 5 V rail in a 12 V system
12 V to 5 V is 41.7 percent duty, so the 30 ns minimum on time is never reached and the full 2.2 MHz band is available. A 4.7 uH inductor at 2.2 MHz gives 0.66 A of ripple at 3.5 A, which is 19 percent of the load and a reasonable place to sit for a ceramic output bank.
The loss at full load is 0.92 W at 95 percent, 37 C of rise on 40 C/W, so a 125 C junction holds the load to a 88 C ambient. A rack inlet at 55 C leaves 33 C of margin, which is enough for a small enclosure without a heatsink.
Power good on a rail that is not the only one
The flag is plus or minus 9 percent, 450 mV at 5 V. On a board with several rails it is the sequencing signal rather than the accuracy signal: it tells a downstream converter that 5 V is usable, and the 9 percent window is wide enough that a load step does not reset the sequence.
For a load that cannot run below 4.75 V the flag is too coarse, and a supervisor with a published threshold and hysteresis belongs on the rail. The converter's own flag is referenced to its internal divider and is not trimmed for that job.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, component obsolescence management covers what to check before a part is dropped into an existing board, and one stop BOM sourcing is the route we take on a live shortage.
Two questions buyers ask
Is the E grade a 0 C part? It is guaranteed from 0 C to 125 C and characterised below 0 C. A product that must start cold needs the I or H grade.
Can the fixed 5 V part feed a 3.3 V point of load? Yes, through a second stage, but not at 5 V out directly. The output is fixed inside the part, so a 3.3 V rail needs its own order code or a second converter.