LT3980EMSE#TRPBF
Product Specifications
LT3980EMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3980EMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT3980EMSE#TRPBF: A 58 V Buck Where the On Time Gets Short
The LT3980 is a monolithic buck regulator that runs from 3.6 V to 58 V, rides through 80 V transients with its overvoltage lockout, delivers 2 A, and holds 85 uA of quiescent current in Burst Mode operation from 12 V to 3.3 V. The input range is the headline. The number that decides whether the board behaves is the on time at the switching frequency chosen, because a 58 V input and a 3.3 V output is a 5.69 percent duty cycle.
Duty cycle and the minimum on time
At 2.4 MHz, the top of the adjustable range, a 5.69 percent duty cycle is a 23.7 ns on time. Any regulator has a floor below which it cannot regulate cleanly, and a board that pushes the frequency to shrink the inductor while keeping a 58 V input is the classic case where the output starts to pulse skip or the current limit misbehaves. Dropping to 500 kHz makes the same duty cycle 114 ns, which is comfortable. The frequency range is 100 kHz to 2.4 MHz for exactly this trade.
Losses and light load
The internal switch is 200 milliohms, so 2 A of output current dissipates 0.8 W in the switch before switching losses. The catch diode current sense on the DA pin protects the circuit through a short or an input overvoltage even at high frequency, which is a protection path separate from the cycle by cycle current limit. In Burst Mode the quiescent current is 85 uA, so a 48 V input spends 4.1 mW to keep the rail alive, and the output ripple stays under 15 mV peak to peak while it does. Below 3 V of output the bias current comes from the input; above 3 V it can be drawn from the output, which is a small efficiency gain in a 3.3 V rail that is on all the time.
| Input range | 3.6 V to 58 V operating, 80 V transient with overvoltage lockout |
| Output current | 2 A maximum |
| Switch resistance | 200 milliohms |
| Switching frequency | 100 kHz to 2.4 MHz adjustable, synchronisable 250 kHz to 2 MHz |
| Quiescent current | 85 uA from 12 V to 3.3 V in Burst Mode, under 1 uA in shutdown |
| Output ripple | below 15 mV peak to peak in Burst Mode |
| Protection | catch diode current sense, thermal protection, soft start |
| Status | power good at 91 percent of the programmed output |
| Package | 16 lead MSOP with exposed pad, 3 mm by 4 mm DFN |
Where it fits
Industrial 24 V and 48 V rails, automotive and truck 12 V and 24 V systems that see load dump, battery backed equipment and any board where the input can be 40 V above the output. It is not a controller: the switch, the boost diode and the oscillator are on the die, so the external parts are the inductor, the catch diode, the input and output capacitors and the feedback divider.
Order code and availability
EMSE is the industrial grade in the MSOP body with the exposed pad, which is the thermal path for the 0.8 W of switch loss. The wider regulator family is on the analogue and mixed signal line card.
Common questions
Can it run from a 60 V rail? The operating range stops at 58 V, so a 60 V nominal rail is outside it even though the transient rating is 80 V. The overvoltage lockout protects against excursions, not against a steady state above the rating.
What sets the 2 A limit? The switch rating and the thermal path together. At 2 A and 0.8 W in a 16 lead MSOP, the exposed pad and the copper under it are part of the current rating, and a board with a small pad will reach thermal shutdown before it reaches 2 A in a hot enclosure.
Sourcing alternatives for the same rail are on the power management cross reference page, and short lead time options are on the BOM shortage recovery page.
LT3980EMSE#TRPBF: what the catch diode sense pin protects, and what it does not
The DA pin senses current in the catch diode, and that is what lets the regulator survive a short circuit on the output and an overvoltage on the input at the same time. The protection scheme is worth reading correctly: the operating input range is 3.6 V to 58 V, the overvoltage lockout carries the circuit through 80 V transients, and the 2 A output current is a switch and thermal limit rather than a promise at every input voltage. A 60 V nominal rail is outside the operating range even though the transient rating is 80 V, because the overvoltage lockout is a response to an excursion and not an operating point.
Ripple is a component choice, not a property of the part
The data sheet headline is under 15 mV peak to peak of output ripple, and that number follows from the inductor, the output capacitor and the switching frequency together. At 2.4 MHz the on time for 58 V to 3.3 V is 5.69 percent of a period, which is 23.7 ns, and at 200 kHz the same ratio is 284 ns. Inductor ripple current is the output voltage times one minus the duty cycle, divided by frequency times inductance, so the same 10 uH inductor gives about ten times the ripple at 200 kHz that it gives at 2.4 MHz. The 15 mV figure is a statement about a properly sized network at the top of the frequency range, not a guarantee for whatever inductor the board already had.
| Item | Published value | Arithmetic or consequence |
|---|---|---|
| Input range | 3.6 V to 58 V | A 60 V rail is out; 80 V is a transient, not a rail |
| Switch on resistance | 200 mohm | 0.8 W at 2 A, which is why the exposed pad is the current path |
| Switching frequency | 100 kHz to 2.4 MHz, synchronisable 250 kHz to 2 MHz | 24 times the frequency range, so the inductor scales with it |
| Quiescent current | 85 uA at 12 V in to 3.3 V out | 1.02 mW, about 8.9 Wh over a year |
| Shutdown current | Under 1 uA | 12 uW at 12 V, which is what makes a standby rail possible |
| Ripple | Under 15 mV peak to peak | Depends on inductor, capacitor and frequency, not on the die alone |
| Order code | EMSE, 16-lead MSOP with exposed pad | The E grade, industrial temperature, tape and reel |
Eighty five microamps is the reason this part exists next to a generic buck
A regulator that draws 1 mA of quiescent current on a 12 V input burns 12 mW doing nothing, which is 105 Wh over a year. At 85 uA the same rail burns 1.02 mW, and a product that sleeps for most of its life sees the difference in its standby budget rather than in its efficiency curve. The catch is that burst mode operation at light load is what delivers that figure, and burst mode puts a low frequency component on the output that a sensitive analogue rail may not accept. The data sheet makes the trade explicit by offering a synchronisable fixed frequency mode as the alternative, and a board that needs both a quiet rail and a low standby current usually ends up with two regulators rather than one compromise.
The regulator families are compared on the power management cross reference, the wider catalogue is on the analog and mixed-signal ICs page, and a replacement order for a long lead part starts at BOM shortage recovery.
Request Quote — In Stock, 100% New & Original, Full Warranty