LT3763EFE#PBF
Product Specifications
LT3763EFE#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3763EFE#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3763EFE#PBF: 20 A of Regulated Current, 1.2 A of Accuracy and a 2 W Sense Resistor
The LT3763 is a fixed frequency synchronous step-down controller that regulates output current up to 20 A over an output range from 0 V to 55 V, with a 6 V to 60 V input. It is built around an average current mode loop, so it holds inductor current rather than voltage, which is what lets it drive an LED string, a laser diode, a battery or a motor winding with the same part. Voltage regulation accuracy is 1.5 percent, current regulation accuracy is 6 percent, and the input and output currents can both be sensed and limited.
Published values
| Parameter | Value |
|---|---|
| Input range | 6 V to 60 V |
| Output range | 0 V to 55 V |
| Output current | Up to 20 A, average current mode |
| Current accuracy | Plus or minus 6 percent |
| Voltage accuracy | Plus or minus 1.5 percent |
| Switching frequency | 200 kHz to 1 MHz, synchronisable |
| Current sensing | Input and output, monitor and limit |
| Extra input | FBIN pin for peak power tracking |
| Faults | Open, short and C/10 detection, thermal shutdown |
| Shutdown current | Under 2 uA |
| Package | 28 lead FE with pad |
Six percent of 20 A is 1.2 A, and that is the real specification
A current regulation accuracy of 6 percent at a 20 A set point is 1.2 A of uncertainty. On an LED string driven at 20 A that is visible as a brightness difference between units, and on a laser diode it is outside the safe window unless the set point is derated. The accuracy is not an accident: it includes the tolerance of the external sense resistor, the offset of the current amplifier and the drift of both. A 0.5 percent sense resistor and a 1 percent amplifier offset together do not add up to 6 percent, which means most of the budget is spent where the customer cannot see it, in the amplifier offset over temperature. Anyone quoting 20 A from this part should quote the window, not the number.
The sense resistor is 2 W of the answer
At 20 A a 5 milliohm sense resistor dissipates 2 W. That is a real component, not a trace, and it sits on the board next to the inductor. Raising the resistance improves signal to noise and worsens efficiency; lowering it saves power and pushes the amplifier offset up as a fraction of full scale. At 20 A into a 12 V load, 240 W, the 2 W is 0.83 percent of the delivered power, which is the price of measuring current at this level at all.
48 V to 12 V is a 25 percent duty, so 250 ns at 1 MHz
From a 48 V input to a 12 V output the duty cycle is 25 percent, which at 1 MHz is a 250 ns on time, and the 20 A output draws 5.21 A from the 48 V rail at 96 percent efficiency. That ratio is comfortable for a synchronous buck, and it is the reason this part belongs on a 48 V backplane rather than on a 12 V one. The FBIN pin is the interesting extra: it accepts an input voltage signal so the loop can reduce current when the source sags, which is peak power tracking for a solar or a generator input without a second controller. The 55 V ceiling allows a 20 A pulse into a 3.4 V string of 68 W, and the C/10 detection makes the end of a charge cycle visible to the host without a shunt amplifier.
Where a 20 A stage has to be built as a block, the controller, the inductor, the MOSFETs and the sense resistor are bought together, which is what one stop BOM sourcing is for. Second sourcing the same function across brands is a control loop question before it is a pin question, covered in the power management cross reference, and a line that must not stop when one code goes short is in component obsolescence management.
Two questions buyers ask
Does the 6 percent apply to the voltage loop too? No. Voltage regulation is 1.5 percent and current regulation is 6 percent, and the two loops are separate. A battery charger that ends on voltage is inside 1.5 percent; a LED driver that holds current is inside 6 percent, and the difference decides whether the part can be used as a precision current source.
Can it drive a load at 0 V output? The output range starts at 0 V, which is what average current mode buys: the loop regulates current in the inductor, so a shorted or near zero output does not lose the control signal the way a voltage mode buck would. That is also why short circuit detection is a feature and not a protection afterthought.