LT3748EMS#TRPBF
Product Specifications
LT3748EMS#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3748EMS#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3748EMS#TRPBF: Isolated Flyback With Primary Side Sensing and a 148 V FET Problem
The LT3748 is a flyback controller, not a converter: it drives an external low side N channel MOSFET from an internally regulated 7 V supply, senses the isolated output voltage off the primary side flyback waveform, and needs neither a third transformer winding nor an optocoupler to close the loop. Input range is 5 V to 100 V, gate drive is 1.9 A source and sink, and the output is set with two external resistors. It runs in boundary mode, so the switching frequency follows load current and transformer magnetising inductance rather than a clock.
Published values
| Parameter | Value |
|---|---|
| Input range | 5 V to 100 V |
| Topology | Isolated flyback, boundary mode |
| Gate drive | 1.9 A source and sink |
| Internal gate supply | 7 V, INTVCC pin |
| Feedback | Primary side winding sensing, no opto, no third winding |
| Output setting | Two external resistors |
| Protection | Programmable soft start and undervoltage lockout |
| Package | 16 lead MSOP, high voltage, four leads removed |
| Qualification | AEC-Q100 stated for the family |
The reflected voltage is the number that fixes everything else
With a 4 to 1 turns ratio and a 12 V output, the primary side sees 48 V of reflected output voltage during the off time. Duty cycle is that reflected voltage divided by the sum of reflected voltage and input voltage: 50 percent at a 48 V input, 66.7 percent at 24 V, 32.4 percent at 100 V, and 90.6 percent at the 5 V bottom of the input range. Those four numbers describe the whole converter. The 90.6 percent at low line is the one that limits how low the input can go, because boundary mode needs the transformer to reset in the remaining 9.4 percent of the period. The 32.4 percent at 100 V is where the magnetising current ramps fastest and the peak primary current, not the duty, sets the current sense resistor.
148 V is what the external FET has to block
At a 100 V input the MOSFET holds the input voltage plus the 48 V reflected output, which is 148 V before any leakage spike is added. A 150 V device sits on the edge, a 200 V device is the honest choice, and the leakage inductance spike that arrives when the primary current is interrupted adds to both. Raise the turns ratio to 6 to 1 and the reflected voltage at a 48 V input becomes 72 V, which cuts the duty cycle and the primary current for the same output power but pushes the blocking voltage up, so the turns ratio is a trade between duty cycle range and FET rating, not a free improvement.
Output power is a few tens of watts: 24 V at 2 A is 48 W, which at 88 percent efficiency draws 2.27 A from a 24 V input. The 1.9 A gate drive is what makes that possible at boundary mode frequencies, because the gate charge has to move in a short off time. Isolated telecom and industrial supplies built around this part usually need the transformer and the FET sourced with the controller, and second sourcing the whole function is covered in the power management cross reference, with the vendor specific position in the ADI second source page and slow moving codes in lead time options.
Two questions buyers ask
Does primary side sensing hold regulation without an optocoupler? It samples the flyback pulse on the primary during the off time, which is proportional to output voltage through the turns ratio, so load regulation is held without a secondary side feedback path. The cost is that the sample includes the secondary diode forward drop and the leakage inductance ringing, so the output sits slightly high at light load and the diode choice is part of the accuracy budget.
Why boundary mode rather than a fixed frequency? Boundary mode lets the transformer reset completely every cycle, so a smaller magnetic can be used for the same power and there is no reverse recovery loss in the secondary diode. The price is a switching frequency that falls with load, which moves the EMI spectrum with the load current and has to be checked at both ends of the load range.