Contact Us

LT3680HMSE#TRPBF

Brand: Analog Devices
Analog Devices LT3680HMSE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3680HMSE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3680HMSE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3680HMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3680HMSE#TRPBF: 150 C Junction and What the Extra 25 K Is Actually Worth

The LT3680 comes in three temperature grades and they are not three different parts. The E grade is guaranteed from 0 C to 125 C junction with the range below 0 C assured by characterisation rather than tested; the I grade is guaranteed over the full minus 40 C to 125 C band; the H grade on this page is guaranteed over minus 40 C to 150 C. Everything else is identical: 3.6 V to 36 V input, 3.5 A output, 95 milliohm switch, 200 kHz to 2.4 MHz, 75 uA burst quiescent, 0.790 V reference. The H code therefore buys exactly one thing, 25 K of junction headroom, and the data sheet is explicit that operating lifetime is derated above 125 C, which tells you how to use it and how not to.

Published values

ParameterValue
Order code, this pageLT3680HMSE#TRPBF, MSOP with exposed pad
H grade guaranteeMinus 40 C to 150 C junction, tested
I grade guaranteeMinus 40 C to 125 C junction, tested
E grade guarantee0 C to 125 C tested, minus 40 C to 125 C by characterisation
Lifetime noteDerated at junction temperatures above 125 C
Input range3.6 V to 36 V
Output current3.5 A maximum, 95 milliohm switch
Burst mode quiescent75 uA at 12 V in to 3.3 V out
Shutdown currentUnder 0.5 uA
Switching frequency200 kHz to 2.4 MHz
Feedback reference0.790 V over the whole grade range

Where the E grade actually stops

The E note says the part is guaranteed to meet performance specifications from 0 C to 125 C and that operation from minus 40 C is assured by characterisation and correlation with process controls. That is a real engineering statement and it is not a guarantee, and the difference matters on a product that ships to a cold climate: a unit that starts at minus 30 C on an E code has no vendor commitment behind the numbers, even though the same die is sold as an I code with that commitment. The H code then adds the top end, 150 C junction, which is a 25 K extension over both of the others.

25 K at 40 to 45 C/W is 0.56 to 0.63 W of extra loss

Turned into power, the extra 25 K is worth 0.56 W at 45 C/W and 0.63 W at 40 C/W, which is the class of thermal resistance the ten pin packages in this family sit on. That is the whole benefit: at a given ambient the H part can carry about half a watt more dissipation before it hits its ceiling. It is a useful half watt on a board where the regulator runs at 1.16 W peak conduction and the enclosure is sealed, and it is not a licence to run at 150 C continuously, because the same paragraph that grants the 150 C limit says lifetime is derated above 125 C. The H code is for excursions, hot starts and worst case ambient days, not for a steady state operating point.

Where a cabinet has no airflow and the housekeeping rail is the hottest thing in it, the grade and the copper are the only two levers. Where a second source is being compared against this order code, the power management cross reference sets out the family; where the concern is that the H code is the one with the long lead time, lead time options is where we check stock against a build date, and the obsolete part hub covers the case where a code is withdrawn while the product is still shipping.

Two questions buyers ask

Can an I grade part run at 140 C junction? No. The I guarantee ends at 125 C and there is no characterised behaviour above it, so a board that reaches 140 C on an I code is outside its specification even though the H code in the same footprint would be inside its own. If the thermal calculation lands above 125 C, the order code has to change or the dissipation has to come down.

Does the H code need different external parts? No. Same inductor, same output capacitor, same feedback divider, same footprint. The only differences are the price, the availability and the marking on the reel, which is worth knowing when a build is split between two grades because the H reel then has to be tracked separately.