LT3650EMSE-8.4#TRPBF

Brand: Analog Devices
Analog Devices LT3650EMSE-8.4#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3650EMSE-8.4#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3650EMSE-8.4#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3650EMSE-8.4#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3650EMSE-8.4#TRPBF: 43 C/W in a 12 Pin MSOP and the 2.5 W of Loss at Full Charge Current

The LT3650EMSE-8.4 is the same 2-cell charger die as the DFN version, in a 12 pin MSOP with an exposed pad. Electrical behaviour is identical: 9 V to 32 V input, 11.5 V start-up, 8.4 V float at 0.5 percent, charge current up to 2 A set by a 100 mV sense threshold, 1 MHz fixed frequency, C/10 or timer termination, 85 uA standby once charging stops. What changes is the package, and the package is where this part gets interesting, because the data sheet lists the same thermal numbers for both bodies: 43 C/W junction to ambient and 3 C/W junction to case, with a 125 C junction ceiling. The package choice is therefore about footprint, inspection and rework, and not about getting more power out of the die.

Published values

ParameterValue
Package12 pin MSOP with exposed pad, pin 13 is GND
Junction to ambient43 C/W
Junction to case3 C/W
Maximum junction125 C
Loss at 2 A charge, typical curve2.4 W to 2.5 W
Output at 8.4 V and 2 A16.8 W
Efficiency at that pointAbout 87 percent
Input current at 12 V in1.61 A
Input current at 24 V in0.80 A
Input current at 32 V in0.60 A
Input range9 V to 32 V, 11.5 V start-up
Float voltage8.4 V plus or minus 0.05 V at 25 C
Charge current accuracy5 percent
Standby after termination85 uA

2.5 W through 43 C/W is 107.5 K, which the part cannot afford at room temperature

The vendor curve for the typical application shows 2.4 W to 2.5 W of loss while the charger holds 2 A, which through 43 C/W is a 107.5 K rise. Add a 25 C bench ambient and the junction is at 132.5 C, already past the 125 C ceiling. Turned the other way, the loss the package can carry is the junction headroom divided by 43: 2.33 W at a 25 C ambient, 1.98 W at 40 C, 1.51 W at 60 C. So 2 A from a 12 V source is a bench number, not a sealed enclosure number. The honest way to use the figure is to pick the charge current so that the loss fits the worst case ambient of the product, and the vendor curve shows the loss falling to 1.6 W, 0.6 W and 0.3 W as the current tapers through 1.5 A, 0.7 A and 0.3 A, which is also where a CC/CV charger spends most of its time.

Where the loss comes from, and why a 12 V adapter is the worst case

At 8.4 V and 2 A the pack takes 16.8 W, so 2.5 W of loss is about 87 percent efficiency. From a 12 V source that is 1.61 A drawn from the adapter, from 24 V it is 0.80 A and from 32 V it is 0.60 A. The input current falls with the input voltage but the switching loss does not: the switch carries the same 2 A at a lower duty cycle, so conduction loss falls and switching loss stays, and the total settles around the same place. The number that surprises people is the 1.61 A at 12 V: a 12 V 2 A adapter is not enough headroom for a 2 A charge because the charger itself keeps 2.5 W, and a 12 V 1.5 A adapter will current limit before the pack reaches full current.

Boards that carry this charger usually also carry the pack connector, the NTC and the status LEDs, and where the whole list ships together one stop BOM sourcing is how we keep it on one shipment. Interchange against the single cell members of the same family is a float voltage question rather than a pin question, which is what the power management cross reference sets out, and where a build is waiting on the exact order code, lead time options lists what is on the shelf.

Two questions buyers ask

Can the MSOP version run 2 A continuously? It can run 2 A for as long as the junction stays under 125 C, and at 43 C/W with 2.5 W of loss that means an ambient below 17.5 C. In a sealed box at 50 C the same package carries about 1.7 W, which lands nearer 1.5 A of charge current. The DFN version has the same 43 C/W, so moving to the smaller body does not buy thermal headroom.

Does the exposed pad have to be soldered? Yes. The pad is pin 13 and it is the ground return as well as the thermal path. A pad left unsoldered gives a charger that works on the bench and drops out of regulation when the pack is empty and the current is highest, which is the most expensive way to find out.