LT3065EMSE#TRPBF
Product Specifications
LT3065EMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3065EMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3065EMSE#TRPBF: the standard grade 500 mA regulator and what its 0 C floor means
The LT3065EMSE#TRPBF is the E grade of the LT3065 in the 12-lead MSOP on tape and reel. The electrical table is identical to the rest of the family: 1.6 V to 45 V input, 500 mA output, 0.6 V to 40 V adjustable, 300 mV of dropout at full load, 25 uV RMS of noise with a 10 nF bypass capacitor, a current limit set by one resistor to plus or minus 10 percent, and a PWRGD flag. The E suffix is the temperature qualification, and it is the only thing that separates this code from the I grade on the same body.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 1.6 V to 45 V, 2.2 V maximum at 500 mA |
| Output voltage | 0.6 V to 40 V adjustable, fixed options 1.2 V to 5 V |
| Output current | 500 mA |
| Dropout voltage | 110 mV at 10 mA, 220 mV at 100 mA, 300 mV at 500 mA |
| GND pin current | 55 uA no load, 1.8 mA at 100 mA, 11 mA at 500 mA |
| Output noise | 90 uV RMS bare, 25 uV RMS with 10 nF on REF/BYP |
| Ripple rejection | 70 dB minimum at 120 Hz, 85 dB typical |
| Shutdown current | 0.2 uA typical, 1 uA maximum at 45 V |
| Reverse output current | 10 uA maximum |
| Thermal resistance | 28 C/W junction to ambient, 6 C/W to case |
| Grade and package | 12-lead MSOP, tested at 25 C, 0 C to 125 C guaranteed |
Reading the E grade correctly
This is where most of the confusion in this family sits. The E grade is tested at 25 C, its performance from 0 C to 125 C is guaranteed, and its behaviour from minus 40 C to 0 C is assured by characterization and statistical correlation rather than by test. In a heated indoor product that is a non-issue. In a product that is stored in an unheated warehouse, shipped in a container through a winter and then switched on for the first time at the customer site, it is the difference between a documented specification and an assumption. The practical test is simple: if the drawing says minus 40 C, the E grade is the wrong line item no matter how the bench data looks, and the I grade on the same body is the answer.
Where the standard grade is the right answer
Plenty of boards never see freezing. Bench instruments, indoor lighting controllers, point of sale terminals, lab equipment and any product with a heater or a self warming enclosure can take the E grade and never touch the cold end of its window. On those programs the E code is the cheapest way to buy the 45 V input range, the 500 mA output and the 25 uV RMS noise figure, because the die is the same and only the test coverage changes. The savings are real but modest, so the decision should be made on the specification and the paperwork rather than on price alone. A file that has been running the I grade for years and switches to E to save cents has taken on a documentation change for a line item that was never the cost driver.
PWRGD, bypass and the divider
The functional pins behave the same on every grade. PWRGD is open drain, trips at 90 percent of nominal with a 86 to 94 percent window and 1.6 percent of hysteresis, and pulls down to 0.07 V at 50 uA while leaking 0.01 uA at 45 V. A capacitor on REF/BYP sets both the noise and the soft start: 10 nF brings the noise to 25 uV RMS at a 0.6 V output, and a larger value slows the ramp into an inrush sensitive load. The divider on ADJ sets the output with the lower resistor capped at 62 kOhm, which keeps 10 uA in the divider and holds the 16 nA of ADJ bias current to a small error term. The output capacitor is 3.3 uF of ceramic minimum, chosen for stability rather than for ripple.
The fault behaviour
Three protections are worth knowing before a fault test. The input is protected against reverse battery, quoted as 300 uA of leakage at minus 45 V, so a reversed connector does not destroy the part. The output is protected against reverse current, quoted at 10 uA maximum with the input grounded, so a rail that is back fed by a charged load does not pull current through the regulator. The current limit folds back with input to output differential, so a shorted output at 40 V input does not sit at the full 520 mA in the pass element, and the thermal limit takes over if the die still heats. A fault test that assumes a constant current limit at high input voltage will over predict the stress and under predict the recovery time.
Supply position
The E grade is the code that distributors hold deepest, since it is the catalogue default, and it is the first to come back when a shortage clears. Files that carry both E and I codes on the same rail are best kept on one cross reference so the grade is visible at the line item rather than in a drawing note, which is what the power management cross reference shows. Mixed BOMs are consolidated on the one stop BOM sourcing page, and lead time movement on the MSOP body is tracked on the lead time page.