HMC920LP5E
Product Specifications
HMC920LP5E
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The HMC920LP5E from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HMC920LP5E: An Active Bias Controller Replaces the Gate Divider on a Class-A Amplifier
The HMC920LP5E is an active bias controller. It does not amplify, mix or switch anything. It produces a regulated drain voltage between 3 V and 15 V from a single positive supply of 5 V to 16.5 V, and it moves the gate voltage of an external amplifier until the drain current reaches the set point, up to 500 mA. What it removes from a Class A stage is the first power up ritual: a technician with a bench supply, a current meter and a trimmer, setting the gate by hand on every unit, and then the same setting drifting away with temperature and with age. The loop closes that job in hardware and leaves a single resistor to set the current.
What the two loops actually control
The drain voltage is regulated directly. The drain current is regulated indirectly, by adjusting the gate, which is the only handle a field effect transistor offers. Because the negative rail for the gate is generated inside the part, a depletion mode device can be pinched off without a second supply on the board. That is the specific case where a resistor divider from the positive rail cannot work: the gate has to go below ground, and nothing on a single positive rail can take it there.
| Item | Value | What it decides on the board |
|---|---|---|
| Supply voltage | 5 V to 16.5 V | One positive rail; the gate rail is generated internally |
| Drain voltage | 3 V to 15 V, adjustable | Covers stages that run below the supply, not a 28 V device |
| Drain current | 0 to 500 mA | Quiescent current of a driver or a small power stage |
| Alarms | Over current, under current, low supply | Three separate flags, so a fault can be told apart at the panel |
| Sequencing | Enable input and trigger out | Several controllers can be chained in order at power up and down |
Where the 15 V and 500 mA ceilings bite
At 15 V and 500 mA the external device dissipates 7.5 W. The controller is not the hot part in that picture, the amplifier is, so the thermal work belongs to the amplifier flange or the exposed pad under it. The other ceiling is the supply: 16.5 V is the top of the range, which rules out a 28 V LDMOS stage. A board that needs a bias controller above 15 V of drain has to look elsewhere, and the usual answer is a discrete current sense amplifier plus a charge pump.
Why the alarm and sequencing pins are worth paying for
A stage that fails usually fails quietly: the gain drops, the current climbs, and nothing on the front panel says so until the customer reports a dead channel. The over current and under current flags each drive a comparator, and the trigger out lets stage two come up only after stage one reports good bias. In a multi stage chain that order matters, because a driver biased into a load that is not yet powered can be damaged by the reflected signal.
Replacing a discontinued bias controller
When a board is being reworked around an obsolete bias part, the questions in order are the drain voltage ceiling, the current range and the polarity of the gate drive, not the package. A controller that tops out at 12 V will not run a stage that was set to 13.5 V, and a controller without an internal negative generator needs a rail the board may not have. The RF component sourcing page covers the bias and control family, the defense grade components page covers the temperature and screening grades, and incoming lots are checked against the incoming inspection plan.