Current to Voltage Modules for Photodiode Front Ends
Product Specifications
Product Overview
A photodiode answers light with current, and almost every converter behind it wants a voltage. The part that sits between the two decides how much of the signal survives. A module bought on gain alone will usually disappoint, because gain and bandwidth are traded against each other inside the same amplifier, and the noise floor moves with the source capacitance on the input.
The trade is visible in the numbers. At 1,000 V/A a fast module still passes 200 MHz, which suits a picosecond pulse from an avalanche photodiode. At 10^11 V/A the same family stops at about 1 kHz, which suits a steady photocurrent from a photomultiplier in a scanning microscope. Between those two ends the useful question is not which module has the most gain, but which gain still keeps the bandwidth the measurement needs.
Placement matters as much as the part. The unamplified current is the most fragile signal in the chain, so the module belongs within a few centimetres of the detector, with the shortest possible input lead. Every extra centimetre of cable adds capacitance at the input, which reduces bandwidth and raises the noise seen by the amplifier. This is why the compact modules in this family are built as small metal cases with a screw pattern that mounts straight onto the detector housing.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Transimpedance gain | 100 V/A to 10^13 V/A across the family | TIA60 is fixed at 30,200 V/A typical |
| Bandwidth at 3 dB | DC to 200 MHz at the lowest gain, 1.1 kHz at 10^11 V/A | Bandwidth falls as gain rises inside one module |
| Input current noise | 4.8 pA per root Hz at 1 MHz on TIA60, 4.3 fA per root Hz at 10^11 V/A | Quoted with a 4 pF source capacitance on TIA60 |
| Linear input range | Plus or minus 50 uA at 0 V bias on TIA60 | Maximum input plus or minus 500 uA |
| Output swing | Plus or minus 1.5 V into 50 ohm on TIA60, plus or minus 10 V on the bench units | Output current 30 mA on DLPCA-200 |
| Input coupling | DC, or AC with the low frequency cut switched in | 10 Hz low pass available on DLPCA-200 |
| Bias on the input | Plus or minus 10 V at 22 mA on the input shield | Speeds up an external photodiode without a second supply |
| Gain accuracy | Plus or minus 1 per cent | Gain settling under 80 ms on DHPCA-100 |
| Supply | 9 to 15 V at 65 mA typical on TIA60 | Bench units take plus or minus 15 V at about 200 mA |
| Case | 95.9 x 55.9 x 26.8 mm, 100 g on TIA60 | SMA input, BNC output, 4 pin power socket |
| Ambient | 5 to 55 C operating, minus 40 to 55 C storage | TIA60 quoted figure |
| Filters | 10 Hz on DLPCA-200, 1 MHz and 10 MHz on DHPCA-100 | Switchable, for trimming wideband noise |
Included Models and Order Codes
The table is ordered by bandwidth, fastest first, because that is the order in which a measurement narrows the choice. A fixed gain module sits at the top for photomultiplier work, the middle rows cover variable gain in the megahertz range, and the last rows are the femtoamp converters where a 2 Hz bandwidth is the point rather than a limit.
| Part Number | Gain (V/A) | Bandwidth | Input Noise | Output | Package |
|---|---|---|---|---|---|
| TIA60 | 30,200 typical (29,000 to 32,000) | DC to 60 MHz | 4.8 pA per root Hz at 1 MHz | Plus or minus 1.5 V into 50 ohm | 95.9 x 55.9 x 26.8 mm, SMA in, BNC out |
| DHPCA-100 | 10^2 to 10^8 | DC to 200 MHz at 10^3 V/A | 1.8 ns rise time at 10^3 V/A | Plus or minus 10 V, 30 mA | Bench case, BNC in and out |
| DLPCA-200 | 10^3 to 10^11 | DC to 500 kHz at 10^3 V/A | 4.3 fA per root Hz at 10^11 V/A | Plus or minus 10 V, 30 mA | Bench case, BNC in and out |
| LCA-4K-1G | 10^9 | 4 kHz | 6.5 fA per root Hz | 100 us rise time | Module with BNC output |
| LCA-200-10G | 10^10 | 200 Hz | 1.5 fA per root Hz | 2 ms rise time | Module with BNC output |
| LCA-2-10T | 10^12 and 10^13 | 2 Hz | 0.18 fA per root Hz | 200 ms rise time | Module with BNC output |
| DDPCA-300 | 10^4 to 10^13 | 400 Hz at 10^4 down to 1 Hz at 10^13 | 0.4 fA peak to peak at the 0.1 Hz filter | Plus or minus 10 V | Bench case, BNC in and out |
Key Features
Gain quoted with its bandwidth – 10^8 V/A still reaches 220 kHz on the DHPCA-100, while 10^3 V/A reaches 200 MHz, so the pair is read together
Fixed gain for photomultiplier work – the TIA60 holds 30,200 V/A with a 5.5 ns rise time and mounts on an H7422 housing
Femtoamp range on the same bench – the LCA-2-10T converts 10^13 V/A with a 200 ms rise, for steady photocurrent rather than pulses
Bias supplied at the input – plus or minus 10 V at 22 mA on the input shield, which speeds up a photodiode without a second supply
Filters against wideband noise – 10 Hz on the DLPCA-200 and 1 MHz or 10 MHz on the DHPCA-100, switched at the front panel
Chip level alternative – the same conversion as a transimpedance amplifier die when the board has to carry the circuit itself
Applications
These modules are ordered with the detector, because the gain and the noise floor have to be fixed before the optics are aligned against a known signal.
Photomultiplier and photon counting – a fixed gain module bolted to the detector housing, driving a counter through a 50 ohm cable
Spectrophotometer detector boards – a variable gain module behind a photodiode array, set once for the method and locked
Laser scanning and ranging – a fast module at the receiving diode, where 1.8 ns rise time sets the distance resolution
Detector boards that carry these modules are assembled as SUPERB PCB and SUPERB PCBA work when the instrument moves from the bench to production.
Sourcing and Cross-Reference
The first number to settle is the current the detector actually delivers. A photodiode in a spectrophotometer may run from a nanoamp to a few microamps, which a 10^6 to 10^8 V/A module covers. An avalanche photodiode in a ranging receiver can deliver milliamps in a short pulse, and a high gain module will simply saturate on it. The maximum input current on the data sheet is the figure that decides this, not the gain.
The second number is source capacitance. Every module in this family is characterised with a small capacitance at the input, and bandwidth falls when the real detector and its cable add more. A photodiode with 4 pF and a 30 cm cable can easily present 60 pF, which costs bandwidth and adds noise. Short leads and a module mounted at the detector are worth more than one gain step.
Where the board has to carry the circuit rather than a module, the same function is available as a transimpedance amplifier chip, and we list those separately with their own feedback network values. Both routes are quoted with the detector in mind, which is why we ask for the photodiode part number and the expected photocurrent before naming a gain.
Kits that pair a module with its detector housing are packed through SUPERB Assembly, with the cable and the mounting screws in the same box.
Q: Can you supply a fixed gain module that matches a photodiode already fitted to our instrument, including the bias supply?
A: Yes. SUPERB Tech quotes the module, the bias supply and the input connector together, and states the maximum input current before the order is placed.
Why Choose SUPERB for Current to Voltage Modules
- Gain and bandwidth side by side: every row states both, so the module is not chosen on gain alone
- Noise floor quoted: current noise in pA or fA per root Hz, at a stated frequency and source capacitance
- Bias and filters included: the input bias and the low pass filter are on the module, not on a second board
- Module or chip: the same conversion quoted as a bench module or as a die for the board, with the detector part number on the line
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Transimpedance Amplifier Chips for Optical Receivers, PIN and Avalanche Photodiodes, Photodiode Arrays and Detector Modules, Photomultiplier Tubes and PMT Housings, Optical Power Monitor and Log Amplifier Chips, Obsolete Part Cross Reference.