ADXL103CE-REEL
Product Specifications
ADXL103CE-REEL
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADXL103CE-REEL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADXL103CE-REEL: 1 mg at 60 Hz is 0.057 degrees of tilt, and 110 ug per root hertz gets there
The ADXL103CE-REEL is an Analog Devices single axis MEMS accelerometer with a signal conditioned analog output in a 5 mm by 5 mm by 2 mm 8-terminal ceramic LCC package. The family covers plus or minus 1.7 g, plus or minus 5 g and plus or minus 18 g, the output is a signal conditioned analog voltage, and the bandwidth is set from 0.5 Hz to 2.5 kHz by a single capacitor. Noise density is 110 ug per root hertz typical, which the vendor presents as 1 mg of resolution at 60 Hz and 0.06 degrees of inclination in a narrow band. Supply current is 700 uA at 5 V, the part is specified from -40 C to +125 C, axes are aligned to within 0.1 degree typical, and it survives 3500 g of shock. It is on the analog and mixed-signal IC line card.
The bandwidth capacitor is a resolution specification, not a decoupling part
One hundred and ten micrograms per root hertz over a 60 Hz band is 0.852 mg rms, which is where the 1 mg headline comes from. Over a 500 Hz band the same density gives 2.46 mg, and over 2.5 kHz it is 5.5 mg. Since 1 mg of horizontal acceleration is 0.0573 degrees of tilt near level, the usable tilt resolution moves from about 0.05 degrees to 0.31 degrees purely by the choice of two capacitors. A customer who quotes 1 mg without quoting the band is quoting a part he has not finished specifying.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Axis and range | single axis, plus or minus 1.7 g, 5 g or 18 g | range fixed by order code |
| Noise density | 110 ug per root hertz | 0.852 mg over 60 Hz, 5.5 mg over 2.5 kHz |
| Resolution claim | 1 mg at 60 Hz | 0.0573 degrees of tilt |
| Resolution against range | 1 mg of 1.7 g | 0.0588 percent, 10.7 bits of span |
| Bandwidth | 0.5 Hz to 2.5 kHz, one capacitor | a 5000 to 1 range from passive parts |
| Supply current | 700 uA at 5 V | 3.5 mW, usable from a battery instrument |
| Alignment | axes within 0.1 degree typical | a mounting error larger than the resolution |
| Shock | 3500 g survival | unpowered handling is not the limit |
| Temperature | -40 C to +125 C | the same package rating as the automotive parts |
Ten and a half bits is the honest resolution of a 1.7 g part
If 1 mg is the smallest acceleration that can be resolved, then the usable span against the 1.7 g range is 0.0588 percent, or 10.7 bits. That is a perfectly usable number for a platform leveller and a poor one for a vibration analyser, which is why the same family is offered at 5 g and 18 g: a shock or vibration measurement needs the range and gives up resolution for it. Choosing the 1.7 g part to measure a 10 g shock guarantees a clipped waveform, and choosing the 18 g part to measure tilt costs a factor of ten in resolution.
Selection notes
- A single capacitor per axis sets the bandwidth, so the same order code serves a 0.5 Hz tilt loop and a 1 kHz vibration channel.
- The analog output is sampled by whatever converter the board already has, which is often cheaper than adding a digital accelerometer and its bus.
- Two axes are available in the same package as the ADXL203, which removes the alignment error between two separate parts.
- The 3500 g shock rating is a survival figure and not a measurement range, so an abuse event detector still needs the 18 g version.
Questions buyers ask
Is the output digital? No, it is an analog voltage, and the resolution of the measurement is set by the converter behind it as much as by the sensor's noise.
Does the bandwidth capacitor change the sensitivity? It changes the noise band and therefore the resolution, while the sensitivity at low frequency stays as specified.
Sensor front ends are compared on pin to pin cross reference, and the parts grouped for patient handling and diagnostic equipment are under medical device components.
Request Quote — In Stock, 100% New & Original, Full Warranty