ADUM1441ARQZ-RL7
Product Specifications
ADUM1441ARQZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADUM1441ARQZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADUM1441ARQZ-RL7: 22.4 uA for four isolated channels, or 196 mAh over a year
The ADUM1441ARQZ-RL7 is an Analog Devices micropower quad-channel digital isolator with three channels in one direction and one in the other, default high, in a 16-lead QSOP. At 3.3 V the quiescent current is 5.6 uA per channel with the internal refresh enabled and 0.3 uA per channel with it disabled, and the dynamic current is 148 uA per Mbps per channel. At 2.5 V the same figures are 3.1 uA, 0.1 uA and 117 uA per Mbps. The data rate is up to 2 Mbps, operation is specified to 125 C, and common mode transient immunity is above 25 kV per microsecond. Isolation is 2500 V rms for one minute with a 565 V peak working voltage in the QSOP, and the 20-lead SSOP version raises that to 3750 V rms and 645 V peak. Intrinsic safety approvals cover both bodies. It is on the analog and mixed-signal IC line card.
Twenty two microamps is a battery life figure, not a data sheet curiosity
Four channels at 5.6 uA is 22.4 uA, which at 3.3 V is 74 uW and 196 mAh over a year. With the refresh disabled the same four channels are 1.2 uA and 11 mAh a year. At 1 Mbps the dynamic term dominates: 148 uA per channel, 592 uA for four, which is 2 mW. So the part has two very different operating points, one for a sensor that reports a few times an hour and one for a continuous link, and the quiescent figure only describes the first.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Channels | 4, three forward and one reverse, default high | a bidirectional link with a mostly outbound payload |
| Quiescent current | 5.6 uA per channel, 0.3 uA refresh disabled | 22.4 uA for four, 196 mAh a year, or 11 mAh |
| Dynamic current | 148 uA per Mbps per channel at 3.3 V | 592 uA for four at 1 Mbps, 2 mW |
| Data rate | up to 2 Mbps | 45 times below the 90 Mbps rate of the ADuM1402 |
| Isolation, QSOP | 2500 V rms one minute, 565 V peak working | 3536 V peak withstand |
| Isolation, SSOP | 3750 V rms one minute, 645 V peak working | 5303 V peak withstand, 1.5 times the QSOP |
| Temperature | 125 C | the refresh enabled setting is required above 105 C |
The refresh setting is a temperature decision as well as a current decision
With the internal refresh disabled the part holds its output state with almost no current, but the dc correctness of the link depends on the input changing often enough. The vendor requires the refresh to be enabled above a stated temperature because leakage can move a static input. That is why the two current figures come with a condition rather than a choice: a link that carries a clock or a regularly toggling signal can run with refresh off, and a link that can sit idle for minutes cannot.
Selection notes
- Default high means the output is high when the input side is unpowered, which sets the safe state of an enable line at power up.
- The 2 Mbps rate suits a slow field bus and a sensor interface, not a high speed parallel bus.
- The SSOP body doubles the isolation rating for the same die, so the package choice is a safety decision.
- Intrinsic safety approvals allow the part inside equipment that must remain safe in a hazardous area, which is a certification path rather than a performance one.
Questions buyers ask
Can this replace a 90 Mbps isolator? Only if the link runs at 2 Mbps or less. The pinout and the channel count may match, but the rate does not.
Is the 196 mAh a year figure the whole battery budget? It is the isolator's share. The sensor and the processor usually account for more, and the isolator is chosen to disappear from that budget rather than to dominate it.
Isolators are swapped between bodies more often than between families, and the arithmetic for a lower cost equivalent is on how to reduce component cost with the pinout checks on pin to pin cross reference.
ADUM1441ARQZ-RL7 at 2 Mbps: the dynamic term is 100 times the quiescent one, and the refresh setting decides dc correctness
The quiescent figures of 5.6 uA per channel and 0.3 uA per channel with the refresh disabled are what a standby budget is built on. They are not what the part draws when it is working. The dynamic term is 148 uA per megabit per second per channel, so a single channel at 2 Mbps draws 296 uA, five times its own idle current, and four channels at full rate draw 1.18 mA, which is 53 times the 22.4 uA that the headline figure describes. A budget that uses one number for both states will be wrong by more than an order of magnitude.
Energy per bit is the comparison that survives a change of rate
At 3.3 V the dynamic current of 148 uA per megabit is 488 uW per megabit, which is 0.49 nJ per bit per channel. That figure stays constant across the 0 to 2 Mbps range, so a link that runs at 100 kbps for 90 percent of the time and 2 Mbps for the rest is dominated by the fast bursts rather than by the average. It also makes the part comparable with other isolation technologies on a basis that does not depend on the data rate chosen for the comparison.
Refresh disabled is a dc correctness decision, not only a current one
With the internal refresh disabled, the current falls to 0.3 uA per channel and 1.2 uA for four, 11 mAh over a year. The cost is that the channel no longer corrects for a static input: the receive side holds the last state and a slow or unchanging input is not refreshed. A link that carries a level which changes at least once per refresh interval is fine; a link that carries an enable line held high for hours is not. That is why the 22.4 uA figure is the one quoted for a general purpose link and the 1.2 uA figure belongs to a specific data pattern.
Working voltage against the withstand rating
The published isolation is 2500 V rms for one minute with a 565 V peak working voltage, and the 20-lead SSOP member of the family raises that to 3750 V rms and 645 V peak. The one minute number is a test, and the working voltage is what the part is rated to hold continuously: 565 V peak is 400 V rms, so the continuous capability is 6.25 times lower than the withstand figure. A 400 V bus sits exactly at the working limit and a 480 V bus is outside the part regardless of how the withstand test reads.
| Data rate | Dynamic current per channel | Four channels | Power at 3.3 V | Energy per bit per channel |
|---|---|---|---|---|
| Idle, refresh enabled | 5.6 uA | 22.4 uA | 74 uW | not applicable |
| Idle, refresh disabled | 0.3 uA | 1.2 uA | 4.0 uW | not applicable |
| 100 kbps | 14.8 uA | 59.2 uA | 195 uW | 0.49 nJ |
| 1 Mbps | 148 uA | 592 uA | 1.95 mW | 0.49 nJ |
| 2 Mbps | 296 uA | 1.18 mA | 3.90 mW | 0.49 nJ |
Isolated interface alternatives are on the how to verify a drop in replacement page, patient connected equipment requirements are on medical device components, and the consolidated order route is on one stop BOM sourcing.
Request Quote — In Stock, 100% New & Original, Full Warranty