ADT75BRMZ
Product Specifications
ADT75BRMZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADT75BRMZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADT75BRMZ: the B grade ADT75, and what plus or minus 1 C actually covers
The ADT75BRMZ is the B grade of the ADT75 temperature sensor in the 8-lead MSOP. It is the grade that carries the plus or minus 1 C figure printed across the family literature, and the window that figure applies to is 0 C to +70 C, not the full -55 C to +125 C operating range. That distinction decides whether the part can be used at all in an enclosure that sees sub zero mornings or a warm cabinet.
Published values
| Parameter | Value |
|---|---|
| Converter | 12-bit, 0.0625 C per code |
| Accuracy, B grade | plus or minus 1 C from 0 C to +70 C |
| Operating range | the device is specified for operation from -55 C to +125 C |
| Supply range | 2.7 V to 5.5 V |
| Conversion time | 60 ms, new result every 100 ms |
| Shutdown current | 3 uA typical |
| Power at 3.3 V | 79 uW typical |
| Bus | SMBus and I2C, eight addresses through three pins |
| Alert | OS/ALERT open drain, TOS and THYST setpoints, fault queue |
| Package | 8-lead MSOP, option RM-8, marking T5B |
The plus or minus 1 C window is 70 degrees wide
Between 0 C and +70 C the B grade holds plus or minus 1 C. Outside that window the datasheet does not promise the same number, and the A grade is the code that carries plus or minus 2 C from -25 C to +100 C and plus or minus 3 C beyond it. A unit that is stored cold and then powered in a warm room passes through both windows in a single working day.
So the choice between the two grades is made from the ambient range of the enclosure, not from the price of the reel. Where the range is genuinely 0 C to +70 C, this grade is the tighter of the two by a factor of two.
What the part reports and when
One code is 0.0625 C, which is far finer than either grade window, so the reading looks precise even when the absolute accuracy is plus or minus 1 C. Drift over ten years at 55 C is 0.08 C and hysteresis 0.03 C, both quoted for the device rather than for the grade.
Conversion takes 60 ms and the register updates every 100 ms. One shot mode converts on demand, which is how a portable instrument keeps the average current near the shutdown figure instead of drawing the 79 uW running power continuously.
Alert behaviour in a real cabinet
TOS sets the trip point and THYST sets the release, and the fault queue decides how many consecutive conversions must exceed the limit before OS/ALERT moves. With a 12-bit part and a 1 C grade, a queue of two or three conversions is normal, because the resolution is fine enough to see noise on the die.
All eight addresses can sit on one bus with the alert lines wired together, and the host polls each address to find which device tripped. That is cheaper than eight interrupt inputs and costs a few hundred microseconds of bus time.
Where the grade is the deciding factor
Fan control, thermal shutdown of a power supply and enclosure monitoring inside a temperature controlled room are the natural fits. Anything that has to survive a cold store, a winter shipment or an outdoor cabinet belongs on the A grade.
Sourcing notes for this family: medical device components holds the cross references, BOM shortage recovery is the pre substitution check, and vendor consolidation is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask
Is the B grade a better part than the A grade? It is tighter over a narrower window: plus or minus 1 C from 0 C to +70 C against plus or minus 2 C from -25 C to +100 C. Neither is better in general; the ambient range decides.
What happens below 0 C with this grade? The device still converts and reports, but the plus or minus 1 C figure does not apply. A board that needs a guaranteed number below freezing moves to the A grade.