ADM2486BRWZ-REEL
Product Specifications
ADM2486BRWZ-REEL
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADM2486BRWZ-REEL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADM2486BRWZ-REEL: 20 Mbps across an isolation barrier with 560 V of working voltage
The ADM2486BRWZ-REEL is an Analog Devices half duplex RS-485 transceiver with a galvanically isolated bus side, combining a three channel isolator, a three state differential driver and a differential receiver in a 16-lead wide body SOIC. It runs to 20 Mbps, complies with ANSI EIA/TIA-485-A and ISO 8482 and is PROFIBUS compliant, supports 50 nodes on the bus, and provides an isolated driver enable status output so the controller can see the bus state without a second isolator. The logic side runs from 5 V or 3 V while the bus side needs an isolated 5 V supply. Common mode transient immunity is above 25 kV per microsecond, the receiver has a fail safe output for an open circuit, thermal shutdown protects against contention, the withstand rating is 2500 V rms for one minute with a 560 V peak working voltage, and the part is specified from -40 C to +85 C. It is on the analog and mixed-signal IC line card.
Fifty nanosecond bits and a hundred metres of cable do not go together
At 20 Mbps a bit is 50 ns. A twisted pair propagates at roughly 5 ns per metre, so 100 m of cable is 500 ns one way, which is ten bit periods before the far end has even started to answer. That is the arithmetic behind the rule that a fast isolated transceiver belongs on a short drop and a long field bus belongs at 500 kbps or lower. The isolator does not change the cable; what it changes is that the ground potential between the two ends can differ by hundreds of volts without a current flowing through the cable shield.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Data rate | 20 Mbps, half duplex | 50 ns per bit |
| Cable delay | about 5 ns per metre | 100 m is 500 ns, ten bit periods |
| Nodes | 50 on the bus | a unit load per node, not a fractional one |
| Common mode immunity | above 25 kV per microsecond | 25 mV of disturbance per nanosecond of edge |
| Withstand | 2500 V rms for one minute | 3536 V peak, a test figure |
| Working voltage | 560 V peak | 396 V rms continuous, 6.3 times below the test |
| Logic side supply | 5 V or 3 V | a 3.3 V controller connects directly |
| Bus side supply | isolated 5 V | a separate isolated converter is required |
| Temperature | -40 C to +85 C | the industrial window, not the extended one |
The isolated driver enable output removes a round trip through the barrier
A half duplex bus has to turn the driver around between a request and a response, and the controller needs to know when the driver is actually enabled. Bringing that status back through a second isolator channel costs a part and adds a delay that depends on the second device's propagation time. Here the status comes back inside the same package, so the turnaround timing is set by one data sheet rather than by two, which is what makes 20 Mbps usable on a multi drop segment at all.
Selection notes
- The bus side needs its own isolated 5 V rail, which is the difference between this part and the members of the family with an integrated converter.
- Fifty nodes at a unit load each is a bus with 50 terminations to account for, so the bias and termination resistors are chosen for the node count rather than for a pair of endpoints.
- The fail safe receiver reports a defined level on an open or idle bus, which is what stops a disconnected node from generating framing errors.
- Thermal shutdown protects the driver during contention, but it is a protection and not a mode of operation.
Questions buyers ask
Does it need an isolated power supply? Yes on the bus side. A part with the converter inside removes that requirement at the cost of output power and emissions, and the choice between the two is made on the load current the bus side needs.
Is 20 Mbps realistic on a field bus? Only on a short segment. At 100 m of cable the propagation delay alone consumes ten bit periods, so the rate has to come down with the length.
Isolated interface parts are compared on pin to pin cross reference, and the sourcing options for a build that needs a second source are on BOM shortage recovery.
Request Quote — In Stock, 100% New & Original, Full Warranty