ADG5204BRUZ-RL7
Product Specifications
ADG5204BRUZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADG5204BRUZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADG5204BRUZ-RL7: 0.6 pC of charge injection and a trench that stops latch-up at 48 V
The ADG5204BRUZ-RL7 is an Analog Devices four-channel analog multiplexer in a 16-lead TSSOP, built on a trench process that puts a dielectric barrier between the N and P channel transistors so the part cannot latch up even with the supplies exceeded. Off source capacitance is 3 pF, off drain capacitance is 26 pF, charge injection is 0.6 pC, and leakage is 0.4 nA maximum at 85 C. Supply range is plus or minus 9 V to plus or minus 22 V dual, or 9 V to 40 V single, with 48 V absolute maximum, and the part is fully specified at plus or minus 15 V, plus or minus 20 V, 12 V and 36 V. The three address lines A0, A1 and EN select one of four inputs to a common drain, all switches are bidirectional, and break-before-make action prevents two channels from shorting during a change. It is on the analog and mixed-signal IC line card.
Charge injection is the number that decides the sample and hold error
0.6 pC dumped into a 10 pF hold capacitor is a 60 mV step, into 100 pF it is 6 mV, and into 1000 pF it is 0.6 mV. A 16-bit converter with a 5 V span has a code size of 76 uV, so a 10 pF hold capacitor sees a glitch of 787 codes and even a 1000 pF capacitor sees 8 codes. That is why a multiplexer in front of a precision converter is followed by a buffer whose settling is specified, and why the charge injection figure matters more than the on resistance in that application.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Channels | 4 to 1, bidirectional | break-before-make on every change |
| Charge injection | 0.6 pC | 60 mV into 10 pF, 6 mV into 100 pF |
| Off capacitance | 3 pF source, 26 pF drain | 53 kohm and 6.1 kohm reactance at 1 MHz |
| Leakage | 0.4 nA maximum at 85 C | 0.4 mV into a 1 Mohm source |
| Supplies | plus or minus 9 V to 22 V, or 9 V to 40 V single | 44 V signal span on a dual rail |
| Absolute maximum | 48 V | 8 V above a 40 V single supply, which is the fault headroom |
| Package | 16-lead TSSOP | same footprint family as the rest of the ADG52xx line |
Latch-up immunity is a field reliability claim, not a laboratory one
A conventional CMOS switch can be driven into a parasitic thyristor state when an input exceeds its supply, and the state persists until the power is removed. In an instrument connected to a transducer on a long cable, that event is caused by the cable picking up a transient while the instrument is off. The dielectric trench removes the four layer path, so the part survives the event and the equipment does not need a service call. That is why this family is used in avionics and process control where the connector is accessible.
Selection notes
- The 26 pF off drain capacitance is common to all channels, so an off channel loads the common node through it at high frequency; 6.1 kohm at 1 MHz is not negligible beside a high impedance buffer.
- Fully specified at four supply combinations means the data sheet figures apply at 12 V and 36 V single supply, not only at plus or minus 15 V.
- The EN pin disables all channels and puts the drain in a high impedance state, which allows several multiplexers to share one bus.
- Charge injection is specified as a single figure, and its sign and magnitude vary with supply and signal level, so the residual error is trimmed in the buffer rather than predicted from the data sheet alone.
Questions buyers ask
Is this a drop-in for the ADG5204 without the trench? The pinout follows the same family pin order, and the electrical difference is the fault behaviour. A socket built for a standard CMOS switch will work, and the reason to specify this part is the overvoltage case.
Does 40 V single supply mean a 40 V signal can be switched? Yes, the analog signal range extends to the supplies, and the 48 V absolute maximum gives 8 V of transient headroom.
Multiplexer swaps are checked on pin to pin cross reference, and the parts held for patient connected equipment are grouped under medical device components.
Request Quote — In Stock, 100% New & Original, Full Warranty