Analog Devices ADCMP671-1YUJZ-RL7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADCMP671-1YUJZ-RL7 — Analog & Mixed-Signal ICs | Superb Automation

ADCMP671-1YUJZ-RL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADCMP671-1YUJZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADCMP671-1YUJZ-RL7: One Window Monitor for N Rails and N Plus One Processor I/O

The ADCMP671-1YUJZ-RL7 is a supply window monitor from Analog Devices in a 6-lead TSOT package 1 mm high. It contains two low power comparators and a 400 mV reference accurate to plus or minus 0.275 percent at 3.3 V and 25 C, operates from 1.7 V to 5.5 V, and draws 8.55 uA maximum. Input bias current is plus or minus 2.5 nA maximum, the input range includes ground, internal hysteresis is 9.2 mV typical, and both outputs are open drain, guaranteed to sink more than 5 mA over temperature. The PWRGD output reports that the rail is inside the window and the OV output reports an overvoltage, which is how N rails can be watched with N plus one processor input.

The thresholds are set by two resistors, so the divider is the accuracy

Because the reference is 400 mV, a 3.3 V rail needs a divider ratio of 8.25. The 0.275 percent reference tolerance is 1.1 mV at the comparison node, and that becomes 9.1 mV when referred back to the 3.3 V rail. The 9.2 mV of internal hysteresis becomes 76 mV at the rail, which is the band a rail has to leave before the output changes state again: it is what stops a supply sitting exactly at the trip point from chattering into the processor, and it is also why a monitor with 76 mV of hysteresis cannot be used to detect a 50 mV margin.

The divider current, not the part, sets the rail budget

A 100 k top resistor and a 13.8 k bottom resistor draw 29 uA from a 3.3 V rail, which is more than three times the 8.55 uA the monitor itself uses. The 2.5 nA of bias current through the 12.1 k Thevenin impedance of that pair adds 30 uV at the node, or 0.25 mV at the rail, so a stiff divider is also the accurate one. Raising the pair to 1 Mohm cuts the divider current to 3.3 uA but multiplies the bias error by ten, to about 2.5 mV at the rail, which is where the choice stops being free. The 8.55 uA part current is low in absolute terms but not coin cell low: a year of it is 75 mAh, about a third of a CR2032, so this monitor belongs on a mains or Li-ion rail rather than a ten year coin cell product.

Why the output pair saves pins

Every PWRGD output can be wired together into one open drain node, because each one only pulls low when its own rail is out of window. All the OV outputs need to be separate if the processor has to know which rail went high, which gives N plus one pins for N rails instead of two per rail. The 5 mA sink guarantee at temperature is what sets the pull-up: a 10 k pull-up to 3.3 V sinks 330 uA and leaves the output low enough for any 3.3 V input, while a 1 k pull-up would consume the whole 5 mA budget and still work only at 25 C.

ParameterPublished valueWhat it decides
Reference400 mV plus or minus 0.275 percent1.1 mV at the node, 9.1 mV on a 3.3 V rail
Supply range1.7 V to 5.5 VWorks on 1.8 V, 3.3 V and 5 V rails
Supply current8.55 uA maximum75 mAh over a year
Hysteresis9.2 mV typical76 mV at the rail, stops chatter
Input biasplus or minus 2.5 nA maximum0.25 mV on a 100 k divider
OutputsPWRGD and OV, open drainN plus one processor input for N rails
Sink current5 mA over temperatureSets the smallest pull-up resistor
Temperature-40 C to +125 CSuits an industrial board

Does the order code change the function?

The ADCMP671 family is offered in more than one order code and the output arrangement is part of the code, not a cosmetic suffix. A buyer replacing a part in a socket needs the same code, because a device with a different output pairing will fit the footprint and report the wrong condition. The verification steps for that kind of replacement, including comparing the output function and not only the package, are on the drop in replacement page.

What happens on a rail that never comes up?

Both comparators run from the rail they are watching only if that rail is supplied to the part, which is why the supply range starting at 1.7 V matters: the monitor can be powered from a rail that is itself below its final value and still report correctly once it is above 1.7 V. Below that, the outputs are unpowered and the pull-ups read high, so a board that relies on PWRGD being low during a dead rail needs the pull-up on a separate always-on supply. The rest of the supervisory parts on the site are grouped on the power management cross reference, and the complete interface and converter index is the analog and mixed-signal index.