ADA4177-2ARZ
Product Specifications
ADA4177-2ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADA4177-2ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADA4177-2ARZ: 32 V overvoltage protected precision amplifier with an EMI filter
The ADA4177-2ARZ is a dual precision amplifier in an 8-lead SOIC that survives an input 32 V beyond either supply and still holds a 60 uV maximum offset and 1 uV/C maximum drift. The input stage carries an integrated electromagnetic interference filter, quoted at 70 dB of rejection at 1000 MHz and 90 dB at 2400 MHz. It is the part for a front end that is wired to the outside world, where the fault and the radio frequency field arrive before the signal does.
Published values
| Parameter | Value |
|---|---|
| Offset voltage | 60 uV maximum at 25 C in the 8-lead SOIC |
| Offset voltage drift | 1 uV/C maximum over -40 to +125 C |
| Input bias current | 1 nA maximum at 25 C |
| Voltage noise density | 8 nV per root hertz typical at 1 kHz |
| Large signal voltage gain | 100 dB minimum over supply and temperature |
| Gain bandwidth product | 3.5 MHz typical at a gain of 100 |
| -3 dB bandwidth | 6 MHz typical at unity gain |
| Supply current per amplifier | 500 uA typical |
| Supply range | plus or minus 2.5 V to plus or minus 18 V, specified at plus or minus 5 V to plus or minus 15 V |
| Input overvoltage protection | 32 V above and below either supply rail |
| EMI rejection | 70 dB typical at 1000 MHz, 90 dB typical at 2400 MHz |
| Capacitive load | stable above 1000 pF with no external compensation |
| Long term drift | 2 uV typical over 10,000 hours |
| Package | 8-lead SOIC_N |
60 uV is a different class from 1 mV
On a 5 V span a 16-bit code is 76.3 uV, so a 60 uV maximum offset is 0.8 codes, and the 1 uV/C drift over 165 C adds 165 uV or 2.2 codes. A channel built around this part therefore holds about three codes of offset error over the industrial range without trimming, which is why it appears in thermocouple, RTD and strain gauge channels rather than in general purpose signal routing.
The bias current is the other half of the story. One nanoamp into a 1 Mohm source is 1 mV, which is sixteen times the offset, so a high impedance sensor still needs the source impedance held down or the part chosen for its bias instead of its offset. A 10 kohm bridge is 10 uV of bias error and that is the regime this amplifier was bought for.
What 32 V of protection actually covers
The inputs tolerate 32 V beyond either rail, which covers a 24 V industrial loop that is accidentally connected to a 32 V bus, a hot plugged connector, and the inductive kick of a relay coil on the same harness. It does not cover a lightning surge: that is a job for a series resistor and a transient suppressor ahead of the pin, and the on chip protection is the second line rather than the first.
The protection also removes the phase reversal that older precision amplifiers show when an input is driven past the common mode range. In a multiplexed channel that is the difference between a glitch and a channel that stays in range while the multiplexer settles.
The EMI filter is not a filter on the signal
The integrated filter attenuates what arrives at the input pins in the radio bands, 70 dB at 1 GHz and 90 dB at 2.4 GHz, which is where a hand held transmitter and a WiFi router put their energy. It does not replace the differential and common mode capacitors on the board, and it does not stop a 50 Hz or 60 Hz component. It is there so that a 1 V per metre field does not turn into a dc offset in a 60 uV channel.
The 3.5 MHz gain bandwidth and 6 MHz open loop bandwidth are modest on purpose: a precision channel that has to reject a radio field does not want a 50 MHz front end. A 500 uA per amplifier supply current keeps a dual at 1 mA, which is what makes the part usable in a loop powered transmitter.
Sourcing notes for this family: the amplifier cross reference holds the cross references, medical device components is the pre substitution check, and how to verify a drop in replacement is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask
What happens if the input is driven to 40 V with a 15 V supply? The input is protected to 32 V beyond the rail, so 40 V on a 15 V supply is 25 V beyond the rail and inside the rating. Beyond 32 V the internal clamps conduct and the current has to be limited by the source impedance, so a hard 60 V fault still needs an external resistor.
Does the ADA4177-2 need a guard ring on the board? Not for the 1 nA bias current on a clean board, but a 1 nA leakage path across the surface of a humid board is the same size as the bias, so a guard trace or a conformal coat is the answer when the channel sits below 10 nA of total input current.