ADA4084-2ARMZ-R7
Product Specifications
ADA4084-2ARMZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADA4084-2ARMZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADA4084-2ARMZ-R7: 30 V Rail-to-Rail at 0.625 mA per Amplifier
The ADA4084-2ARMZ-R7 is a dual operational amplifier from Analog Devices in an 8-lead MSOP. It runs from a single 3 V to 30 V supply or a plus and minus 1.5 V to plus and minus 15 V split supply, with rail-to-rail inputs and rail-to-rail outputs. Supply current is 0.625 mA typical per amplifier at plus and minus 15 V, gain bandwidth product is 15.9 MHz at a gain of 100, unity gain crossover is 9.9 MHz, closed loop bandwidth at minus 3 dB is 13.9 MHz, slew rate is 4.6 V per microsecond, and input voltage noise is 3.9 nanovolts per root hertz at 1 kHz. Maximum offset voltage is 100 microvolts, long term drift over 10,000 hours is 3 microvolts typical, and temperature hysteresis is 4 microvolts typical. The part is unity gain stable and specified from -40 C to +125 C.
15.9 MHz of gain bandwidth becomes 159 kHz at a gain of 100
The gain bandwidth product is quoted at a gain of 100, so the closed loop bandwidth there is 159 kHz and the small signal response is a single pole from about that frequency. At a gain of 10 it is 1.59 MHz and at unity gain the crossover is 9.9 MHz. This is the number that decides whether the amplifier can carry a 100 kHz signal at a gain of 100, and it cannot: the loop has run out of gain well before that. It also decides the settling time, because a 159 kHz pole has a 1 microsecond time constant and settling to 0.01 percent needs about 9.2 of them, so roughly 9 microseconds per step. A multiplexed 250 kSPS front end has 4 microseconds per conversion, which is less than one such step.
4.6 V per microsecond is 146 kHz of full power bandwidth
Slew rate and bandwidth are separate limits and the lower one wins. A 10 V peak to peak sine at 146 kHz needs the full 4.6 V per microsecond, so above that frequency the output is a triangle rather than a sine no matter what the small signal bandwidth says. At plus and minus 15 V the output can swing close to 30 V peak to peak, and the same slew rate then limits full power bandwidth to about 49 kHz. The practical consequence for a filter stage is that the corner frequency and the amplitude have to be checked together: a 100 kHz low pass at 1 V peak to peak is comfortable, and the same filter at 10 V peak to peak is not.
Where the 100 microvolt offset claim applies
The product page attaches the 100 microvolt maximum offset to the SOIC package, and the part on this page is the 8-lead MSOP. That is not a rounding detail: offset voltage grades in this family are package dependent, so a board built for the MSOP has to be checked against the MSOP column of the data sheet rather than against the headline. The two other error terms that survive a calibration are the 3 microvolts of long term drift over 10,000 hours and the 4 microvolts of temperature hysteresis, which together are 7 microvolts, or 7 percent of the maximum offset. Calibration at production removes the initial offset and leaves those two terms plus drift, which is why a 16-bit system can use a 100 microvolt part after all.
| Parameter | Published value | What it decides |
|---|---|---|
| Supply | 3 V to 30 V, or plus and minus 1.5 V to 15 V | 12 V and 24 V industrial rails |
| Supply current | 0.625 mA per amplifier at 15 V | 18.75 mW for the dual |
| Gain bandwidth | 15.9 MHz at a gain of 100 | 159 kHz closed loop at that gain |
| Unity gain crossover | 9.9 MHz | Unity gain stable |
| Slew rate | 4.6 V per microsecond | 146 kHz at 10 V peak to peak |
| Noise | 3.9 nV per root hertz at 1 kHz | 1.23 uV RMS over 100 kHz |
| Offset | 100 uV maximum, SOIC | Check the MSOP column |
| Long term drift | 3 uV over 10,000 hours | Survives calibration |
| Hysteresis | 4 uV typical | Second term that survives calibration |
| Temperature | -40 C to +125 C | Industrial, not automotive grade |
Can this drive a 16-bit converter?
Yes, with the noise budget checked rather than assumed. A 16-bit converter on a 5 V range has a 76 microvolt least significant bit, and the amplifier's 1.23 microvolts RMS over a 100 kHz band is 1.6 percent of that, so the amplifier is not the limit. Over the 10 kHz band a converter at 20 samples per second uses, the 3.9 nanovolts per root hertz becomes 0.39 microvolts RMS, which is 0.5 percent of an LSB. The limit moves to the reference, the source impedance and the settling, in that order. At a gain of 100 the 159 kHz closed loop bandwidth is what sets settling, and a converter with a short acquisition window needs the first stage to be faster than this one.
What survives 10,000 hours and a thermal cycle?
The 3 microvolts of long term drift and 4 microvolts of hysteresis are the two terms that a production calibration cannot remove, and together they are 7 microvolts. Over a 16-bit LSB of 76 microvolts that is 9 percent, so a calibrated 16-bit channel stays inside its error band with this amplifier. A part with a 25 microvolt drift term would consume a third of the same band, which is where the choice between grades starts to matter. Related amplifiers are compared on the amplifier cross reference, the instrumentation cases with a patient connected are on the medical device components page, and the full category is the analog and mixed-signal index.
Request Quote — In Stock, 100% New & Original, Full Warranty