AD8436ARQZ-R7
Product Specifications
AD8436ARQZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD8436ARQZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD8436ARQZ-R7: a true rms reading from 100 microvolts, and the 10 percent an averaging meter hides
The AD8436ARQZ-R7 is a translinear true rms to dc converter from Analog Devices, built for instruments that have to read the heating value of a waveform rather than its average. It covers 100 microvolts rms to 3 V rms without a range change, holds plus or minus 10 microvolts plus 0.25 percent of reading on the B grade, and draws 300 microamps from a plus or minus 2.4 V supply. A high impedance FET buffer and a precision output buffer are both on the die.
What the vendor publishes
| Parameter | Value |
|---|---|
| Function | true rms or average rectified value, selectable |
| Accuracy | plus or minus 10 microvolts plus or minus 0.25 percent of reading, B grade |
| Input range | 100 microvolts rms to 3 V rms, 8.5 V peak to peak full scale |
| Bandwidth | 1 MHz at minus 3 dB for 300 mV, 65 kHz for an extra 1 percent |
| Crest factor | accurate to 10 |
| Output offset | zero dc offset |
| Input impedance | 10 to the 12 ohm or more, 2 pF or less |
| Supply current | 300 microamps typical at plus or minus 2.4 V |
| Supply | dual 2.4 V to 18 V, single 4.8 V to 36 V |
| Packages | 4 x 4 mm LFCSP, 8 x 6 mm QSOP |
Form factor, and why an averaging meter is wrong on some waveforms
An averaging meter is calibrated to read the rms of a sine, using a form factor of 1.1107. Feed it a square wave and it reads 1 divided by 1.1107, which is 90.03 percent of the true value, an error of 9.97 percent low. A triangle comes out at a form factor of 1.109, which is within 0.15 percent of a sine, so the same meter is right on a triangle and wrong on a square. Phase controlled waveforms from triacs and the current drawn by a switch mode supply have neither shape, and that is where a true rms converter stops being a luxury.
The bottom of the range and the accuracy at the test point
At 300 mV rms, the point where the part is specified, the error is 10 microvolts plus 0.25 percent of reading, which is 760 microvolts, or 0.253 percent. The 100 microvolt floor is 80 dB below 1 V rms, and the top of the range at 3 V rms is plus 9.54 dBV, so the part covers a 90 dB input range without switching anything. Larger inputs are handled by an external divider, which is a resistor choice rather than a second range.
Crest factor and the peak the input actually sees
A crest factor of 10 on a 300 mV rms reading means the input peaks at 3 V, which is inside the 8.5 V peak to peak window that corresponds to 3.005 V rms of sine. That headroom is what makes a short duration pulse train readable without clipping the buffer. The bandwidth numbers run from 65 kHz for an extra 1 percent of error to 1 MHz at minus 3 dB, a ratio of 15.4, so a specification written at 20 kHz is comfortably inside the flat part while one written at 500 kHz is not. Power is 1.44 mW at plus or minus 2.4 V, which is why the part appears in handheld multimeters.
Two questions buyers ask
True rms or average rectified output? The part offers both. Average rectified is the cheaper reading to digitise and is what a legacy meter with an averaging scale expects, so a replacement has to match the output mode of the instrument, not just the package.
Is 1 MHz enough for a switching supply measurement? For the fundamental of a 20 kHz converter yes, with margin. For the edges, no converter measures them as rms, and the reading that matters is the one taken after the anti alias filter that the instrument already has.
SUPERB quotes the AD8436ARQZ-R7 against this row and confirms the grade and package before shipment. Amplifier and converter alternatives are compared under amplifier cross reference, delivery on a build waiting for parts is covered by component lead time solutions, and the category index is analog and mixed signal ICs.
Request Quote — In Stock, 100% New & Original, Full Warranty