Contact Us

AD8314ARMZ-REEL7

Brand: Analog Devices
Analog Devices AD8314ARMZ-REEL7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD8314ARMZ-REEL7 — Analog & Mixed-Signal ICs | Superb Automation

AD8314ARMZ-REEL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD8314ARMZ-REEL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

AD8314ARMZ-REEL7: an RF detector for 100 MHz to 2.7 GHz with a 45 dB range

What this order code is

AD8314ARMZ-REEL7 is a complete RF detector and controller in an 8-lead MSOP, covering 100 MHz to 2.7 GHz with a nominal 45 dB of dynamic range. It converts an RF input into a temperature stable, linear in decibels output, which is what a power control loop needs: a voltage that moves by a fixed number of millivolts per decibel rather than a diode response that has to be linearised in software.

The specified input range is minus 58 dBV to minus 13 dBV, which the vendor also states as minus 45 dBm to 0 dBm referred to 50 ohms. Response to a 10 dB step is 70 ns. Supply current is 4.5 mA from 2.7 V to 5.5 V, which is 12 mW at the low end, and the power down current is 20 microamps. The part is specified from minus 40 to plus 85 degrees C with the temperature stability quoted over the full range, and it is offered in an 8-lead LFCSP as well as the MSOP.

Parameters as published

ItemValue
Frequency range100 MHz to 2.7 GHz
Dynamic range45 dB nominal
Input rangeminus 58 dBV to minus 13 dBV, minus 45 dBm to 0 dBm in 50 ohms
Response time70 ns to a 10 dB step
Transfer functionlinear in decibels, temperature stable
Supply current4.5 mA
Power at 2.7 V12 mW
Shutdown current20 microamps
Supply range2.7 V to 5.5 V
Temperature rangeminus 40 to plus 85 degrees C
Package8-lead MSOP, 8-lead LFCSP alternative
Functiondetector and controller, complete subsystem

Numbers that decide the application

Minus 45 dBm is 31.6 microwatts and 0 dBm is 1 milliwatt, so the detector spans a 31.6 to 1 range of power, 45 dB. In voltage terms into 50 ohms that is 1.26 mV rms at the bottom and 0.316 V peak at the top, which is the range the input matching network has to present without attenuation. A coupler that delivers more than 0 dBm to this pin pushes the part out of its specified window at the top of the transmit power range.

The 45 dB range is the number that decides what the loop can control. A power amplifier with 35 dB of gain variation over temperature and frequency fits inside it with 10 dB to spare; one with 50 dB of variation does not, and needs either a step attenuator ahead of the detector or two detectors with different coupling factors. That comparison is the first thing to do with this part, before any question of accuracy.

Seventy nanoseconds to a 10 dB step is the response of the detector itself. A closed loop built around it will be slower, because the loop filter and the power amplifier's own settling dominate, but the detector does not limit a loop that closes at a few hundred kilohertz. The 4.5 mA supply is 12.1 mW at 2.7 V, and the 20 microamp shutdown is 225 times lower, so a receiver that only needs the detector during transmit can gate it from the same control line that enables the amplifier.

Selection and cross reference notes

Detectors in this class differ in three ways: frequency range, dynamic range and whether the output is linear in decibels or in volts. A part with a wider range and a different slope is not a substitute in a calibrated loop, because the calibration constants in the firmware are tied to the slope and the intercept. A part with the same slope and a narrower frequency range may be a substitute if the band is covered.

The MSOP and LFCSP bodies share a datasheet and differ in footprint and thermal path. A board qualified with one cannot take the other without a land pattern change, and the part number suffix is the only clue.

Where it fits

Cellular handsets, base station power control, transmitter leveling loops and any RF chain where a measured power has to feed a control loop. The temperature stable logarithmic response is what allows a factory calibration at one temperature to hold over the operating range, and the 70 ns response allows the loop to track bursts. Buyers working on RF chains can start at the RF component sourcing page, and teams checking availability on RF parts usually use the component lead time solutions page.

Buying notes

ARMZ is the 8-lead MSOP and REEL7 is the reel; the LFCSP body carries a different suffix. Because the frequency range and the range in decibels are the two selection criteria, a quotation should state both, and a part offered as an equivalent should be checked on slope as well as on band.

Sourcing notes and next step

RF detectors are a category where the equivalent part often differs in slope, which only shows up after calibration. We quote the exact code and check the frequency range and the transfer function before offering anything else. Send the codes and quantities through the RF component sourcing page and we will answer with availability and the parameters a substitute would change.

Request Quote — In Stock, 100% New & Original, Full Warranty