Contact Us

AD7888ARZ

Brand: Analog Devices
Analog Devices AD7888ARZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7888ARZ — Analog & Mixed-Signal ICs | Superb Automation

AD7888ARZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7888ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7888ARZ: Eight Channels at 125 kSPS With a 2.5 V Reference Inside

The AD7888ARZ is a 12 bit converter with eight single ended inputs, a 125 kSPS throughput rate and an internal 2.5 V reference, in a 16-lead body. The supply range is 2.7 V to 5.25 V, shutdown current is 1 uA maximum, and the input track and hold acquires a signal in 500 ns. Because the reference is inside the package and brought out on a pin, the part can run from a single supply with no external reference, or it can be driven from a more accurate external reference when the internal one is not good enough. The interface is serial and compatible with SPI, QSPI, MICROWIRE and DSP hosts.

Published values

ParameterValue
Resolution12 bits
Inputs8 single ended
Throughput125 kSPS
Supply2.7 V to 5.25 V
ReferenceInternal 2.5 V, brought out on a pin
Acquisition time500 ns
Shutdown current1 uA maximum
Input rangeZero to the reference voltage on each channel
InterfaceSerial, SPI, QSPI, MICROWIRE and DSP compatible
Bodies16-lead narrow SOIC and TSSOP

A reference inside the package is a system level decision

An internal reference removes a component, a trace and a decoupling capacitor, which is why it appears in instruments that are built in volume and priced tightly. What it does not remove is the reference error: the internal reference has its own initial tolerance and drift, and those terms sit directly in the measurement error budget. Where the channel has to hold 12 bit accuracy over temperature, the internal reference is usually the limiting element and an external reference on the same pin is the answer. Where the measurement is relative or the temperature is controlled, the internal reference is enough and the board is simpler.

Shutdown and the burst mode instrument

At 1 uA in shutdown the converter can be parked between measurements, which makes a battery instrument that reads eight channels once a minute practical. The wake up time then becomes the parameter that sets the measurement period, because the internal reference has to settle as well as the converter. The data sheet gives the wake up sequence from shutdown, and a firmware that starts converting before the reference has settled produces a first reading that is low and a second reading that is correct, which in a data logger looks like a glitch rather than a timing error.

500 ns acquisition and the source impedance limit

A 500 ns acquisition window at 125 kSPS sets a hard limit on the source impedance the converter can tolerate. The sampling capacitor has to charge through the source resistance and the switch resistance within that window, so a source above a few kilohms leaves the capacitor short of the final value and the reading falls. A buffer or a capacitor at the input relaxes the limit, and the capacitor value is chosen so that the charge it gives up during acquisition is small compared with half an LSB at 12 bits. This is the single most common reason a working prototype reads low when it moves to a board with longer traces.

Eight channels and the ground return

Single ended inputs share a ground, so the return path from the sensors has to be treated as part of the measurement. In an instrument with eight sensors spread across a chassis, the ground differences between the sensors appear directly in the readings. Bringing the returns together at the converter's ground pin rather than at the chassis, and keeping the digital return separate, is the usual fix. Where the sensors are electrically isolated, the ground question disappears and the eight channels can be read in any order. The converter cross reference page lists the eight channel parts we hold by rate and body, the ADI part second source page shows equivalents, and the medical device components page covers the requirements that apply when the same channel is used in a patient connected instrument.