AD7401AYRWZ
Product Specifications
AD7401AYRWZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD7401AYRWZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD7401AYRWZ: The Same Barrier and the Same 16 Bits, Clocked From Outside at 20 MHz
The AD7401 is the external clock member of the isolated sigma delta modulator family. It has the same second order modulator, the same on board reference and the same on chip digital isolator as the internally clocked part, but the sampling clock comes from the host, up to 20 MHz, instead of from an internal 10 MHz oscillator. Input range is plus and minus 200 mV with a 320 mV full scale, resolution is 16 bits with no missing codes, integral nonlinearity is 2 LSB typical, offset drift is 3.5 uV per degree C maximum, supply current rises to 20 mA maximum at 5.25 V, and the isolation rating is 5000 V rms for one minute under UL 1577 with a working voltage of 891 V peak under the CSA and VDE standards. It comes in a 16-lead SOIC over minus 40 to plus 105 degrees C.
20 MHz of external clock gives the host control of the sample instant
An external clock means the host decides when the modulator samples, so several modulators can be clocked from one source and their bit streams are synchronous. That matters in a three phase inverter: three currents sampled at slightly different instants produce a vector that rotates slightly, and the error shows up as a torque ripple at the difference frequency. With a shared clock the three streams are aligned to within the clock skew, and the filter outputs can be compared directly. The internal clock version cannot do this because each part has its own oscillator, and two oscillators at 10 MHz are never exactly equal.
891 V of working voltage against 645 V on the other member
The working voltage rating of 891 V peak under CSA and VDE is higher than the 645 V peak of the internally clocked version, which is a package and creepage difference rather than a modulator difference. That rating is what allows the part on a 690 V class drive where the bus plus the transient headroom exceeds 645 V. Both parts carry the same 5000 V rms one minute UL withstand, so the withstand number cannot be used to choose between them. The working voltage, the creepage and the pollution degree are the numbers that decide.
| Parameter | Value | What it decides |
|---|---|---|
| Clock | External, up to 20 MHz | Host controlled sampling, shared between channels |
| Input range | Plus and minus 200 mV, 320 mV full scale | 4.88 uV per code at 16 bits |
| Resolution | 16 bits, no missing codes | 0.49 mA per code on a 10 milliohm shunt |
| Integral nonlinearity | 2 LSB typical | 9.8 uV, below the drift term |
| Offset drift | 3.5 uV per degree C maximum | 507 uV over 145 degrees, 104 codes |
| Isolation, UL | 5000 V rms for one minute | Production withstand test |
| Isolation, working | 891 V peak under CSA and VDE | The continuous voltage the barrier may see |
| Supply current | 20 mA maximum at 5.25 V | 105 mW on the isolated side |
| Secondary supply | 5 V or 3 V | Direct connection to a 3.3 V host |
| Output rate | 78.1 kSPS at 20 MHz and a 256 ratio | The rate a matching filter delivers |
| Reference | On board | No reference across the barrier |
| Package and range | 16-lead SOIC | Minus 40 to plus 105 degrees C |
| Output | One bit density stream | Reconstruction is the host's job |
Clock jitter becomes a gain error
A sigma delta modulator samples continuously, and the clock edge position is the sampling instant. Jitter on that edge modulates the sampling interval, which for a changing input appears as noise and, in a current measurement, as a gain uncertainty that depends on the rate of change of current. At 20 MHz a 1 ns of jitter is 2 percent of a clock period, and on a 50 Hz current with a sinusoidal shape the resulting noise is small. On a switching waveform with fast edges it is not, and the clock source has to be a clean one, preferably the same source that clocks the converter on the other side of the barrier so that the two are coherent.
The 20 mA and the isolated supply
Twenty milliamps at 5.25 V is 105 mW, about 10 percent more than the internally clocked part, and it comes from the isolated supply that also feeds the shunt amplifier and the gate driver's low side. That budget is set early in a drive project and is difficult to change later, so the modulator current is one of the first numbers to add up when the isolated supply is sized. Three of these parts plus three shunt amplifiers is a load that a small flyback or a push pull transformer can carry, and the transformer's own isolation rating then becomes part of the barrier that has to be certified.
Sourcing an externally clocked isolated modulator
The difference between this part and its internally clocked sibling is a pin and a clock source, so a substitution in either direction changes the board and the firmware together. Parts that can be compared on input range, isolation rating and clock arrangement are listed in ADC DAC cross reference, the drive and power stage side of a bill of materials is covered in power management cross reference, and the incoming check for a certified isolation part is in incoming inspection plan.