AD7175-2BRUZ-RL7
Product Specifications
AD7175-2BRUZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD7175-2BRUZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD7175-2BRUZ-RL7: 24 Noise Free Bits at 20 SPS and 17.2 at 250 kSPS
The AD7175-2BRUZ-RL7 is a multiplexed sigma-delta analog to digital converter from Analog Devices in a 24-lead TSSOP. It has two fully differential or four single ended inputs behind a crosspoint multiplexer, an output data rate from 5 samples per second to 250 kSPS, and a channel scan rate of 50 kSPS per channel with 20 us of settling. Noise free resolution is 17.2 bits at 250 kSPS, 20 bits at 2.5 kSPS and 24 bits at 20 SPS, with integral nonlinearity of plus or minus 1 ppm of full scale. The internal reference is 2.5 V with 2 ppm per degree C of drift, the analog and reference inputs have true rail to rail buffers, and rejection of 50 Hz and 60 Hz is 85 dB at 27.27 SPS with 50 ms of settling. The converter draws 8.4 mA from a 5 V AVDD1 and is specified from -40 C to +105 C.
Resolution is a rate dependent number, and the table says so
On a 5 V full scale, 17.2 noise free bits at 250 kSPS is 33 uV peak to peak, 20 bits at 2.5 kSPS is 4.8 uV, and 24 bits at 20 SPS is 0.30 uV. The gap between the fastest and the slowest setting is 6.8 bits, a factor of 111 in noise, which is the same converter trading bandwidth for resolution through its digital filter. A specification that quotes only 24 bits describes the 20 SPS corner, and a control loop that runs at 250 kSPS gets 17.2 bits whatever the marketing line says. Choosing the output data rate is therefore the first decision, and the filter options follow from it.
The internal reference is good, and it is still the accuracy limit at low rates
Two ppm per degree C across 145 C is 290 ppm, or 725 uV on a 2.5 V reference, while the converter's own noise at 20 SPS is 0.30 uV peak to peak. The reference drift is three orders of magnitude larger than the noise in that corner, so a DC measurement that needs absolute accuracy is limited by the reference, not by the converter. A ratiometric measurement removes the reference from the error budget entirely because the same excitation feeds the reference input, and an external reference is the answer when the measurement has to be absolute. The converter's integral nonlinearity of plus or minus 1 ppm of full scale is 5 uV on a 5 V range, which sits between the two.
Two channels scan at 50 kSPS each, one channel can run at 250 kSPS
Twenty microseconds of settling is one conversion, so a scan across two channels returns 50 kSPS on each, while a single channel can use the full 250 kSPS output rate. Each channel can carry its own setup with its own filter and gain, but changing setup between channels adds settling time on top of the 20 us, which is where a scan loses rate in practice. The 85 dB rejection of both line frequencies is tied to an output data rate of 27.27 SPS and a 50 ms settling window, so a board that needs mains rejection has to run at that rate and accept the latency that comes with it.
| Parameter | Published value | What it decides |
|---|---|---|
| Inputs | 2 differential or 4 single ended | Crosspoint multiplexer, per channel setup |
| Output rate | 5 SPS to 250 kSPS | Sets the resolution available |
| Noise free bits | 17.2 at 250 kSPS, 24 at 20 SPS | 33 uV against 0.30 uV on 5 V |
| Integral nonlinearity | plus or minus 1 ppm of full scale | 5 uV on a 5 V range |
| Reference | 2.5 V, 2 ppm per degree C | 725 uV over 145 C |
| Line rejection | 85 dB at 27.27 SPS | Tied to rate and 50 ms settling |
| Supply current | 8.4 mA from 5 V | 42 mW for the converter |
| Temperature | -40 C to +105 C | Rules out a 125 C ambient |
What does the supply arrangement allow?
AVDD1 is 5 V, or plus and minus 2.5 V for a split supply, while AVDD2 and IOVDD run from 2 V to 5 V. That means the digital side can sit at 3.3 V or 1.8 V without a level shifter, and the analog side can be bipolar for a signal that swings around ground. A single 5 V rail is the simpler arrangement, and the true rail to rail buffers are what let a signal close to either rail be converted without an external amplifier.
Is it a replacement for a 24-bit converter that runs at 10 SPS?
Only if the extra rate is wanted. At 20 SPS the noise free resolution is the same 24 bits, so the part covers the slow application as well as the fast one, and the added cost is the higher supply current and the more complex digital interface. The matching converters and references are grouped on the ADC and DAC cross reference, the patient monitoring and instrument cases are on the medical device components page, and the complete index is the analog and mixed-signal index.
Request Quote — In Stock, 100% New & Original, Full Warranty