Contact Us

AD7172-2BRUZ

Brand: Analog Devices
Analog Devices AD7172-2BRUZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7172-2BRUZ — Analog & Mixed-Signal ICs | Superb Automation

AD7172-2BRUZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7172-2BRUZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7172-2BRUZ: 24 Bits, 31.25 kSPS and 1.5 mA

The AD7172-2BRUZ is a 24 bit sigma delta converter with two fully differential or four single ended inputs, a crosspoint multiplexer, and true rail to rail buffers on both the analog inputs and the external reference inputs. Output rate is programmable from 1.25 samples per second to 31.25 kSPS, the noise free resolution is 24 bits at 5 samples per second, and the part rejects 50 Hz and 60 Hz by 85 dB with a 50 ms settling time. Supply current is 1.5 mA at a 27.27 samples per second output rate, on an analog supply of 3.0 V to 5.5 V and a digital supply of 2 V to 5.5 V. The interface is SPI, QSPI, MICROWIRE and DSP compatible.

Published values

ParameterValue
Resolution24 bits
Output rate1.25 samples per second to 31.25 kSPS
Noise free bits24 at 5 samples per second
Channels2 fully differential or 4 single ended, crosspoint multiplexer
Input buffersTrue rail to rail, on inputs and reference
Line rejection85 dB at 50 Hz and 60 Hz with 50 ms settling
Analog supply3.0 V to 5.5 V
Digital supply2 V to 5.5 V
Supply current1.5 mA at 27.27 samples per second
InterfaceSPI, QSPI, MICROWIRE, DSP, with GPIO for external multiplexer control

Why rail to rail buffers change the front end

A sigma delta converter without input buffers presents a switched capacitor load to the sensor, and the charge that flows at each sampling instant has to come from somewhere. With a high impedance source the result is a gain error that depends on the source resistance and the sampling rate, which is why unbuffered converters need an external amplifier. The integrated buffers here are true rail to rail, so the input can sit at either supply rail without the buffer running out of headroom, and the source only has to supply the buffer bias current. The same applies to the reference input, which is where the buffer matters even more, because the reference sees the full switching charge of the modulator.

50 Hz and 60 Hz rejection in one setting

An 85 dB rejection of both line frequencies at the same time is not the same as rejecting one of them. Instruments that are sold in both 50 Hz and 60 Hz markets either need two filter settings or a single setting that covers both, and the second option removes a configuration step that is easy to get wrong in production. The 50 ms settling time is the cost: a channel change or a gain change needs 50 ms before the reading is valid, which sets the maximum scan rate for a multiplexed instrument to about 20 channels per second. Where faster scanning is needed, the line rejection has to be traded away, and the data sheet gives the relationship between output rate and rejection.

Crosspoint multiplexer and per channel setup

The crosspoint multiplexer allows any input pair to be routed to the modulator in any order, and each channel can carry its own setup, including gain, filter and calibration registers. That is what makes the part usable in a multi sensor instrument without external switching logic. General purpose outputs can drive an external multiplexer in step with the conversion, which extends the channel count beyond the four on the die. The caution is that a per channel setup change costs the settling time, so an instrument that alternates between two filter settings on every channel gives up most of its throughput.

Power and the 24 bit claim

At 1.5 mA and a 5 V analog supply the part dissipates about 8 mW, which is low for a converter that resolves 24 noise free bits at 5 samples per second. The 24 bit figure is a noise free resolution, not an accuracy figure, and the accuracy is set by the reference, the gain drift and the thermocouple or bridge that feeds it. An instrument specification that quotes 24 bits of accuracy from this converter alone is overstating what the silicon can do, and the honest specification comes from the error budget of the whole channel. The converter cross reference page groups the sigma delta parts we hold by resolution and rate, the ADI part second source page covers equivalents, and the medical device components page covers the long life requirements that apply when the same channel goes into a diagnostic instrument.