Contact Us

TJA1055T/1

Brand: NXP Semiconductors
NXP Semiconductors TJA1055T/1 is a mcu & embedded component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TJA1055T/1 — MCU & Embedded Processors | Superb Automation

TJA1055T/1

NXP Semiconductors — MCU & Embedded Processors

Product Overview

The TJA1055T/1 from NXP Semiconductors is a microcontroller / embedded processor engineered for real-time control, signal processing, and connectivity. NXP Semiconductors provides secure connectivity solutions, embedded processors, and automotive-grade MCUs for edge computing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • ARM Cortex / RISC-V / proprietary core with high-performance real-time processing
  • Integrated flash memory and SRAM for efficient code execution
  • Rich peripheral set: UART, SPI, I2C, ADC, timers, PWM
  • Low-power modes for battery-operated and energy-sensitive applications
  • Hardware security features: secure boot, crypto accelerator, TRNG
  • Extensive development ecosystem with IDE, HAL, and RTOS support

Key Specifications

Core—
Max FrequencyMHz
FlashKB
SRAMKB
GPIO—
ADCbits
Interfaces—
Supply VoltageV
Operating Temp°C
Package—

Applications

Industrial Motor Control IoT Edge Nodes Consumer Electronics Automotive Body Control Smart Home & Appliances Medical Portable Devices

Request Quote — In Stock, 100% New & Original, Full Warranty

TJA1055T/1: SO14 fault tolerant CAN transceiver for 5 V logic

TJA1055T/1 is the fault tolerant CAN transceiver in the SO14 body with 5 V logic levels and a pull-up on the termination pin in the TJA1055 fault tolerant CAN transceiver line, described by Rev 5 of 6 December 2013. It is the plain member of the fault tolerant line: 125 kBd, differential operation with single wire fallback, and 5 V logic. It is the code that most existing fault tolerant boards carry, and the one to compare against the /3 code before a 3.3 V controller is dropped in beside it.

Order code and package

Order codeTJA1055T/1
Variant function on pin 5STB, EN and WAKE inputs with INH and ERR outputs, and 5 V compatible push-pull logic on this code
PackageSO14, 3.9 mm body width, 14 pins
Protocolfault tolerant low speed CAN per ISO 11898-3, with differential and single wire operation
Maximum data rateup to 125 kBd
Supply voltage on VCC4.75 to 5.25 V
Logic supply on VIOnot present as a separate pin; the /3 code accepts 3 V logic levels
Temperature rangeminus 40 to plus 150 C virtual junction
QualificationAEC-Q100
DatasheetRev 5 of 6 December 2013

Electrical parameters that decide the application

Bus fault voltageminus 58 to plus 58 V on CANH and CANL with the supply at 0 V and no time limit
Supply currentSleep mode current is reduced to a minimum and wake-up is signalled on RXD and ERR with VCC off
Electrostatic discharge6 kV IEC 61000-4-2 on the off-board pins
Thermal resistance120 K/W junction to ambient in the SO14 body, 40 K/W junction to solder point
Wake and diagnostic pinsSTB, EN and WAKE inputs, INH output, ERR output indicating the failure mode, and automatic single wire fallback
Bus pinsCANH and CANL, differential, with the recessive level set by the on chip driver or by a SPLIT output where the code carries one
Logic levels5 V logic levels on TXD, RXD, STB, EN and ERR, with RXD and ERR as push-pull outputs
Behaviour with the supply offthe transceiver disengages from the bus so an unpowered node does not load the network
ProtectionTXD dominant time-out, undervoltage detection and thermal shutdown are named in every document in this family
Ordering stringthe suffix after the slash carries the body, the packing and the variant, so it has to be quoted in full on a purchase order

Points to check before this part goes on a BOM

RXD and ERR are push-pull on this code and open drain on the /3 code. A board that moves between them without removing the pull-ups ends up with two drivers on the same net, which reads as a stuck dominant bus rather than as a population fault.

The TXD input current is 40 to 160 microamps at 3 V on this code against 2 to 21 microamps on the /3 code. That is a threshold difference, not a leakage figure, and it is why a 3.3 V driver with a weak high side can fail to release TXD on the 5 V part.

Fault tolerance here means differential operation first and single wire second. A short between CANH and CANL, a short to ground or to battery, or a break in one wire each move the network into a defined degraded mode that the ERR output identifies.

The bus stands minus 58 to plus 58 V with the supply at 0 V and no time limit, which is a wider window than the high speed parts need and is there for a harness that can be shorted anywhere.

Termination is per node and switched, so the RTL and RTH pins carry the local termination only while the node is powered. On a bus with many nodes the total load therefore tracks the number of powered nodes, which is the opposite of a passive high speed bus.

Electrostatic discharge is 6 kV IEC 61000-4-2 on the off-board pins and 8 kV human body model on the bus pins, with 4 kV on the rest. On a harness that leaves the enclosure, that is still a number that assumes a suppressor at the connector.

Where this order code fits

It is the default fault tolerant part on 5 V comfort networks and on boards built before 3.3 V controllers arrived in body electronics. Boards weighing one CAN transceiver against another start from our CAN Bus Transceiver Selection page, and boards replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Can TJA1055T be driven by a 3.3 V microcontroller? Not reliably. Its input thresholds and its 40 to 160 microamp TXD current belong to 5 V logic, and the 3 V code exists for that reason.

Are RXD and ERR open drain on this code? No, they are push-pull here. The /3 code is the one with open drain outputs, so pull-ups fitted for that part must be removed.

What is the maximum data rate? 125 kBd, which is the fault tolerant CAN rate. This part is not a high speed transceiver and cannot be used on a 500 kbit/s bus.

SUPERB holds and sources NXP interface lines including this order code for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated. When a line is changing, the Supplier Quality Audit page sets out the checks that keep a substitute from failing on the bench.